92 resultados para dobutamine stress testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare blood pressure response to dynamic exercise in hypertensive patients taking trandolapril or captopril. METHODS: We carried out a prospective, randomized, blinded study with 40 patients with primary hypertension and no other associated disease. The patients were divided into 2 groups (n=20), paired by age, sex, race, and body mass index, and underwent 2 symptom-limited exercise tests on a treadmill before and after 30 days of treatment with captopril (75 to 150 mg/day) or trandolapril (2 to 4 mg/day). RESULTS: The groups were similar prior to treatment (p<0.05), and both drugs reduced blood pressure at rest (p<0.001). During treatment, trandolapril caused a greater increase in functional capacity (+31%) than captopril (+17%; p=0.01) did, and provided better blood pressure control during exercise, observed as a reduction in the variation of systolic blood pressure/MET (trandolapril: 10.7±1.9 mmHg/U vs 7.4±1.2 mmHg/U, p=0.02; captopril: 9.1±1.4 mmHg/U vs 11.4±2.5 mmHg/U, p=0.35), a reduction in peak diastolic blood pressure (trandolapril: 116.8±3.1 mmHg vs 108.1±2.5 mmHg, p=0.003; captopril: 118.2±3.1 mmHg vs 115.8±3.3 mmHg, p=0.35), and a reduction in the interruption of the tests due to excessive elevation in blood pressure (trandolapril: 50% vs 15%, p=0.009; captopril: 50% vs 45%, p=0.32). CONCLUSION: Monotherapy with trandolapril is more effective than that with captopril to control blood pressure during exercise in hypertensive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety, feasibility, and the results of early exercise testing in patients with chest pain admitted to the emergency room of the chest pain unit, in whom acute myocardial infarction and high-risk unstable angina had been ruled out. METHODS: A study including 1060 consecutive patients with chest pain admitted to the emergency room of the chest pain unit was carried out. Of them, 677 (64%) patients were eligible for exercise testing, but only 268 (40%) underwent the test. RESULTS: The mean age of the patients studied was 51.7±12.1 years, and 188 (70%) were males. Twenty-eight (10%) patients had a previous history of coronary artery disease, 244 (91%) had a normal or unspecific electrocardiogram, and 150 (56%) underwent exercise testing within a 12-hour interval. The results of the exercise test in the latter group were as follows: 34 (13%) were positive, 191 (71%) were negative, and 43 (16%) were inconclusive. In the group of patients with a positive exercise test, 21 (62%) underwent coronary angiography, 11 underwent angioplasty, and 2 underwent myocardial revascularization. In a univariate analysis, type A/B chest pain (definitely/probably anginal) (p<0.0001), previous coronary artery disease (p<0.0001), and route 2 (patients at higher risk) correlated with a positive or inconclusive test (p<0.0001). CONCLUSION: In patients with chest pain and in whom acute myocardial infarction and high-risk unstable angina had been ruled out, the exercise test proved to be feasible, safe, and well tolerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1) or positive (G2) for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%). During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016). The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022) and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively). Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Stress is associated with cardiovascular diseases. Objective: This study aimed at assessing whether chronic stress induces vascular alterations, and whether these modulations are nitric oxide (NO) and Ca2+ dependent. Methods: Wistar rats, 30 days of age, were separated into 2 groups: control (C) and Stress (St). Chronic stress consisted of immobilization for 1 hour/day, 5 days/week, 15 weeks. Systolic blood pressure was assessed. Vascular studies on aortic rings were performed. Concentration-effect curves were built for noradrenaline, in the presence of L-NAME or prazosin, acetylcholine, sodium nitroprusside and KCl. In addition, Ca2+ flux was also evaluated. Results: Chronic stress induced hypertension, decreased the vascular response to KCl and to noradrenaline, and increased the vascular response to acetylcholine. L-NAME blunted the difference observed in noradrenaline curves. Furthermore, contractile response to Ca2+ was decreased in the aorta of stressed rats. Conclusion: Our data suggest that the vascular response to chronic stress is an adaptation to its deleterious effects, such as hypertension. In addition, this adaptation is NO- and Ca2+-dependent. These data help to clarify the contribution of stress to cardiovascular abnormalities. However, further studies are necessary to better elucidate the mechanisms involved in the cardiovascular dysfunction associated with stressors. