73 resultados para Software Acquisition


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT The successful in the implementation of wind turbines depends on several factors, including: the wind resource at the installation site, the equipment used, project acquisition and operational costs. In this paper, the production of electricity from two small wind turbines was compared through simulation using the computer software HOMER - a national model of 6kW and an imported one of 5kW. The wind resources in three different cities were considered: Campinas (SP/BR), Cubatão (São Paulo/BR) and Roscoe (Texas/ USA). A wind power system connected to the grid and a wind isolated system - batteries were evaluated. The results showed that the energy cost ($/kWh) is strongly dependent on the windmill characteristics and local wind resource. Regarding the isolated wind system – batteries, the full supply guarantee to the simulated electrical load is only achieved with a battery bank with many units and high number of wind turbines, due to the intermittency of wind power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the development of a two-dimensional interactive software environment for structural analysis and optimization based on object-oriented programming using the C++ language. The main feature of the software is the effective integration of several computational tools into graphical user interfaces implemented in the Windows-98 and Windows-NT operating systems. The interfaces simplify data specification in the simulation and optimization of two-dimensional linear elastic problems. NURBS have been used in the software modules to represent geometric and graphical data. Extensions to the analysis of three-dimensional problems have been implemented and are also discussed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em diversos estudos interdisciplinares em que a Anatomia Vegetal é utilizada, análises quantitativas complementares são necessárias. Geralmente, a avaliação micromorfométrica é feita manualmente e/ou utilizando programas computacionais de análise de imagens não específicos. Este trabalho teve como objetivo desenvolver um programa específico para Anatomia Vegetal quantitativa e testar sua eficiência e aceitação por usuários. A solução foi elaborada na linguagem Java, visando maior mobilidade em relação ao sistema operacional a ser usado. O software desenvolvido foi denominado ANATI QUANTI e testado pelos alunos, pesquisadores e professores do Laboratório de Anatomia Vegetal da Universidade Federal de Viçosa (UFV). Todos os entrevistados receberam fotos para efetuarem medições no ANATI QUANTI e comparar com os resultados obtidos utilizando o software disponível. Os voluntários, através de questionários previamente formulados, destacaram as principais vantagens e desvantagens do programa desenvolvido em relação ao software disponível. Além de ser mais específico, simples e ágil do que o software disponível, o ANATI QUANTI é confiável, atendendo à expectativa dos entrevistados. Entretanto, há necessidade de acrescentar recursos adicionais, como a inserção de novas escalas, o que aumentaria a gama de usuários. O ANATI QUANTI já está em uso nas pesquisas desenvolvidas por usuários na UFV. Por ser um software livre e de código aberto, será disponibilizado na internet gratuitamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses, from the standpoint of cellular biology, the deterministic and indeterministic androgenesis theories. The role of the vacuole and of various types of stresses on deviation of the microspore from normal development and the point where androgenetic competence is acquired are examined. Based on extensive literature review and data on wheat studies from our laboratory, a model for androgenetic capacity of pollen grain is proposed. A two point deterministic model for in vitro androgenesis is our proposal for acquisition of androgenetic potential of the pollen grain: the first switch point would be early meiosis and the second switch point the uninucleate pollen stage, because the elimination of cytoplasmatic sporophytic determinants takes place at those two strategic moments. Any abnormality in this process allowing the maintenance of sporophytic informational molecules results in the absence of establishment of a gametophytic program, allowing the reactivation of the embryogenic process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze retinol equivalent and iron content in different food composition tables and nutritional evaluation software programs. A literature search was conduct to identify tables and software available in Brazil containing information about retinol equivalent and iron content that are currently used by nutritionists. Ten tables and five software programs were selected for this study. The methodology used to present the retinol equivalent and iron content was evaluated and no pattern to obtain such content was found in the tables and software programs analyzed. Only one of the tables had enough information for the calculation of retinol equivalents; this table is recommended to all Latin America As for the iron content, three of the tables analyzed stand out and therefore should be used; two of them are based on national foods and the other is recommended for use in all Latin America countries. None of the software programs evaluated use the conversion factors suggested by IVACG to assess the vitamin A content in foods. Special attention should be given to the content of iron provided in the software programs since they use tables as international sources and fortified foods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study's objective was to analyze the procedures aimed at guaranteeing sanitary conditions when acquiring meat. The study was conducted with university restaurants of the Federal Institutions of Higher Education (IFES) located in the five regions of Brazil. Data were collected using a questionnaire and an evaluation list, which was available online to restaurant professionals. The results showed that restaurants chose one or two types of meat, the most frequent of which were beef and chicken. In restaurants managed by the IFES, the acquisition of raw material occurred by bidding. For vendor selection, the restaurants required product registration with the Inspection Service and requested regulation of the supplier by the Health Surveillance. Monitoring was carried out through a technical visit to the supplier and a review of the past records of the supplier. A higher percentage of restaurants in the Southeast region met appropriate sanitary and hygienic criteria for the receipt of meat, followed by the South, Midwest, Northeast and North. We conclude that restaurants meet most of the safety criteria set in the legislation. However, some weaknesses are evident in the physical and functional structure, the system of transportation of raw material and the records of control measures at the place of reception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A primary interest of image analysis of X-rayed seeds is to identify whether the extent of fill in the embryo cavity is associated with to seed physiological quality. The objective of this research was to verify the accuracy of the freely available Tomato Analyzer (TA) software developed at The Ohio State University to determine the ratio of embryo size over total seed area. Seeds of pumpkin, watermelon, cucumber and cotton were X-rayed and analyzed by the software which defines seed and embryo boundaries and automatically generates numerical values to quantify that ratio. Results showed that the TA has the sensitivity to evaluate the extent of embryo growth within the cucurbits and cotton seeds and is a promising alternative for this assessment in other seed species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.