158 resultados para Pressure suits.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information on the spatial structure of soil physical and structural properties is needed to evaluate the soil quality. The purpose of this study was to investigate the spatial behavior of preconsolidation pressure and soil moisture in six transects, three selected along and three across coffee rows, at three different sites under different tillage management systems. The study was carried out on a farm, in Patrocinio, state of Minas Gerais, in the Southeast of Brazil (18 º 59 ' 15 '' S; 46 º 56 ' 47 '' W; 934 m asl). The soil type is a typic dystrophic Red Latosol (Acrustox) and consists of 780 g kg-1 clay; 110 g kg-1 silt and 110 g kg-1 sand, with an average slope of 3 %. Undisturbed soil cores were sampled at a depth of 0.10-0.13 m, at three different points within the coffee plantation: (a) from under the wheel track, where equipment used in farm operations passes; (b) in - between tracks and (c) under the coffee canopy. Six linear transects were established in the experimental area: three transects along and three across the coffee rows. This way, 161 samples were collected in the transect across the coffee rows, from the three locations, while 117 samples were collected in the direction along the row. The shortest sampling distance in the transect across the row was 4 m, and 0.5 m for the transect along the row. No clear patterns of the preconsolidation pressure values were observed in the 200 m transect. The results of the semivariograms for both variables indicated a high nugget value and short range for the studied parameters of all transects. A cyclic pattern of the parameters was observed for the across-rows transect. An inverse relationship between preconsolidation pressure and soil moisture was clearly observed in the samples from under the track, in both directions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this communication we describe the application of a conductive polymer gas sensor as an air pressure sensor. The device consists of a thin doped poly(4'-hexyloxy-2,5-biphenylene ethylene) (PHBPE) film deposited on an interdigitated metallic electrode. The sensor is cheap, easy to fabricate, lasts for several months, and is suitable for measuring air pressures in the range between 100 and 700 mmHg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoemulsions composed of a medium-chain triglyceride oil core stabilized by rapeseed or sunflower lecithins were prepared by spontaneous emulsification and high-pressure homogenization. These nanoemulsions are compared with formulations stabilized by egg lecithin. Nanoemulsions obtained by high-pressure homogenization display larger droplet size (230 to 440 nm) compared with those obtained by spontaneous emulsification (190 to 310 nm). The zeta potentials of the emulsions were negative and below -25 mV. Zeta potential inversion occurred between pH 3.0 and 4.0. The results demonstrate the feasibility of preparing lipid emulsions comprising rapeseed or sunflower lecithins by spontaneous emulsification and high-pressure homogenization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When using appropriate inflation pressures and load capacity (ballast), it may obtain a higher yield and prolongation of the life of the tire, besides it may minimize the problems of loss of traction, increased slippage and fuel consumption. This study aimed to evaluate the fuel consumption of a tractor operating with new and worn tires in three conditions of ballasting and three inflation pressures, when driving on compacted soil with vegetation cover. The experiment was conducted at the experimental unit from the Department of Animal Science, Federal University of Lavras, state of Minas Gerais, Brazil, in an agricultural soil compacted by cattle trampling and with vegetation cover. It was used a tractor 4x2 with front wheel assist, of a 65.62 kW engine power. The tires were of R1 type, diagonal (front: 12.4 to 24; and rear: 18.4 to 30), the average height of the clutches of the new tires were 0.3 and 0.35 m for front and rear tires, respectively, and for the worn tires were 0.018 and 0.0045 m, for the front and the rear tires, respectively. The results showed advantages for the tractor equipped with new tires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tire inflation pressure, among other factors, determines the efficiency in which a tractor can exert traction. It was studied the effect of using two tire inflation pressures, 110.4 kPa in the front and rear wheels, 124.2 kPa in the front wheel and 138 kPa in the rear wheels, the energetic efficiency of an agricultural tractor of 147 kW of engine power, in the displacement speed of 6.0 km.h-1, on track with firm surface, with the tractor engine speed of 2000 rpm. For each condition of the tire pressure, the tested tractor was subjected to constant forces in the drawbar of 45 kN and 50 kN, covering 30 meters. It was used a randomized complete block with a 2x2 factorial arrangement (tire pressure and drawbar power) with four replications, totaling 16 experimental units. Data were subjected to analysis of variance, using the Tukey test at 5% probability for comparison averages. The lowest hourly and specific fuel consumption, the lowest slippage of the wheelsets and the highest efficiency in the drawbar was obtained with the tire inflation pressure of 110.4 kPa in the front and rear tires of the tractor, highlighting that lower pressures improve energetic and operational performance of the tractor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Each year, there is an increase in pesticide consumption and in its importance of use in the large-scale agricultural production, being fundamental the knowledge of application technology to the activity success. The objective of the present study was to evaluate the influence of working pressure on the drift