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physical stress echocardiography is an established methodology for diagnosis and risk stratification of coronary artery disease in patients with physical capacity. In obese (body mass index ≥ 30 kg/m2) the usefulness of pharmacological stress echocardiography has been demonstrated; however, has not been reported the use of physical stress echocardiography in this growing population group. Objective: To assess the frequency of myocardial ischemia in obese and non-obese patients undergoing physical stress echocardiography and compare their clinical and echocardiographic differences. Methods: 4,050 patients who underwent treadmill physical stress echocardiography were studied according to the Bruce protocol, divided into two groups: obese (n = 945; 23.3%) and non-obese (n = 3,105; 76.6%). Results: There was no difference regarding gender. Obese patients were younger (55.4 ± 10.9 vs. 57.56 ± 11.67) and had a higher frequency of hypertension (75.2% vs. 57, 2%; p < 0.0001), diabetis mellitus (15.2% vs. 10.9%; p < 0.0001), dyslipidemia (59.5% vs 51.9%; p < 0.0001), family history of coronary artery disease (59.3% vs. 55.1%; p = 0.023) and physical inactivity (71.4% vs. 52.9%, p < 0.0001). The obese had greater aortic dimensions (3.27 vs. 3.14 cm; p < 0.0001), left atrium (3.97 vs. 3.72 cm; p < 0.0001) and the relative thickness of the ventricule (33.7 vs. 32.8 cm; p < 0.0001). Regarding the presence of myocardial ischemia, there was no difference between groups (19% vs. 17.9%; p = 0.41). In adjusted logistic regression, the presence of myocardial ischemia remained independently associated with age, female gender, diabetes and hypertension. Conclusion: Obesity did not behave as a predictor of the presence of ischemia and the physical stress echocardiography. The application of this assessment tool in large scale sample demonstrates the feasibility of the methodology, also in obese.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Prolonged aerobic exercise, such as running a marathon, produces supraphysiological stress that can affect the athlete's homeostasis. Some degree of transient myocardial dysfunction ("cardiac fatigue") can be observed for several days after the race. Objective: To verify if there are changes in the cardiopulmonary capacity, and cardiac inotropy and lusitropy in amateur marathoners after running a marathon. Methods: The sample comprised 6 male amateur runners. All of them underwent cardiopulmonary exercise testing (CPET) one week before the São Paulo Marathon, and 3 to 4 days after that race. They underwent echocardiography 24 hours prior to and immediately after the marathon. All subjects were instructed not to exercise, to maintain their regular diet, ingest the same usual amount of liquids, and rest at least 8 hours a day in the period preceding the CPET. Results: The athletes completed the marathon in 221.5 (207; 250) minutes. In the post-marathon CPET, there was a significant reduction in peak oxygen consumption and peak oxygen pulse compared to the results obtained before the race (50.75 and 46.35 mL.kg-1 .min-1; 19.4 and 18.1 mL.btm, respectively). The echocardiography showed a significant reduction in the s' wave (inotropic marker), but no significant change in the E/e' ratio (lusitropic marker). Conclusions: In amateur runners, the marathon seems to promote changes in the cardiopulmonary capacity identified within 4 days after the race, with a reduction in the cardiac contractility. Such changes suggest that some degree of "cardiac fatigue" can occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drosophila willistoni (Sturtevant, 1916) is a species of the willistoni group of Drosophila having wide distribution from the South of USA (Florida) and Mexico to the North of Argentina. It has been subject of many evolutionary studies within the group, due to its considerable ability to successfully occupy a wide range of environments and also because of its great genetic variability expressed by different markers. The D. willistoni 17A2 strain was collected in 1991 in the state of Rio Grande do Sul, Brazil (30°05'S, 51°39'W), and has been maintained since then at the Drosophila laboratory of UFRGS. Different to the other D. willistoni strains maintained in the laboratory, the 17A2 strain spontaneously produced mutant males white-like (white eyes) and sepia-like (brown eyes) in stocks held at 17°C. In order to discover if this strain is potentially hypermutable, we submitted it to temperature stress tests. Eighteen isofemale strains were used in our tests and, after the first generation, all the individuals produced in each strain were maintained at 29°C. Different phenotype alterations were observed in subsequent generations, similar to mutations already well characterized in D. melanogaster (white, sepia, blistered and curly). In addition, an uncommon phenotype alteration with an apparent fusion of the antennae was observed, but only in the isofemale line nº 31. This last alteration has not been previously described as a mutation in the D. melanogaster species. Our results indicate that the D. willistoni 17A2 strain is a candidate for hypermutability, which presents considerable cryptic genetic variability. Different factors may be operating for the formation of this effect, such as the mobilization of transposable elements, effect of inbreeding and alteration of the heat-shock proteins functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is described which permits to determine in vivo an in a