399 resultados para Esotropia - correção
Resumo:
One of the main problems in quantitative analysis of complex samples by x-ray fluorescence is related to interelemental (or matrix) effects. These effects appear as a result of interactions among sample elements, affecting the x-ray emission intensity in a non-linear manner. Basically, two main effects occur; intensity absorption and enhancement. The combination of these effects can lead to serious problems. Many studies have been carried out proposing mathematical methods to correct for these effects. Basic concepts and the main correction methods are discussed here.
Resumo:
Raman imaging spectroscopy is a highly useful analytical tool that provides spatial and spectral information on a sample. However, CCD detectors used in dispersive instruments present the drawback of being sensitive to cosmic rays, giving rise to spikes in Raman spectra. Spikes influence variance structures and must be removed prior to the use of multivariate techniques. A new algorithm for correction of spikes in Raman imaging was developed using an approach based on comparison of nearest neighbor pixels. The algorithm showed characteristics including simplicity, rapidity, selectivity and high quality in spike removal from hyperspectral images.
Resumo:
Este artigo apresenta um procedimento para estudo do comportamento mecnico de trs solos oriundos da empresa CENIBRA S. A., localizada na cidade de Belo Oriente, Minas Gerais, Brasil, para fins de emprego em revestimento primrio, reforo de subleito e sub-base de estradas florestais, classificados como argila amarela, argila vermelha e areia. Empregou-se, nesta investigao, a tcnica de estabilizao mecnica de solos com correção granulomtrica. O programa de ensaios de laboratrio englobou o uso de vrias composies percentuais de solos, com base na mistura entre dois deles, de modo a obter um produto final eficiente para aplicaes nas estradas florestais da CENIBRA S. A. Trabalhou-se com os percentuais de 60, 70 e 80% de areia e de 20, 30 e 40% das argilas nas composies das misturas, compactando estas na energia do ensaio Proctor Modificado. A melhor resposta mecnica foi obtida pela mistura de 80% de areia e 20% de argila amarela, com capacidade de carga representada pelo ISC de 63%.
Resumo:
Este trabalho apresenta o desenvolvimento de um equipamento microprocessado, de baixo custo, para gerao de sinal de correção diferencial para GPS, em tempo real, e configurao e superviso do receptor GPS base. O equipamento desenvolvido possui um microcontrolador dedicado, display alfanumrico, teclado multifuno para configurao e operao do sistema e interfaces de comunicao. O circuito eletrnico do equipamento tem a funo de receber as informaes do GPS base e interpret-las, transformando-as numa sentena no protocolo RTCM SC-104. O software do microcontrolador responsvel pela converso do sinal recebido pelo GPS base, do formato proprietrio para o protocolo RTCM SC-104. A placa processadora principal possui duas interfaces seriais padro RS-232C. Uma delas tem a funo de configurao e leitura das informaes geradas pelo receptor GPS base. A outra atua somente como sada, enviando o sinal de correção diferencial. O projeto do equipamento microprocessado mostrou que possvel a construo de uma estao privada para a gerao do sinal de correção diferencial, de baixo custo.
Resumo:
Traunatic perineal hernia remains a rare clinical entity despite an overall increase in blunt trauma. Because of the incidence of other associated injuries, the mortality is high. Most of the perineal defects are repaired during the orthopaedics surgery to reconstitute the pelvis and few patients develop a true perineal hernia without pelvic instability. A 80-year-old woman was involved in a running over accident with disjunction of pubic symphysis, dislocation of sacrum-iliac junction and fracture of pubis and ischium. The patient was submitted to an orthopaedic surgery and latter development an perineal hernia through the genitalia. The diagnosis could be established with physical examination alone. Conventional radiology, computadorized tomography, and ultrasound should also be done to progran the surgery. The repair approach was performed using a marlex mesh, fixed in the pelvic bones, Cooper ligament, and the abdominal wall. The mesh was stood in a retro- peritoneal position, rebuilding the pelvic floor without reconstruction the pelvic bones. We conclude that this is an efficient approach to repair of traumatic postoperative perineal hernia, mainly in patients with high operative risk, when the osseous repair is not necessary.
Resumo:
Diaphragmatic hernia secondary to blunt or penetrating trauma is rarely by itself a fatal event. However, if unpercieved, it may lead to severe complications caused by herniation of abdominal contents to the ethorax. Blunt trauma related to car accidents is the most frequent cause of diaphragmatic hernias. Associated injuries are frequently observed, provoked by severe traumas of great impact. These blunt trauma hernias occur mainly on the left side due to abdominal anatomy, since the liver is usually located on the right side. When injuries are observed on the right they tend to be more severe, generally related to major trauma of solid organs. Less frequently diaphragmatic hernias may be bilateral. The management of diaphragmatic injury would appear to be a simple matter of suturing the defect. However, peroperative diagnosis can be difficult and even at the time of surgery some diaphragmatic injuries can be overlooked if carefull exploration is not done. Associated injuries tend to divert attention from the diaphragmatic injury. Laparoscopic diagnosis and repair have been described with successfull. Laparotomy or thoracotomy can be employed for surgical repair of traumatic diaphragmatic hernias. Standard (laboratory/imaging) examinations may fail to make the diagnosis. Recently, the laparoscopic approach has proved useful for more precise evaluation of such injuries, very often allowing immediate repair of these lesions.
