195 resultados para Supercritical Fluid Extraction (SFE)
Resumo:
OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.
Resumo:
Solubilization of Schistosoma mansoni antigens was obtained by agitation of adult worms in a 3M KCl solution. The protein contents of the KCl extrats varied from 0.35 to 0.96 mg/ml. Sera from 97 patients with hepatointestinal shistosomiasis and viable eggs in stools from a Brazilian endemic area were studied by immunoelectroomophoresis and Ouchterlony immunodiffusion methods with the KCl extract and with another antigen, obtained by homogenization of adult schistosomes in saline. The rate of positiveness of immunoprecipitation deterctions by immunoelectroomophoresis with the KCl extract was 53.5%. A correlation was verified between methods of detection and extration procedures, resulting in a better association of the extract obtained by agitation in 3M KCl and immunoelectroomophoresis.
Resumo:
In order to evaluate the effect of chaotropic agents on proteoglycan and non-collagenous proteins, chicken xiphoid cartilage was treated with guanidine-HCI and MgCl2 in different concentrations (1M to 5M), and different periods of time (12, 24, 48 and 72hr). The maximum yield of uronic acid was obtained with 3M MgCl2 (73.3 per cent). Concentrations of 4M and 5M of MgCl2 showed that much less uronic acid was removed, 55.3 per cent and 38.1 respectively. Extraction with 3M MgCl2 and 3M guanidine-HCl resulted better efficiency when performed for 48 hr. Analysis by SDS-PAGE of the extracts obtained with guanidine-HCl and MgCl, in different concentrations pointed out that most components are equally removed with the two solvents, showing that the extraction with MgCl2 is an alternative assay to remove non-collagenous proteins from extracellular matrix.
Resumo:
To demonstrate the potential of McCoy cells for the isolation of rabies virus from the cerebrospinal (CSF) fluid of a patient with a diagnosis of rabies, McCoy cells were inoculated with CSF from a patient with a clinical diagnosis of rabies and investigated in terms of morphometric aspect using the JAVA analysis system for the quantification of the increased size of infected cells compared to noninfected cells. The cells were also examined in terms of specific staining for the diagnosis of rabies by the method of Sellers for the observation of intracytoplasmic inclusions and by specific immunofluorescence staining for rabies virus. Infected cells showed changes in cell permeability and morphologic modifications which differed significantly compared to normal cells (P<0.001) when analyzed by the Mann-Whitney and Kruskal-Wallis tests. Intense activity of the endoplasmic reticulum was also observed, as indicated by the presence of intracytoplasmic inclusions visualized by specific staining. The present study demonstrated the isolation of rabies virus from the CSF of a patient with rabies, showing that McCoy cells can be used for the laboratory diagnosis of patients suspected to have rabies.
Resumo:
The purpose of this study was to examine the circulating filarial antigen (CFA) detected by the monoclonal antibody (mAb) Og4C3-ELISA in paired samples of serum and hydrocele fluid from 104 men with hydrocele, living in an endemic area of Wuchereria bancrofti. Nocturnal blood specimens were filtered and examined for microfilariae (MF) and ultrasound was used in order to identify the presence of adult worms (the filaria dance sign - FDS) in the lymphatic vessels of the scrotal area. Four groups were selected according to their parasitological status: group I - 71 MF- and FDS-; group II - 21 MF+ and FDS+; group III - 10 MF- and FDS+ and group IV- 2 MF+ and FDS-. CFA was identified simultaneously (fluid and serum) in 11 (15.5%), 21 (100%), 3 (30%), and 1 (50%) in groups I, II, III, and IV, respectively. In despite of high CFA+ level (antigen Og4C3) units/ml, the Geometrical Mean (GM) = 2696) in the sera of these 36/104 paired samples, when compared to the hydrocele fluid, (GM = 1079), showed a very good correlation between the CFA level in the serum and CFA level in the fluid (r = 0.731). CFA level in the serum of the 23 microfilaremics (groups II and IV) was extremely high (GM = 4189) and was correlated with MF density (r = 0.442). These findings report for the first time the potential alternative use of the hydrocele fluid to investigate CFA using the mAb Og4C3-ELISA.
