122 resultados para Determination of associated parameters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this work were to analyze seeds from 20 trees of aroeira (Myracrodruon urundeuva Fr. All.) of a natural population located in the region of Selvíria, State of Mato Grosso do Sul, Brazil, in order to evaluate their protein, lipid and carbohydrate contents, and to estimate their genetic variation. A completely randomized experimental design consisting of 20 treatments (families) was set up, with two replications. Four types of proteins were detected: albumin (35.0 to 107.3 mg/g seed), globulin (3.4 to 9.3 mg/g), prolamin (60.0 to 135.2 mg/g) and glutelin (118.0 to 286.0 mg/g). The lipid content varied between 200 and 334 mg/g seed. The total sugars also varied (26.5 to 46.3 mg/g seed), with a predominance of polyols (arabinitol, mannitol, glucitol and xylitol). The main monosaccharides detected were glucose and arabinose. Total hydrolysis of the sugars indicated the presence of neutral arabinan and xylan oligosaccharides. The starch content varied from 0.35 to 1.58 mg/g seed. These biochemical traits showed considerable genetic variability, indicating that only the collection of seeds from many different trees can provide a representative sample of the population for conservation and genetic improvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Apparently, there are no custard apple cultivars defined for the northeastern region of Brazil. The establishment of breeding programs aimed at the selection of types from productive locations for later cloning is desirable. This work's objective was to evaluate the yield (during the first three crops) and quality (first crop) of fruits from 20 half-sibling custard apple tree progenies, selected from home orchards. An additional objective was to estimate genetic parameters for the traits evaluated. A micro sprinkling-irrigated experiment was conducted in Mossoró-RN, Brazil, as random blocks with five replications. In characteristics evaluated for periods longer than a year (diameter, height and mean weight of fruits, number of fruits ha-1 and fruit yield (kg ha-1), and a split-plot design was adopted, with progenies considered as plots and annual cropping seasons as subplots. The best progenies in terms of fruit yield (A3 and A4) are not necessarily the best for fruit dimensions and fruit mean weight (A2, FE4, JG1, JG2, SM1, SM7, and SM8). These progenies show great potential to be used in future studies on crosses or on vegetative propagation. In this regard, progeny JG2 should be highlighted as promising in terms of yield and fruit size. The progenies are not different with regard to percentages (in relation to mean fruit mass) of pericarp, endocarp, seeds, and receptacle, in the fruit, and fruit volume, number of seeds/fruit, and total soluble solids content in the fruit pulp, but progeny FE4 presents higher total titratable acidity in the fruit pulp. Narrow-sense heritability estimates were relatively high for all characteristics in which there was variability between progenies, with higher values for number of fruits ha-1 (80 %) and fruit yield (78 %). Relatively high coefficients of genotypic variation (around 20%) were observed for number of fruits ha-1 and fruit yield, with lower values for the other characteristics. There were positive genotypic and phenotypic correlations between fruit diameter (FD) and fruit height, FD and mean fruit weight, and number of fruits ha-1 and fruit yield.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractObjective:The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients' body mass index.Materials and Methods:The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality.Results:An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes.Conclusion:The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple spectrophotometric method is proposed for the determination of cefaclor. The method involves alkaline hydrolysis of the drug in ammonia buffer solution at pH 10 to yield diketopiperazine-2,5-dione derivative and subsequent measurement at 340 nm. Beer's law is obeyed in the concentration range 1.8 - 55 mg/mL. The proposed method was successfully applied to the determination of cefaclor in pharmaceutical formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study reports details of the stoichiometric characterization of the mixed complex system, V(H2O2)PAR, formed when vanadium adequately reacts with hydrogen peroxide and with 4-(2-Pyridilazo)Resorcinol. Also the presence of polynuclear species was investigated in order to elucidate about unambiguous assignment of the molar absorptivity, stability constant and composition of the complex. Two mathematical treatments methods of the experimental results were employed. From the results it can be concluded that this system corresponds to a mononuclear complex with 1:1:1 stoichiometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method has been developed for determining the content of mixtures of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), the HMX/RDX ratio, in explosive compositions by Fourier transform infrared spectroscopy (FT-IR), in the regions MIR (mid infrared) and NIR (near infrared) with reference values obtained by chromatographic analysis (HPLC). Plots of relative MIR (A917 / A783) or NIR absorbance values (A4412 / A4317) versus HMX/RDX ratio determined by HPLC analysis revealed good linear relationships.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantification limits of the method were of 0.05 and 0.1 mg kg-1, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zidovudine (AZT) and stavudine (D4T) are nucleoside reverse transcriptase inhibitors extensively used in human immunodeficiency virus (HIV) infected patients. In order to evaluate the quality of these drugs, two stability indicating HPLC methods were developed. The validated methods were applied in quantitative determination of AZT, D4T and their induced degradation products in capsule preparations. The stability studies were conducted at controlled temperature and relative humidity conditions based on the International Conference on Harmonization stability studies protocol for Zone IV areas. Easy sample preparation and low-cost make these methods especially useful for quality control and stability studies of AZT and D4T in drug products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is proposed for the determination of the moisture content of aromatic plants. This method is based on the co-distillation of the starting material in a modified Clevenger apparatus with four organic solvents (toluene, cyclohexane, dichloromethane and carbon tetrachloride). The results were compared with those obtained by oven drying at 105 ºC and steam distillation of the essential oil. The efficiencies of the methods were shown to be equivalent. The solvent distillation method was more practical, especially with respect to operating time (2 h).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical study based on extraction with acetonitrile-water, immunoaffinity column cleanup, and HPLC/fluorescence detection for separation and identification of ochratoxin A in coriander was carried out. Validation of the applied methodology was done through accuracy and precision studies. Homogenized samples of coriander were spiked in triplicate with ochratoxin A at 0.5, 1.0, 2.0, and 5.0 µg/kg levels. Recovery values were in the range of 98% for a fortification level at 0.5 µg/kg to 109.1% at 1.0 µg/kg. Application to coriander samples available in Portuguese markes showed no contamination with ochratoxin A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Honey is a food used since the most remote times, appreciated for its characteristic flavor, considerable nutritional value and medicinal properties; however, little information exists about the presence of chemical elements in it. The objectives of this work were to determine the chemical elements present in 38 honey samples, collected directly from beekeepers from the State of Piauí, Brazil and to verify whether they presented any contamination. The chemical elements were determined by means of Total Reflection X-ray Fluorescence. The means of three replicates were: K (109.671 ± 17.487), Ca (14.471 ± 3.8797), Ti (0.112 ± 0.07), Cr (0.196 ± 0.11), Mn (0.493 ± 0.103), Fe (1.722 ± 0.446), Co (0.038), Ni (0.728 ± 0.706), Cu (0.179 ± 0.0471), Zn (0.967 ± 0.653), Se (not detected), Br (not detected), Rb (0.371 ± 0.097), Sr (0.145 ± 0.45), Ba (11.681), Hg (not detected), and Pb (0.863) µg g-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.