118 resultados para balloon catheter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE - This analysis was undertaken to determine the composite incidence of cumulative adverse events (death, reinfarction, disabling stroke, and target vessel revascularization) at the end of the first year after acute myocardial infarction, in diabetic patients who underwent coronary stenting or primary coronary balloon angioplasty. METHODS - From the STENT PAMI trial, we analyzed the 6-month angiographic and 1-year clinical outcomes of 135 diabetic (112, noninsulin dependent) patients who underwent the randomization process of the trial and compared them with 758 nondiabetic patients. RESULTS - Coronary stenting did not significantly reduce the primary composite clinical end point when compared with PTCA (20 vs. 30%, p=0.2). A significant benefit from stenting was observed in patients with noninsulin dependent diabetes, with a trend toward a lesser need for new revascularization procedures (10 vs. 21%, p<.001), with a significant reduction in the primary composite clinical end point at 1 year (12 vs. 28%, p=. 04). At 6 months, the restenosis rate were significantly reduced only in nondiabetic patients (18 vs. 33%, p<. 001). Diabetic patients had the same restenosis rate (38%) either with stenting or balloon PTCA. CONCLUSIONS - Coronary Stenting in diabetics noninsulin dependent offered a significant reduction in the composite incidence of major clinical adverse events compared with balloon PTCA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To verify the results after the performance of primary coronary angioplasty in Brazil in the last 4 years. METHODS: During the first 24 hours of acute myocardial infarction onset, 9,434 (12.2%) patients underwent primary PTCA. We analyzed the success and occurrence of major in-hospital events, comparing them over the 4-year period. RESULTS: Primary PTCA use increased compared with that of all percutaneous interventions (1996=10.6% vs. 2000=13.1%; p<0.001). Coronary stent implantation increased (1996=20% vs. 2000=71.9%; p<0.001). Success was greater (1998=89.5% vs. 1999=92.5%; p<0.001). Reinfarction decreased (1998=3.9% vs. 99=2.4% vs. 2000=1.5%; p<0.001) as did emergency bypass surgery (1996=0.5% vs. 2000=0.2%; p=0.01). In-hospital deaths remained unchanged (1996=5.7% vs. 2000=5.1%, p=0.53). Balloon PTCA was one of the independent predictors of a higher rate of unsuccessful procedures (odds ratio 12.01 [CI=95%] 1.58-22.94), and stent implantation of lower mortality rates (odds ratio 4.62 [CI=95%] 3.19-6.08). CONCLUSION: The success rate has become progressively higher with a significant reduction in reinfarction and urgent bypass surgery, but in-hospital death remains nearly unchanged. Coronary stenting was a predictor of a lower death rate, and balloon PTCA was associated with greater procedural failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the impact of the use, prior to the procedure, of injectable diltiazem to prevent complications. METHODS: Between September 2000 and July 2001, 50 patients underwent transradial coronary angiography and were randomized to receive placebo (GI) or diltiazem (GII) through a catheter inserted into the radial artery. All patients received isosorbide mononitrate. Ultrasound analyses of the radial artery were performed before examination, 30 minutes afterwards, and 7 days afterwards to evaluate the flow, the diameter, and the artery output. RESULTS: The radial artery diameter of GI was 2.4± 0.5 mm before the procedure and 2.3±0.5 mm after 30 minutes (NS), whereas in GII the diameter was 2.2±0.3 mm before the examination and 2.5±0.4 mm 30 minutes after it (P<0.001). Radial artery output in group 1 was 7.3±5.l2 mL/min before the examination and 6.1±3.5 mL/min 30 minutes after the examination (NS), and GII had an increase of 5.9±2.5 mL/min before examination to 9.05± 7.78 mL/min after the examination (P=0.04). Complications (spasm, occlusion, and partial obstruction) occurred in 4 patients (17.4%) in GI and did not occur in GII (P=0.04). CONCLUSION: The study suggests a decrease in vascular complications through the transradial access for coronary angiography with the use of diltiazem as an antispasmodic drug, resulting in the significant increase in the diameter of the radial artery and radial artery output.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systemic arterial hypertension (SAH) is considered to be the greatest risk factor for the development of neuro-cardiovascular pathologies, thus constituting a severe Public Health issue in the world. The Low-Level Laser Therapy (LLLT), or laser therapy, activates components of the cellular structure, therefore converting luminous energy into photochemical energy and leading to biophysical and biochemical reactions in the mitochondrial respiratory chain. The LLLT promotes cellular and tissue photobiomodulation by means of changes in metabolism, leading to molecular, cellular and systemic changes. The objective of this study was to analyze the action of low-level laser in the hemodynamic modulation of spontaneously hypertensive rats, in the long term. Animals (n = 16) were randomly divided into the Laser Group (n = 8), which received three weekly LLLT irradiations