163 resultados para Quantitative sensory test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le test ELISA-TÉTANOS (Biosys, France) a été utilisé pour le titrage des anti-corps tétaniques (sensibilité = 0,0025 UI/ml) en sérums humains de donneurs de sang, 566 hommes et 108 femmes, âges de 18 à 58 ans, moyenne de 29 ans, provenant de São Paulo, SP, Brésil. L'OMS, acceptant seulement la séroneutralisation sur souris (NT), la méthode de référence, pour les études sur la protection contre le tétanos, préconise le titre de 0,01 UI/ml comme minimum protecteur. BOURLEAUD & HUET ont proposé la limite de 0,06 UI/ml quand s'emploie le test ELISA, en attendant à une certaine discordance inévitable entre les méthodes. Parmi les 674 sérums étudiés, 178 (26,41%) n'ont pas présenté d'anticorps (< 0,0025 UI/ml); 413 (61,28%) ont présenté des résultats égaux ou supérieurs à 0,01 UI/ml et en 232 (34,42%) les titres ont été égaux ou supérieurs à 0,06 UI/ml. Le pourcentage d'individus protégés a été inversement proportionnel à 1'âge: environ 50% dans le groupe le plus jeune (hommes de 18 à 35 ans et femmes de 18 à 23 ans) contre environ 10% dans le groupe de plus de 42 ans ont présenté des titres sûrement protecteurs (> 0,06 UI/ml).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylori was investigated in 189 patients for culture, microscopic visualization of campylobacter-like organisms (CLO) and a ten minute urease test. In 136 (72%) the bacteria was isolated, and in 98 of them CLO were histologically detected. Specificity, sensitivity, positive and negative predictive values of microscopic visualization of CLO were: 0.77, 0.73, 0.97 and 0.51, respectively; 98 culture-positive patients were urease test positive. Specificity, sensitivity, positive and negative predictive values of the urease test were: 0.83, 0.72, 0.92 and 0.54, respectively. Comparing the urease test with culture of H. pylori combined with microscopic visualization of CLO, its specificity, sensitivity, positive and negative predictive values were: 0.95, 0.71, 0.98 and 0.48, respectively. Probably, these values are not real, since bacteria different from H. pylori could be misclassified as CLO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se evaluó la utilidad de la prueba de aglutinación directa (AD) para diagnosticar el Mal de Caderas. Se emplearon cuarenta y cuatro sueros provenientes de dos lotes de equinos naturalmente infectados con el Trypanosoma evansi (Lote 1 y Lote 2). La AD fue positiva (Aglutinación > 1:512) en 13 de 16 equinos (81.2%), de los que se aislaron los parásitos. En doce de estos animales (92%) se detectaron IgM anti T. evansi mediante la AD realizada con 2-mercaptoetanol (AD + 2-ME). La AD fue positiva en 17 de los 28 equinos que resultaron negativos al diagnóstico parasitológico. Un tercer lote de cinco equinos infectados con T. evansi que presentaba elevados títulos de AD, fue tratado con Suramina Sódica (Nagano1-Bayer). La AD + 2-ME evidenció en cuatro animales que, gran parte de estos anticuerpos se ubicaban en la fracción IgM. Posterior al tratamiento farmacológico y, en concordancia de la negativización de la parasitemia, la detección de la IgM anti T. evansi no fue posible, mientras que los anticuerpos IgG continuaron detectándose a los doce meses post-tratamiento en valores de 1:512, en tres animales. Cincuenta sueros de equinos de una zona libre del parásito, que se emplearon como controles, fueron negativos a la AD. Se recomienda la utilización de la AD y AD + 2-ME para el uso de rutina en el diagnóstico del Mal de Caderas de los equinos, en combinación con otros métodos parasitológicos sensibles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diversas alterações na concentração sérica dos hormônios tiroidianos têm sido descritas em associação a doenças crônicas não-tiroidianas. Com relação às doenças hepáticas crônicas, a síndrome do T3 baixo foi descrita em pacientes cirróticos, enquanto a síndrome do T4 elevado foi encontrada em esquistossomóticos com a forma hepatoesplênica compensada. Com o intuito de verificar se as alterações relatadas na esquistossomose mansônica eram de origem "periférica" ou "central", realizamos a prova do TRH-TSH em 12 pacientes esquistossomóticos "puros" (6 hepatointestinais e 6 hepatoesplênicos compensados) e em 5 indivíduos controle. Os resultados obtidos demonstram que o eixo hipotálamo-hipofisário é normal nas formas crônicas da esquistossomose e que provavelmente as alterações previamente relatadas devem ser '"periféricas" e não " centrais".