94 resultados para frontal sinus
Resumo:
OBJECTIVE: The biventricular pacing (BVP) approach has good results in the treatment of congestive heart failure (CHF) in patients (pts) with disorders of intraventricular conduction. METHODS: We have applied BVP to 28 pts, with left ventricular pacing using minitoracotomy in 3 pts and the transvenous aproach via coronary sinus in 25 pts. The mean duration of the QRS complexes was 187 ms, in the presence of the left branch block in 22 pts, and right branch block + divisional hemiblock in 6 pts. All pts had been considerated candidates to cardiac transplantation, and were under optimized drug therapy. Sixteen pts were in Functional Class (NYHA) IV, and 12 in class III. The ejection fraction varied from 22 to 46% (average = 34%). The pacing mode employed was biventricular triple-chamber in 22 pts, and bi-ventricular dual-chamber in 6 pts (one with ICD). RESULTS: The pts were followed up for a period that ranged from 10 days to 14 months (mean 5 months). All pts presented clinical improvement after implant, chaging the NYHA Functional Class at the end of follow-up to Class I (9pts), Class II (10 pts) and Class III (6 pts). The initial mean ejection fraction have-raised to 37%. Two pts died suddenly. One patient died due to a pulmonary fungal infection. CONCLUSION: Ventricular resynchronization through BVP, improved significantly the Functional Class and, therefore, the quality of life. Assessments of myocardial function acutely performed do not reflect the clinical improvement observed.
Resumo:
OBJECTIVE: To compare immediate and late results in patients with or without fenestration who underwent cavopulmonary anastomosis so that we could assess the efficiency of the technique. METHODS: Sixty-two patients underwent surgery between 1988 and 1999, 41 with fenestration (group I -G I) and 21 without fenestration (group II -G II). Tricuspid atresia was prevalent in group I (23-56%) and single ventricle was prevalent in group II (14-66%). Mean ages at the time of operation were 7.3 years in group I and 7.6 in group II. At late follow-up, mean ages were 10.6 years in group I and 12.8 years in group II. RESULTS: Immediate and late mortality were 7.3% in G-I and 4.7% in G-II. Significant pleural effusion occurred in 41.4% of G-I patients and in 23.8% of G-II patients. Significant pericardial effusion occurred in 29.2% and 14.2%, respectively, in groups I and II. Central venous pressure was greater in G-II, 17.7 cm in H2O, as opposed to 15 cm in G-I. Hospital stay was similar between the groups, 26.3 and 21.8 days, respectively. Cyanosis and arterial insaturation occurred in 5 patients, and 4 patients were in functional class II, all from G-I. At late follow-up, 58 (93.5%) were in functional class I. Sinus rhythm was present in 94%, and pulmonary perfusion was similar in both groups. Eleven patients who underwent spirometry had good tolerance to physical effort. CONCLUSION: Atrial fenestration did not improve the immediate or late follow-up of patients who underwent cavopulmonary anastomosis, and is, therefore, dispensable.
Resumo:
OBJECTIVE: To assess the occurrence of late thromboembolism after surgical repair of chronic atrial fibrillation (AF) simultaneously with repair of mitral valve using the Cox-Maze procedure. METHODS: 69 patients underwent Cox 3 procedure, with no cryoablation simultaneously with mitral valvuloplasty or prosthesis. Mean age was 49.9±13.2 years. Mean follow-up was of 31.7±19 months. Types of lesion were as follows: 33 (48%) stenoses, 23 (33%) insufficiencies, and 13 (19%) double lesions. Procedures were: 64 (93%) valvuloplasties, 3 (4%) biological and 2 (3%) mechanical prosthesis placement. There were 9 (13%) patients with previous systemic embolism and 2 (3%) had left atrial thrombi. RESULTS: Early mortality was 7% and late 1%. 2 patients (3%) were reoperated for mitral placement. At last evaluation, 10 patients (15%), were in AF. The remaining 59 (85%) were either in sinus / atrial rythm (74%) or under pacing (12%). There were no occurrence of early or late, systemic or pulmonary embolism. Permanent anticoagulation was employed in 16 cases, 10 in regular rythm and 6 in AF. The remaining 47 (75%), 2 in AF and 45 in regular rythm, did not receive anticoagulants. CONCLUSIONS: These results are in accordance with others series, where the occurrence of embolism was rare after maze procedure. Permanent systemic anticoagulation seems to be unnecessary in those cases.