for seven weeks, and into the Sham Group (n = 8), which received three weekly simulations of laser for seven weeks, accounting for 21 applications in each group. After seven weeks, animals were cannulated by the implantation of a catheter in the left carotid artery. On the following day, the systemic arterial pressure was recorded. The Laser Group showed reduced levels of mean blood pressure, with statistically significant reduction (169 ± 4 mmHg* vs. 182 ± 4 mmHg from the Sham Group) and reduced levels of diastolic pressure (143 ± 4 mmHg* vs. 157 ± 3 mmHg from the Sham Group), revealing a 13 and 14 mmHg decrease, respectively. Besides, there was a concomitant important decline in heart rate (312 ± 14 bpm vs. 361 ± 13 bpm from the Sham Group). Therefore, laser therapy was able to produce hemodynamic changes, thus reducing pressure levels in spontaneously hypertensive rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process.Objective:To evaluate the impact of AF ablation on estimated LV filling pressure.Methods:A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation.Results:One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001).Conclusion:Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Radiofrequency ablation is the standard non-pharmacological treatment for arrhythmias in pediatric patients. However, arrhythmias and their associated causes have particular features in this population.Objective:To analyze the epidemiological characteristics and findings of electrophysiological diagnostic studies and radiofrequency ablations in pediatric patients referred to the Electrophysiology Unit at Instituto de Cardiologia do Rio Grande do Sul, in order to characterize the particularities of this population.Methods:Cross-sectional study with 330 electrophysiological procedures performed in patients aged less than 20 years between June 1997 and August 2013.Results:In total, 330 procedures (9.6% of the overall procedures) were performed in patients aged less than 20 years (14.33 ± 3.25 years, age range 3 months to 19 years), 201 of which were males (60.9%). A total of 108 (32.7%) electrophysiological diagnostic studies were performed and of these, 48.1% showed abnormal findings. Overall, 219 radiofrequency ablations were performed (66.3%) with a success rate of 84.8%. The presence of an accessory pathway was the most prevalent finding, occurring in 158 cases (72.1%), followed by atrioventricular nodal reentrant tachycardia (16.8%), typical atrial flutter (3.1%) and extrasystoles originating from the right ventricular outflow tract (2.7%). Three patients developed complications during ablation (1.4%). Among congenital heart diseases, which occurred in 51 (15.4%) patients, atrial sept defect was the most frequent (27.4%), followed by ventricular sept defect (25.4%) and Ebstein's anomaly (17.6%).Conclusion:Electrophysiological study and radiofrequency ablation are effective tools for diagnosis and treatment of arrhythmias in the pediatric population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle.Objective:To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation.Methods:Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation.Results:31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred.Conclusion:Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Clinical in-stent restenosis (CISR) is the main limitation of coronary angioplasty with stent implantation. Objective: Describe the clinical and angiographic characteristics of CISR and the outcomes over a minimum follow-up of 12 months after its diagnosis and treatment. Methods: We analyzed in 110 consecutive patients with CISR the clinical presentation, angiographic characteristics, treatment and combined primary outcomes (cardiovascular death, nonfatal acute myocardial infarction [AMI]) and combined secondary (unstable angina with hospitalization, target vessel revascularization and target lesion revascularization) during a minimal follow-up of one year. Results: Mean age was 61 ± 11 years (68.2% males). Clinical presentations included acute coronary syndrome (ACS) in 62.7% and proliferative ISR in 34.5%. CISR was treated with implantation of drug-eluting stents (DES) in 36.4%, Bare Metal Stent (BMS) in 23.6%, myocardial revascularization surgery in 18.2%, balloon angioplasty in 15.5% and clinical treatment in 6.4%. During a median follow-up of 19.7 months, the primary outcome occurred in 18 patients, including 6 (5.5%) deaths and 13 (11.8%) AMI events. Twenty-four patients presented a secondary outcome. Predictors of the primary outcome were CISR with DES (HR = 4.36 [1.44–12.85]; p = 0.009) and clinical treatment for CISR (HR = 10.66 [2.53–44.87]; p = 0.001). Treatment of CISR with BMS (HR = 4.08 [1.75–9.48]; p = 0.001) and clinical therapy (HR = 6.29 [1.35–29.38]; p = 0.019) emerged as predictors of a secondary outcome. Conclusion: Patients with CISR present in most cases with ACS and with a high frequency of adverse events during a medium-term follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention.Objective:To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated.Results:A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001).Conclusion:Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.