Resumo:
Videolaparoscopy has been widely used in the treatment of pathologies as cholelithiasis, appendicitis and adrenal tumor. Nowadays, has also been used to treat type II endoleaks after endovascular repair of abdominal aortic aneurysms. The goal of this work is to report one case of inferior mesenteric artery endoleak treated by videolaparoscopy.
Resumo:
Abdominal aortic aneurysm reconstruction is usually performed in vascular surgical practice. However, the repair of an abdominal aortic aneurysm associated with a pelvic kidney is rare. Our goal is to present a case report of an abdominal aortic aneurysm associated with two congenital pelvic kidneys wich was treated successfully by aneurysmectomy and inclusion of an aortoaortic graft.
Resumo:
OBJETIVO: Verificar a possibilidade de implantao e a capacidade de resistncia tnsil do peritnio parietal bovino como tela cirrgica na correção de hrnia ventral em um modelo animal de experimentao. MTODO: Utilizando 57 ratos machos Wistar, comparou-se o implante do peritnio bovino com a tela de polipropileno na correção de um defeito provocado na parede abdominal do animal. Aps sete (sub-grupo A) e 28 (sub-grupo B) dias de observao, as peas foram retiradas e procedeu-se a avaliao da resistncia trao em Mquina Universal de Ensaios. Um grupo sem implante de material prottico foi utilizado como controle nos testes de fora tnsil. Os testes de Mann-Whitney e de Kruskal-Wallis foram utilizados e estabeleceu-se em 0,05 o nvel para rejeio da hiptese de nulidade. RESULTADOS: Os testes de resistncia trao, com valores expressos em Newton, no mostraram diferenas estatsticas entre os grupos estudados, tanto no 7 quanto no 28 dia de ps-operatrio, e ambos foram menos resistentes que a parede abdominal normal (p = 0,003). CONCLUSO: O peritnio parietal bovino apresentou resistncia tnsil semelhante a da tela de polipropileno em um modelo de correção de hrnia ventral em ratos.
Resumo:
The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .
Resumo:
OBJETIVO: Comparar os resultados anatmicos ps-operatrios de pacientes portadoras de prolapso uterino tratadas utilizando tela de polipropileno para correção dos defeitos do assoalho plvico, comparando histerectomia vaginal com a preservao do tero. MTODO: Estudo randomizado com 31 mulheres portadoras de prolapso uterino estdio III ou IV (POP-Q) divididas em dois grupos: Grupo HV- 15 mulheres submetidas histerectomia vaginal e reconstruo da anatomia do assoalho plvico com tela de polipropileno tipo I (Nazca R-Promedon) e Grupo HP- 16 mulheres mulheres submetidas reconstruo da anatomia do assoalho plvico com tela de polipropileno tipo I (Nazca R-Promedon) preservando o tero. Raa, urgncia miccional, constipao intestinal, dor sacral, sangramento e tempo de operao foram os parmetros analisados. RESULTADOS: O tempo de seguimento mdio foi de nove meses. No se observou diferena entre os grupos nas complicaes funcionais. O tempo cirrgico foi 120 minutos para grupo HV versus 58.9 minutos para grupo HP ( p < 0.001 ) e o volume de perda sangunea intraoperatria foi 120 mL no grupo HV versus 20 mL para grupo HP ( p < 0.001*). A taxa de sucesso objetivo foi 86.67% para grupo HV e 75% para grupo HP (p = 0,667). A taxa de eroso de tela foi 20% (3/15) de extruso no grupo HV versus 18,75% (3/16) no grupo HP (p = 1,000). CONCLUSO: A correção cirrgica do assoalho plvico com telas nas portadoras de prolapso uterino apresentaram similaridade quer sendo ela feita com histeropexia quer com histerectomia. Contudo, o tempo cirrgico e o volume da perda sangunea foram significantemente maiores no grupo com histerectromia (HV). Operaes vaginais com telas so procedimentos efetivos para a correção do prolapso.
Resumo:
OBJETIVO: Comparar o uso de tela de polipropileno e correção sitio-especfica no tratamento cirrgico do prolapso vaginal anterior. MTODOS: Estudo prospectivo randmico comparativo em que foram operadas 32 pacientes com idades entre 50 e 75 anos, que apresentavam prolapso vaginal anterior estdio III ou IV, ou recidivado. A esttica plvica foi avaliada segundo as recomendaes da International Continence Society (ICS), o sistema POP-Q e pelo ndice de Quantificao de Prolapso (POP-Q-I) Absoluto e Relativo. Para o rastreamento da incontinncia urinria de esforo oculta todas as pacientes, sintomticas ou no, foram submetidas a estudo urodinmico em posio semi-ginecolgica e semi-sentada, com reduo do prolapso com pina de Cheron. Registrou-se o tempo cirrgico, o volume de sangramento intra-operatrio e as complicaes intra e ps-operatrias. O tempo de seguimento mdio do estudo foi de 8,5 meses. RESULTADOS: Em relao aos resultados anatmicos ocorreu melhores resultados com a utilizao de tela de polipropileno sobre o reparo sitio-especfico. Em relao morbidade cirrgica, observou-se menor tempo cirrgico no grupo em que utilizou-se tela. CONCLUSO: Houve superioridade dos resultados anatmicos obtidos com a utilizao de tela de polipropileno sobre o reparo sitio-especfico.