Resumo:
OBJECTIVE: To identify the left inferior pulmonary vein as an indirect marker of increased pulmonary flow in congenital heart diseases.METHODS: We carried out a prospective consecutive study on 40 patients divided into 2 groups as follows: G1 - 20 patients diagnosed with congenital heart disease and increased pulmonary flow; G2 (control group) - 20 patients who were either healthy or had congenital heart disease with decreased or normal pulmonary flow. We obtained the velocity-time integral of the left inferior pulmonary vein flow, excluding the "reverse A" wave, with pulsed Doppler echocardiography.RESULTS: In G1, 19 out of the 20 patients had well-identified dilation of the left inferior pulmonary vein. No G2 patient had dilation of the left inferior pulmonary vein. Dilation of the left inferior pulmonary vein in conditions of increased pulmonary flow had sensitivity of 95%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 95% (1 false-negative case). The integral of time and velocity of the pulmonary venous flow obtained with pulsed Doppler echocardiography was greater in the G1 patients (G1=25.0±4.6 cm versus G2=14.8±2.1 cm, p=0.0001).CONCLUSION: The identification of dilation of the left inferior pulmonary vein suggests the presence of congenital heart disease with increased pulmonary flow. This may be used as an indirect sign of increased flow, mainly in malformations of difficult diagnosis, such as atrial septal defects of the venous sinus or coronary sinus type.
Resumo:
OBJECTIVE: Analyze the dromotropic disturbances (vector-electrocardiographic), and the possible anatomic causes, provoked by selective alcohol injection in the septal branch, for percutaneous treatment, of obstructive hypertrophic cardiomyopathy. METHODS: Ten patients with a mean age of 52.7 years underwent percutaneous septal ablation (PTSA) from october 1998; all in functional class III/IV). Twelve-lead electrocardiogram was performed prior to and during PTSA, and later electrocardiogram and vectorcardiogram according to Frank's method. The patients were followed up for 32 months. RESULTS: On electrocardiogram (ECG) prior to PTSA all patients had sinus rhythm and left atrial enlargement, 8 left ventricular hypertrophy of systolic pattern. On ECG immediately after PTSA, 8 had complete right bundle-branch block; 1 transient total atrioventricular block; 1 alternating transient bundle-branch block either right or hemiblock. On late ECG 8 had complete right bundle-branch block confirmed by vectorcardiogram, type 1 or Grishman. CONCLUSION: Septal fibrosis following alcohol injection caused a predominance of complete right bundle-branch block, different from surgery of myotomy/myectomy.
Resumo:
OBJECTIVE: To assess the clinical, electrocardiographic, and electrophysiologic characteristics of patients (pt) with intra-His bundle block undergoing an electrophysiologic study (EPS). METHODS: We analyzed the characteristics of 16 pt with second-degree atrioventricular block and symptoms of syncope or dyspnea, or both, undergoing conventional EPS. RESULTS: Intra-His bundle block was documented in 16 pt during an EPS. In 15 (94%) pt, the atrioventricular block was recorded in sinus rhythm; 4 (25%) pt had intra-His Wenckebach phenomenon, which correlated with Mobitz I (MI) atrioventricular block on the electrocardiogram. Seven (44%) pt had 2:1 atrioventricular block, 2 of whom were asymptomatic (12.5%). One (6%) pt had intra- and infra-His bundle block. Clinically, 11 (68%) pt had syncope or presyncope, 3 (18%) had dyspnea on exertion, and 2 (12.5%) were asymptomatic. Eight (50%) pt had bundle-branch block as follows: 4 (25%) pt had left bundle-branch block, and 4 (25%) had right bundle-branch block. Left anterosuperior divisional block was observed in 3 pt (19%), 2 of whom with associated right bundle-branch block. CONCLUSION: Intra-His bundle block was observed in 11% of the pt with second-degree atrioventricular block, syncope or presyncope, or both, it being the most frequent clinical presentation. Intra-His bundle block was more common in the elderly (> 60 years) and among females. The most frequent electrocardiographic presentations were second-degree Mobitz I or type 2:1 atrioventricular block.
Resumo:
OBJECTIVE: To determine whether recording of the activation potential may be used as an isolated criterion to guide catheter ablation of atriofascicular Mahaim fibers. METHODS: We studied 6 patients (5 females, mean age of 26±7.3 years) with paroxysmal tachycardias with a wide QRS complex, whose electrophysiological study diagnosed atriofascicular Mahaim fibers. Mapping and catheter ablation were performed in sinus rhythm, guided only by the recording of the activation potential of the fiber. RESULTS: Efficacy in ablation was achieved in all patients. The fibers were located in the right lateral region of the tricuspid ring in 3 patients, right posterolateral region in 2, and right anterolateral region in 1. A mean of 5.3±3 radiofrequency applications was performed. The mean fluoroscopy time was 46.6±25 minutes, and the mean duration of the procedure was 178.6±108 minutes. No complication occurred. In a mean 20-month follow-up, all patients were asymptomatic and receiving no antiarrhythmic drugs. CONCLUSION: Catheter ablation of Mahaim fibers may be performed with good safety and efficacy by mapping the activation potential of the tricuspid ring in sinus rhythm.