generated by different spray nozzles, assessed in wind tunnel. The treatments were composed of two spray nozzles AXI 110015 and AXI 11002 with pressure levels of 276 and 414 kPa. The spray solution was composed by water and NaCl at 10%. The applications were conducted at wind speed of 2.0 m s-1, being the drift collected at 5.0; 10.0 and 15.0 m away from the spray boom and at heights of 0.2; 0.4; 0.6; 0.8 e 1.0 m from the tunnel floor. To both spray nozzles, the greatest drift was collected at the smallest distance to the spray-boom and at the lowest height. The AXI 11002 nozzle gave a smaller drift relative to the AXI 110015 nozzle for the two tested pressures and for all the collection points. Regardless of the nozzle, a rise in the working pressure increases the spray drift percentage at all distances in the wind tunnel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Microsprinkler non-pressure compensating nozzles usually show water flow variation along the lateral line. This study aimed at adapting microtubes into non-compensating system of microsprinklers previous installed in the field, as a self-compensated nozzle, to improve the flow uniformity along the lateral line. Microtubes were adapted to three types of commercial microsprinklers. Tests were conducted, both in the laboratory and in field, to evaluate the microsprinkler performance at four different flows (40, 50, 60 and 70 L h-1) under pressure head range from 75 to 245 kPa. Nozzles presented coefficient of flow-rate variation (CVq) lower than 5.5% and distribution uniformity (DU) greater than 95%, which are classified as excellent. The original spatial water distribution of the microsprinkler did not change by using microtube as a nozzle. This device adapted to non-pressure compensating microsprinklers are functional and operate effectively with flows ranging up to 70 L h-1. Small variations at microsprinkler flows along the lateral line can occur, however, at random manner, which is common for pressure-compensating nozzles. Therefore, the microtube technique is able to control pressure variation in microsprinklers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT For drip irrigation design and management, it is necessary to know the relation between flow and pressure acting on emitters. In the case of subsurface drip irrigation, the backpressure phenomenon may change the hydraulic characteristics of emitters. Thus, this study aimed at determining such relationship between flow and pressure of different driplines in surface and subsurface conditions; aiming to find possible differences in hydraulic behavior. We tested four emitter types; two pressure compensating (D5000 and Hydro PCND) and two non-pressure compensating (TalDrip and Jardiline). Emitter flow rates were attained in atmospheric conditions and submerged in water, in which submergence levels represented backpressure. Assays were performed using inlet pressures of 80, 100, 120, and 150 kPa for the Hydro PCND dripline and 25, 50, 100, and 150 kPa for the other ones; the backpressures were of 0.49, 1.47, 2.45, 4.41 and 6.37 kPa with four replications. The emitters had their proportionality constants and discharge exponents changed in submerged applications, representing backpressure effect. Non-pressure compensating emitters had their discharge exponent decreased, while in pressure compensating ones, it was increased. Backpressure reduced emitter flow rates at all evaluated pressures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the combined treatment of ear lobe keloids. METHODS: We studied 46 consecutive patients with 81 ear lobe keloids. Patients underwent local infiltration of triamcinolone acetonide (TCN) at concentrations of 40mg/ml (Group 1), 20 mg/ml (Group 2) and 10mg/ml (Group 3). The volume of TCN infiltrate varied according to the size of the lesion. Treatment consisted of three monthly injections before surgery, excision of keloid in the fourth month and perioperative infiltration, followed by two more leaks TCN within two months. Patients used earrings pressure on the scar after operation for four months. The pressure exerted by earrings in the ear lobe was measured electronically. Post-treatment follow-up of patients was 24 months. RESULTS: TCN at concentrations of 20mg/ml and 40mg/ml were effective for the treatment of keloids, no difference between the groups (p = 0.58). However, patients in which TCN was infiltrated the 10mg/ml had poor involution of keloid and the study of this group was stopped. CONCLUSION: the combination of infiltration TCN month to 20 mg/mL (1.2mg to 2.0mg per mm3 TCN injury), surgical excision and pressure application device is effective for treatment of keloid ear lobe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to establish reference values for selected ophthalmic diagnostic tests in New Zealand rabbits (Oryctolagus cuniculus). A total of 22 adult male rabbits were used. The ophthalmic tests included evaluation of tear production with Schirmer tear test 1(STT1) and Endodontic absorbent paper point tear test (EAPPTT) using two different commercial brand materials. Applanation tonometry, Culture of the conjunctival bacterial flora, , conjunctival cytology and conjunctival histology were also performed. Mean (±SD) for STT1, EAPPTTa, EAPPTTb and IOP was 7.27±2.51mm/min, 12.43±1.69mm/min, 15.24±2.07mm/min, 12.89±2.80mm Hg, respectively. Staphylococcus epidermidis, Staphylococcus sp. and Bacillus sp. were predominant. The cytological evaluation revealed the presence columnar epithelial cells, superficial squamous keratinized cells, lymphocytes, heterophils, red blood cells, mucus and bacteria. The histological analysis revealed a stratified epithelium, characterized by the presence of columnar epithelial cells with a large number of goblet cells. The reported data can be used for therapeutic or experimental purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.