Resumo:
OBJETIVOS: Anlise morfolgica e biomecnica do enxerto homlogo congelado de diafragma para correção de defeito da parede abdominal em ratos. MTODOS: Os animais foram distribuidos em controle (20 ratos Wistar) e experimento (30 ratos Wistar). Os do grupo controle foram submetidos laparotomia mediana e sutura da parede abdominal; j os do grupo experimento, resseco da parede abdominal e reconstruo com enxerto homlogo congelado de diafragma. Os animais foram submetidos eutansia no 3 e 6 ms de ps-operatrio e avaliados quanto presena de complicaes ps-operatrias, integridade do enxerto, presena de aderncias, avaliao tensiomtrica, avaliao histopatolgica com H/E e com sirius-red (colgeno tipo I e III). RESULTADOS: Houve integrao do enxerto em todos os animais sem complicaes. Aderncias foram semehantes entre os grupos controle e experimento aps trs e seis meses. Observaram-se maior fora mxima, fora de ruptura e tenso nos animais do grupo experimento aos trs meses de ps-operatrio (p=0,001; p=0,012 e p=0,001, respectivamente). Na correlao entre as diferentes variveis estudadas houve correlao estatisticamente significante entre fora mxima e tenso nos grupos controle e experimento (p=0,001 e p= 0,001), e nos subgrupos trs e seis meses (p=0,002 e p=0,001). Correlacionaram-se fora mxima e colgeno tipo I (p=0,04) e ndice de Maturao do Colgeno (IMaC) e fora mxima (p=0,03) ambos somente no grupo controle, mas nos subgrupos 3 e 6 meses (p=0,045 e p=0,038). O nmero de monomorfonucleares e fora mxima tambm apresentou significncia estatstica tanto para o grupo controle quanto para o experimento (p=0,005 e p=0,004, respectivamente). CONCLUSO: O enxerto homlogo congelado de diafragma mostrou ser boa alternativa no reparo de grandes defeitos da parede abdominal em ratos.
Resumo:
OBJETIVO: Verificar a eficcia e complicaes da correção cirrgica de hrnias incisionais por enxerto da tela de polipropileno envolta por tecido fibroso, em comparao com a tela de polipropileno. MTODOS: Foram utilizados 25 ratos Wistar machos e fmeas, distribudos em dois grupos: controle e experimento. O grupo experimento, com 15 animais, foi submetido ao implante da tela em seu tecido subcutneo. Aps 21 dias, a tela foi removida e serviu para correção de uma hrnia abdominal induzida. Os animais foram eutanasiados aps 21 dias e submetidos anlise macroscpica, tensional e microscpica. O grupo controle, foi submetido ao reparo da hrnia abdominal com a tela de polipropileno. RESULTADOS: Observou-se diferena significativa em relao anlise macroscpica de aderncias. O grupo controle obteve maior grau de aderncias em relao ao experimento (p= 0,003). No foi possvel afirmar que houve diferena significativa em relao anlise de fora tensional e microscopia. CONCLUSO: A tela de polipropileno envolta por tecido fibroso mostrou-se eficaz na correção das hrnias abdominais induzidas, com menor grau de aderncias macroscpicas quando comparada tela de polipropileno.
Resumo:
OBJETIVO: Avaliar a utilizao do fio de polipropileno de autossustentao de tripla convergncia para a correção do desvio de hemiface que se apresenta como sequela tardia da paralisia facial perifrica. MTODOS: Realizou-se um estudo retrospectivo e observacional em 34 indivduos portadores de paralisia facial tardia. Utilizou-se fio de polipropileno de tripla convergncia para a correção do desvio da hemiface paralisada. Trata-se de fio monofilamentar, sinttico, transparente e inabsorvvel que possui garras que tracionam os tecidos ptosados mantendo-os na posio correta, em simetria com o lado so. Os resultados foram avaliados atravs de anlise subjetiva, quanto ao grau de satisfao dos pacientes, submetidos a um questionrio prprio. RESULTADOS: Analisou-se 34 pacientes, 73,52% deles relataram grande melhora, 20,58% relataram melhora moderada e 5,88%, uma melhora leve; encontrou-se um alto ndice de satisfao, 94,1%. Dois pacientes apresentaram extruso parcial do fio. Nenhum paciente desenvolveu infeco. CONCLUSO: O emprego do fio de polipropileno de autossustentao de tripla convergncia para a correção do desvio da hemiface, consequente paralisia facial, ocasionou acentuada melhora da assimetria facial e a recuperao da autoestima dos pacientes.