Resumo:
OBJECTIVE: To characterize the cardiac electrophysiologic effects of cocaine. METHODS: In 8 dogs (9-13 kg), electrophysiologic parameters and programmed stimulation were undertaken using transvenous catheters at baseline, and after cocaine intravenous infusion (12 mg/kg bolus followed by 0.22 mg/kg/min for 25 minutes). RESULTS: Cocaine plasma levels (n=5) rose to 6.73± 0.56 mg/mL. Cocaine did not affect sinus cycle length and arterial pressure. Cocaine prolonged P wave duration (54±6 vs 73±4 ms, P<0.001), PR interval (115±17 vs 164±15 ms, P<0.001), QRS duration (62±10 vs 88±14 ms, P<0.001), and QTc interval (344±28 vs 403±62 ms, P=0.03) but not JT interval (193±35 vs 226±53 ms, NS). Cocaine prolonged PA (9±6 vs 23±8 ms, P<0.001), AH (73±16 vs 92±15 ms; P=0.03), and HV (35±5 vs 45±3ms; P<0.001) intervals and Wenckebach point (247±26 vs 280±28 ms, P=0.04). An increase occurred in atrial (138±8 vs 184± 20 ms; P<0.001) and ventricular (160±15 vs 187±25 ms; P=0.03) refractoriness at a cycle length of 300 ms. Atrial arrhythmias were not induced in any dog. Ventricular fibrillation (VF) was induced in 2/8 dogs at baseline and 4/8 dogs after cocaine. CONCLUSION: High doses of cocaine exert significant class I effects and seem to enhance inducibility of VF but not of atrial arrhythmias.
Resumo:
OBJECTIVE: To investigate the morphometric and topographic aspects of coronary ostia, correlating them with the aortic leaflets. METHODS: Fifty-one hearts with the great vessels attached were analyzed in this study. The ascending aorta was transversally sectioned 1 cm above the commissures of the aortic leaflets. The right and left coronary ostia were analyzed, as were the distances from these ostia to the bottom of the aortic sinuses and to the commissures of the aortic leaflets. RESULTS: The left coronary ostium was located below the intercommissural line in 42% of cases, above that line in 40% of cases, and at the level of that line in 18% of cases. The mean distance from the left coronary ostium to the bottom of the corresponding sinus was 12.6±2.61 mm. The right coronary ostium was located below the intercommissural line in 60% of cases, above that line in 28% of cases, and at the level of that line in 12% of cases. The mean distance from the right coronary ostium to the bottom of the corresponding aortic sinus was 13.2±2.64 mm. The mean diameters of the left and right coronary ostia were 4.75±0.93 mm and 3.46±0.94 mm, respectively. The mean diameters of the juxtamural portion of the left and right coronary arteries were 3.75±0.79 mm and 2.9±0.73 mm, respectively. In one case, both ostia were located in the left coronary sinus. CONCLUSION: The left coronary ostium may be located either above or below the intercommissural line. The right coronary ostium is predominantly located below the intercommissural line. The coronary ostia have reduced diameters as compared with the juxtamural diameters of their respective coronary arteries.
Resumo:
OBJECTIVE: To identify the electrocardiographic changes and their associations with metabolic and electrolytic changes in female alcoholics. METHODS: The study comprised 44 female alcoholics with no apparent physical disorder. They underwent the following examinations: conventional electrocardiography; serologic tests for syphilis, Chagas' disease, and hepatitis B and C viruses; urinary pregnancy testing; hematimetric analysis; biochemical measurements of albumin, fibrinogen, fasting and postprandial glycemias, lipids, hepatic enzymes, and markers for tissue necrosis and inflammation. RESULTS: Some type of electrocardiographic change was identified in 33 (75%) patients. In 17 (38.6%) patients, more than one of the following changes were present: prolonged QTc interval in 24 (54.5%), change in ventricular repolarization in 11(25%), left ventricular hypertrophy in 6 (13.6%), sinus bradycardia in 4 (9.1%), sinus tachycardia in 3 (6.8%), and conduction disorder in 3 (6.8%). The patients had elevated mean serum levels of creatine phosphokinase, aspartate aminotransferases, and gamma glutamyl transferase, as well as hypocalcemia and low levels of total cholesterol and LDL-cholesterol. The patients with altered electrocardiograms had a more elevated age, a lower alcohol consumption, hypopotassemia, and significantly elevated levels of triglycerides, postprandial glucose, sodium and gamma glutamyl transferase than those with normal electrocardiograms. The opposite occurred with fasting glycemia, magnesium, and alanine aminotransferase. CONCLUSION: The electrocardiographic changes found were prolonged QTc interval, change in ventricular repolarization, and left ventricular hypertrophy. Patients with normal and abnormal electrocardiograms had different metabolic and electrolytic changes.