Resumo:
Paired samples of cerebrospinal fluid (CSF) and serum of 30 patients - 10 with active, 10 with inactive neurocysticercosis (NCC), and 10 control subjects - were evaluated by enzyme-linked immunosorbent assay (ELISA) using two Taenia crassiceps metacestode extracts as antigen in order to detect IgG antibodies. In active NCC, high levels of IgG were detected (p < 0.05). The CSF samples showed 80% (CI 72-88) of reactivity in the saline extract (S) and 90% (CI 84-95) in sodium dodecyl sulphate (SDS) and the serum samples were reactive in 90% (CI 84-95) and 100% (CI 98-100) in the S and SDS antigenic extracts, respectively. The use of the paired samples of CSF and serum in active NCC showed equivalent results suggesting that the serum samples could be used as a screening in those patients whose CSF puncture is counter-indicated.
Resumo:
In this report, we examine the adaptability of commercially available serological kits to detect antibodies markers for viral hepatitis in oral fluid samples. We also assessed the prevalence of hepatitis A, B, and C virus-specific antibodies, and related risk factors for these infectious diseases through sensitivity of the tests in saliva samples to evaluate if oral fluid can be an alternative tool to substitute serum in diagnosis of acute viral hepatitis and in epidemiological studies. One hundred and ten paired serum and saliva specimens from suspect patients of having acute hepatitis were collected to detect antibodies to hepatitis A (total and IgM), hepatitis B (anti-HBs, total anti-HBc and IgM anti-HBc), and hepatitis C (anti-HCV) using commercially available enzyme-linked immunossorbent assay (EIA). In relation to serum samples, oral fluid assay sensitivity and specificity were as follows: 87 and 100% for total anti-HAV, 79 and 100% for anti-HAV IgM, 6 and 95% for anti-HBs, 13 and 100% for total anti-HBc, 100 and 100% for anti-HBc IgM, and 75 and 100% for anti-HCV. The consistency observed between antibodies tests in saliva and expected risk factors for hepatitis A and C suggests that the saliva method could replace serum in epidemiological studies for hepatitis A and C.
Resumo:
The aim of this study was to test if serological distinction between patients with active and inactive neurocysticercosis (NCC), could be accomplished by the recognition of immunodominant peptides in total saline antigenic extract of Taenia solium metacestodes by IgG antibody in cerebrospinal fluid (CSF) and serum paired samples. CSF and serum samples of 10 each, active NCC patients, inactive NCC, and individuals with other neurological disorders, were used to recognize the antigenic peptides by western blot (WB). In the active NCC the 28-32 and 39-42 kDa peptides were more frequently detected in CSF than in sera (p < 0.05). The 47-52, 64-68, and 70 kDa antigens showed high frequencies in both samples from patients with active NCC. All the CSF samples of inactive NCC and other neurological disorder (control) patients tested negative, while serum samples from these last two groups recognized mainly the 80, 86, 95, and 98 kDa bands. This finding eliminates the use of the high molecular weigh bands (> 80 kDa) for diagnosis of NCC. The final conclusions were that the difference between active and inactive NCC may be done with the detection of peptides only in the CSF samples and that the 47-52, 64-68, and 70 kDa bands may be included as specific markers for active NCC when detected in CSF samples by WB using total saline extract of T. solium metacestode.
Resumo:
Schistosomes are endoparasites causing a serious human disease called schistosomiasis. The quantification of parasite genetic diversity is an essential component to understand the schistosomiasis epidemiology and disease transmission patterns. In this paper, we propose a novel assay for a rapid, low costly and efficient DNA extraction method of egg, larval and adult stages of Schistosoma mansoni. One euro makes possible to perform 60,000 DNA extraction reactions at top speed (only 15 min of incubation and 5 handling steps).