short period of time (4-6 hours) the sensitivity of T. cruzo strains to known active chemotherapeutic agents. By using resistant- and sensitive T. cruzi stains a fairly good correlation was observed between the results obtained with this rapid method (which detects activity against the circulating blood forms) and those obtained with long-term schedules which involve drug adminstration for at least 20 consecutive days and a prolonged period of assessment. This method may be used to characterize susceptibility to active drugs used clinically, provide infomation on the specific action against circulating trypomastigotes and screen active compounds. Differences in the natural susceptibility of Trypanosoma cruzi strains to active drugs have been already reported using different criteria, mostly demanding long-term study of the animal (Hauschka, 1949; Bock, Gonnert & Haberkorn, 1969; Brener, Costa & Chiari, 1976; Andrade & Figueira, 1977; Schlemper, 1982). In this paper we report a method which detects in 4-6 hours the effect of drugs on bloodstream forms in mice with established T. cruzi infections. The results obtained with this method show a fairly good correlation with those obtained by prolonged treatment schedules used to assess the action of drugs in experimental Chagas' disease and may be used to study the sensitivity of T. cruzi strains to active drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

South American Aoutus an d Saimiri monkeys, which are susceptible to infection with human malarias, have been used to develop models for the testing of huma malaria vaccines. Studies indicate that blood-stage and sporozoite vaccines can be tested in these monkeys using appropriate strains of parasites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antibiotic susceptibilities of Neisseria gonorrhoeae isolates obtained from patients attending a clinic for sexually transmitted diseases in Tucumán, Argentina, were determined by the agar dilution method (MIC). 3.5% of the isolates produced ²-lactamase. A total of 96.5% of ²-lactamase negative isolates tested were susceptible to penicillin (MIC < 2 µgml-1); 14.03% of the tested isolates were resistant to tetracycline (MIC < 2 µgml-1), and 98% of the tested isolates were susceptible to spectinomycin (MIC < 64 µgml-1). The MICs for 95% of the isolates, tested for other drugs were: < 2 µgml-1 for cefoxitin, < 0.06 µgml-1 for cefotaxime, < 0.25 µgml-1 for norfloxacin, < 10 µgml-1 for cephaloridine, < 10 µgml-1 for cephalexin, and < 50 µgml-1 for kanamycin. Antibiotic resistance among N. gonorrhoeae isolates from Tucumán, Argentina, appeared to be primarily limited to penicillin and tetracycline, which has been a general use against gonorrhoeae in Tucumán since 1960. Periodic monitoring of the underlying susceptibility profiles of the N. gonorrhoeae strains prevalent in areas of frequent transmission may provide clues regarding treatment options and emerging of drug resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From March 1996 to August 1997, a study was carried out in a malaria endemic area of the Brazilian Amazon region. In vivo sensitivity evaluation to antimalarial drugs was performed in 129 patients. Blood samples (0.5 ml) were drawn from each patient and cryopreserved to proceed to in vitro studies. In vitro sensitivity evaluation performed using a radioisotope method was carried out with the cryopreserved samples from September to December 1997. Thirty-one samples were tested for chloroquine, mefloquine, halofantrine, quinine, arteether and atovaquone. Resistance was evidenced in 96.6% (29/30) of the samples tested for chloroquine, 3.3% (1/30) for quinine, none (0/30) for mefloquine and none for halofantrine (0/30). Overall low sensitivity was evidenced in 10% of the samples tested for quinine, 22.5% tested for halofantrine and in 20% tested for mefloquine. Means of IC 50 values were 132.2 (SD: 46.5) ng/ml for chloroquine, 130.6 (SD: 49.6) ng/ml for quinine, 3.4 (SD: 1.3) ng/ml for mefloquine, 0.7 (SD: 0.3) ng/ml for halofantrine, 1 (SD: 0.6) ng/ml for arteether and 0.4 (SD: 0.2) ng/ml for atovaquone. Means of chloroquine IC 50 of the tested samples were comparable to that of the chloroquine-resistant strain W2 (137.57 ng/ml) and nearly nine times higher than that of the chloroquine-sensitive strain D6 (15.09 ng/ml). Means of quinine IC 50 of the tested samples were 1.7 times higher than that of the low sensitivity strain W2 (74.84 ng/ml) and nearly five times higher than that of the quinine-sensitive strain D6 (27.53 ng/ml). These results disclose in vitro high resistance levels to chloroquine, low sensitivity to quinine and evidence of decreasing sensitivity to mefloquine and halofantrine in the area under evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the correlation between proportion method with mycobacteria growth indicator tube (MGIT) and E-test for Mycobacterium tuberculosis. Forty clinical isolates were tested. MGIT and E-test with the first line antituberculous drugs correlated with the proportion method. Our results suggested that MGIT and E-test methods can be routinely used instead of the proportion method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.