333 resultados para Immunofluorescence test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental model of paracoccidioidomycosis induced in mice by the intravenous injection of yeast-forms of P. brasiliensis (Bt2 strain; 1 x 10(6) viable fungi/animal) was used to evaluate sequentially 2, 4, 8, 16 and 20 weeks after inoculation: 1. The presence of immunoglobulins and C3 in the pulmonary granuloma-ta, by direct immunofluorescence; 2. The humoral (immunodiffusion test) and the cellular (footpad sweeling test) immune response; 3. The histopathology of lesions. The cell-immune response was positive since week 2, showing a transitory depression at week 16. Specific antibodies were first detected at week 4 and peaked at week 16. At histology, epithelioid granulomas with numerous fungi and polymorphonuclear agreggates were seen. The lungs showed progressive involvement up to week 16, with little decrease at week 20. From week 2 on, there were deposits of IgG and C3 around fungal walls within the granulomas and IgG stained cells among the mononuclear cell peripheral halo. Interstitital immunoglobulins and C3 deposits in the granulomas were not letected. IgG and C3 seen to play an early an important role in. the host defenses against P. brasiliensis by possibly cooperating in the killing of parasites and blocking the antigenic diffusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le test ELISA-TÉTANOS (Biosys, France) a été utilisé pour le titrage des anti-corps tétaniques (sensibilité = 0,0025 UI/ml) en sérums humains de donneurs de sang, 566 hommes et 108 femmes, âges de 18 à 58 ans, moyenne de 29 ans, provenant de São Paulo, SP, Brésil. L'OMS, acceptant seulement la séroneutralisation sur souris (NT), la méthode de référence, pour les études sur la protection contre le tétanos, préconise le titre de 0,01 UI/ml comme minimum protecteur. BOURLEAUD & HUET ont proposé la limite de 0,06 UI/ml quand s'emploie le test ELISA, en attendant à une certaine discordance inévitable entre les méthodes. Parmi les 674 sérums étudiés, 178 (26,41%) n'ont pas présenté d'anticorps (< 0,0025 UI/ml); 413 (61,28%) ont présenté des résultats égaux ou supérieurs à 0,01 UI/ml et en 232 (34,42%) les titres ont été égaux ou supérieurs à 0,06 UI/ml. Le pourcentage d'individus protégés a été inversement proportionnel à 1'âge: environ 50% dans le groupe le plus jeune (hommes de 18 à 35 ans et femmes de 18 à 23 ans) contre environ 10% dans le groupe de plus de 42 ans ont présenté des titres sûrement protecteurs (> 0,06 UI/ml).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylori was investigated in 189 patients for culture, microscopic visualization of campylobacter-like organisms (CLO) and a ten minute urease test. In 136 (72%) the bacteria was isolated, and in 98 of them CLO were histologically detected. Specificity, sensitivity, positive and negative predictive values of microscopic visualization of CLO were: 0.77, 0.73, 0.97 and 0.51, respectively; 98 culture-positive patients were urease test positive. Specificity, sensitivity, positive and negative predictive values of the urease test were: 0.83, 0.72, 0.92 and 0.54, respectively. Comparing the urease test with culture of H. pylori combined with microscopic visualization of CLO, its specificity, sensitivity, positive and negative predictive values were: 0.95, 0.71, 0.98 and 0.48, respectively. Probably, these values are not real, since bacteria different from H. pylori could be misclassified as CLO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey of the prevalence of Trypanosoma cruzi infection was carried out in Oitis, a small community in the State of Piaui, Brazil. Two hundred and sixty five individuals were screened by microscopic examination, hémoculture, indirect immunofluorescence (IFA), enzyme-linked immunosorbent assay (ELISA), and competitive enzyme-linked immunosorbent assay (C-ELISA) using the monoclonal antibody TCF87 against to a 25kd T. cruzi antigen. Seropositivity was 14.3% by the IFA test, 14.7% by ELISA, and 13.2% by C-ELISA. The C-ELISA using the TCF87 monoclonal antibody seems to be applicable in serodiagnosis of Chagas' disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The obtainment of monoclonal antibodies for adenovirus species 4(Ad4) is described.The specificities of selected monoclonal antibodies were determined by means of viral neutralization test in cell culture, immunofluorescence and Enzyme-Linked Immunosorbent Assay (ELISA), in the presence of the following species of human adenovirus: 1, 2, 5 (subgenus C), 4 (subgenus E), 7 and 16 (subgenus B) and 9 (subgenus D). Two monoclonal antibodies species specific to adenovirus 4 (1CIII and 3DIII) and one monoclonal antibody that cross reacted with adenovirus species 4 and 7 (2HIII) were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se evaluó la utilidad de la prueba de aglutinación directa (AD) para diagnosticar el Mal de Caderas. Se emplearon cuarenta y cuatro sueros provenientes de dos lotes de equinos naturalmente infectados con el Trypanosoma evansi (Lote 1 y Lote 2). La AD fue positiva (Aglutinación > 1:512) en 13 de 16 equinos (81.2%), de los que se aislaron los parásitos. En doce de estos animales (92%) se detectaron IgM anti T. evansi mediante la AD realizada con 2-mercaptoetanol (AD + 2-ME). La AD fue positiva en 17 de los 28 equinos que resultaron negativos al diagnóstico parasitológico. Un tercer lote de cinco equinos infectados con T. evansi que presentaba elevados títulos de AD, fue tratado con Suramina Sódica (Nagano1-Bayer). La AD + 2-ME evidenció en cuatro animales que, gran parte de estos anticuerpos se ubicaban en la fracción IgM. Posterior al tratamiento farmacológico y, en concordancia de la negativización de la parasitemia, la detección de la IgM anti T. evansi no fue posible, mientras que los anticuerpos IgG continuaron detectándose a los doce meses post-tratamiento en valores de 1:512, en tres animales. Cincuenta sueros de equinos de una zona libre del parásito, que se emplearon como controles, fueron negativos a la AD. Se recomienda la utilización de la AD y AD + 2-ME para el uso de rutina en el diagnóstico del Mal de Caderas de los equinos, en combinación con otros métodos parasitológicos sensibles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new serological test, the gelatin particle agglutination test (GPAT), was used for the serodiagnosis of schistosomiasis mansoni. This technique showed the sensitivity (90.6%) and specificity (97.8%) close to those of enzyme-linked immunosorbent assay. The GPAT can be easily and rapidly performed without specialized equipment, by using lyophilized antigen-coated gelatin particles. The test also seems to be useful for mass screening of Schistosoma infection in field conditions.