Stent de sustentação de eletrodo de seio coronariano na ressincronização cardíaca: relato de 5 casos
Resumo:
MSM, homem, 69 anos, procurou atendimento médico por dor em dorso esquerdo e membro inferior direito. A radiografia de tórax revelou alargamento do mediastino. Estava em observação quando apresentou rebaixamento da consciência e choque. Foi observado enfisema subcutâneo em hemitórax esquerdo e abolição do murmúrio vesicular em base do mesmo pulmão. Foi feita a intubação orotraqueal e realizada drenagem de hemitórax esquerdo, com saída de líquido serossanguinolento. O ecocardiograma revelou ventrículo esquerdo (D/S): 44/29 mm; septo 12 mm; parede posterior 13 mm; discreta dilatação em raiz da aorta, presença de lâmina de dissecção e hematoma periaórtico. As valvas e pericárdio eram normais. O paciente foi transferido para o InCor. O exame físico (21 out 2004: 10h45) revelou paciente sedado, com intubação orotraqueal, com palidez cutânea, frequência cardíaca 90 bpm, pressão arterial 130 x 80 mmHg, drenagem torácica sanguinolenta do dreno tórax. Eletrocardiograma - frequência 90 bpm, ritmo sinusal, baixa voltagem no plano frontal e diminuição de voltagem em derivações esquerdas (fig. 1). A tomografia revelou enfisema subcutâneo bilateral, aorta torácica com contornos imprecisos na sua porção descendente (da artéria subclávia até porção média), colapso do pulmão esquerdo e grande coleção de características hemáticas em mesmo hemitórax e no mediastino médio e posterior. Pequeno pneumotórax à direita; pequeno derrame pleural à direita com alterações do parênquima subjacente. A análise do coração foi prejudicada pela presença do hemotórax. Durante a realização de tomografia apresentou ausência de pulsos, midríase, com assistolia, sem resposta às manobras de ressuscitação e faleceu (21 out 2011; 15h).
Resumo:
FUNDAMENTOS: O bloqueio do ramo esquerdo (BRE) e a presença de disfunção sistólica são as principais indicações de terapia de ressincronização cardíaca (TRC). A dissincronia ventricular mecânica pela ecocardiografia pode ajudar a identificar pacientes responsivos à TRC. O BRE pode mostrar diferentes padrões em sua morfologia. OBJETIVO: Comparar a prevalência de dissincronia mecânica em diferentes padrões de BRE em pacientes com disfunção sistólica esquerda. MÉTODOS: Analisaram-se 48 pacientes com fração de ejeção (FE) < 40% e BRE referidos consecutivamente para análise de dissincronia. Foram realizados ecocardiograma convencional e análise da dissincronia mecânica, interventricular e intraventricular, por 10 conhecidos métodos, usando modo M, Doppler e Doppler tecidual, sozinhos ou combinados. A morfologia do BRE foi categorizada pelo desvio esquerdo do eixo no plano frontal e duração de QRS > 150 ms. RESULTADOS: Eram 24 homens, com idade 60 ± 11 anos e FEVE de 29 ± 7%. Trinta e dois apresentavam QRS > 150 ms, e 22, ECG eixo entre -30º e +90º. A dissincronia interventricular foi identificada em 73% dos pacientes e a intraventricular em valores entre 37-98%. Portadores de QRS > 150 ms apresentaram maiores dimensões do átrio e ventrículo esquerdos, e menor FE (p < 0,05), e o desvio esquerdo do eixo associou-se a pior função diastólica e maior diâmetro atrial. A presença de dissincronia mecânica interventricular e intraventricular (10 métodos) foi semelhante entre os diferentes padrões de BRE (p = ns). CONCLUSÃO: Nos dois diferentes padrões eletrocardiográficos de BRE analisados, não foram observadas diferenças em relação à presença de dissincronia mecânica.
Resumo:
Background:The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown.Objective:Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease.Methods:Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant.Results:Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3.95; CI 0.99-15.82; p = 0.052). The EF also emerged as a predictor of induction of VT / VF: for each point increase in EF, there was a 4% reduction in the rate of sustained ventricular arrhythmia on EPS.Conclusions:Changes in the QRS-T angle and decreases in EF were associated with an increased risk of induction of VT / VF on EPS.
Resumo:
Background:Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process.Objective:To evaluate the impact of AF ablation on estimated LV filling pressure.Methods:A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation.Results:One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001).Conclusion:Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.