Resumo:
A study of crepuscular and night-biting mosquitoes was conducted at remote settlements along the Padauiri River, middle Negro River, state of Amazonas, Brazil. Collections were performed with human bait and a CDC-light trap on three consecutive days per month from June 2003-May 2004. In total, 1,203 h of collection were performed, of which 384 were outside and 819 were inside houses. At total of 11,612 specimens were captured, and Anophelinae (6.01%) were much less frequent than Culicinae (93.94%). Anopheles darlingi was the most frequent Anophelinae collected. Among the culicines, 2,666 Culex (Ae.) clastrieri Casal & Garcia, 2,394 Culex. (Mel.) vomerifer Komp, and 1,252 Culex (Mel.) eastor Dyar were the most frequent species collected. The diversity of insects found reveals the receptivity of the area towards a variety of diseases facilitated by the presence of vectors involved in the transmission of Plasmodium, arboviruses and other infectious agents.
Resumo:
The aim of this study was to compare two nucleic acid extraction methods for the recovery of enteric viruses from activated sludge. Test samples were inoculated with human adenovirus (AdV), hepatitis A virus (HAV), poliovirus (PV) and rotavirus (RV) and were then processed by an adsorption-elution-precipitation method. Two extraction methods were used: an organic solvent-based method and a silica method. The organic-based method was able to recoup 20% of the AdV, 90% of the RV and 100% of both the PV and HAV from seeded samples. The silica method was able to recoup 1.8% of the AdV and 90% of the RV. These results indicate that the organic-based method is more suitable for detecting viruses in sewage sludge.
Resumo:
This study is aimed at evaluating the potential to detect human immunodeficiency virus (HIV) in amniotic fluid (AF) collected at delivery from 40 HIV-positive pregnant women. Thirty patients had a plasma viral load (VL) below 1,000 copies/mL at delivery. VL was positive in three AF samples. No significant association was found between the HIV-1 RNA in AF and the maternal plasma samples. There was no HIV vertical transmission detected.
Resumo:
To evaluate commercial Lionex TB together with four antigens of Mycobacterium tuberculosis (MPT-64, MT10.3, 16 kDa and 38 kDa) for IgG and IgA cerebrospinal fluid (CSF) detection in the diagnosis of tuberculosis meningitis (TBM) with CSF negative acid-fast bacilli staining, 19 cases of TBM, 64 cases of other infectious meningoencephalitis and 73 cases of other neurological disorders were tested by enzyme linked immunosorbent assay. IgA-MPT-64 and IgG Lionex showed the highest sensitivities, specificities, positive predictive value and negative predictive value (63.2%, 47.4%; 95%, 93.7%; 40%, 98% and 28.4%, 97.1%, respectively). However, while grey zone was 12.7% and 6%, respectively, lowering sensitivity but maintains high specificity (> 95%). High protein concentration in CSF was associated with antibody positivity CSF/HIV+ which did not influence the sensitivity of both tests. To our knowledge, this is the first description of IgA-MPT-64 and IgG Lionex antibodies in CSF-TBM and, although there is good specificity, adjustments are needed based on antigen composition to enhance sensitivity.
Resumo:
Objective: To identify the prevalence of nursing diagnosis of fluid volume excess and their defining characteristics in hemodialysis patients and the association between them. Method: Cross-sectional study conducted in two steps. We interviewed 100 patients between the months of December 2012 and April 2013 in a teaching hospital and one hemodialysis clinic. The inference was performed by diagnostician nurses between July and September 2013. Results: The diagnostic studied was identified in 82% of patients. The characteristics that were statistically associated: bounding pulses, pulmonary congestion, jugular vein distention, edema, change in electrolytes, weight gain, intake greater than output and abnormal breath sounds. Among these, edema and weight gain had the highest chances for the development of this diagnostic. Conclusion: The analyzed diagnostic is prevalent in this population and eight characteristics presented significant association.