169 resultados para quantitative reversed-phase high-performance liquid chromatography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbamazepine, phenobarbital and phenytoin were determined in dried blood spots (DBS) by high performance liquid chromatography, after extraction of 8 mm DBS using a mixture of acetonitrile and methanol. Analytes were separated by reversed-phase chromatography, with a run time of 17 minutes. Intra-assay and inter-assay precisions were in the 5.3 to 8.4% and 3.3 to 5.2% ranges, respectively. Accuracy was in the 98.8 to 104.3% range. The method had sensitivity to detect all analytes at levels below minimum therapeutic concentrations. The analytes were stable at 4 ºC and room temperature for up to 12 days and at 45 ºC for 9 days. The method was applied to 14 paired clinical samples of blood serum and DBS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study aims to verify the best method for a rapid and efficient extraction of flavonoids from Alpinia zerumbet. Dried leaves were extracted using distillated water and ethanol 70% by extraction methods of shaking maceration, ultrasonic, microwave and stirring. By the application of TLC and reversed-phase HPLC techniques the rutin and kaempferol-3-O-glucuronide were detected. Ethanol 70% was more efficient for flavonoids extraction than water. No significant yielding variation was verified for ultrasonic, microwave and stirring methods using ethanol 70% (11 to 14%). The relative concentration of rutin and kaempferol-3-O-glucuronide, respectively, was higher by ultrasonic (1.5 and 5.62 mg g-1 dried leaves, respectively) and by microwave (1.0 and 6.64 mg g-1 dried leaves) methods using ethanol. Rapid and simplified extraction proceeding optimize phytochemical work and acquisition of secondary metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study aims to verify the best method for a rapid and efficient extraction of flavonoids from Alpinia zerumbet. Dried leaves were extracted using distillated water and ethanol 70% by extraction methods of shaking maceration, ultrasonic, microwave and stirring. By the application of TLC and reversed-phase HPLC techniques the rutin and kaempferol-3-O-glucuronide were detected. Ethanol 70% was more efficient for flavonoids extraction than water. No significant yielding variation was verified for ultrasonic, microwave and stirring methods using ethanol 70% (11 to 14%). Relative concentration of rutin and kaempferol-3-O-glucuronide, respectively, was higher by ultrasonic (1.5 and 5.62 mg g-1 dried leaves) and by microwave (1.0 and 6.64 mg g-1 dried leaves) methods using 70% ethanol. Rapid and simplified extraction proceeding optimize phytochemical work and acquisition of secondary metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The freshwater snail Biomphalaria glabrata is an intermediate host of the trematode Schistosoma mansoni. However, some strains of B. glabrata are resistant to successful infection by S. mansoni larvae. The present work examines the profile of organic acids present in S. mansoni-resistant and -susceptible strains of B. glabrata, in order to determine whether the type of organic acid present is related to susceptibility. The organic acids were extracted from the hemolymph of two susceptible B. glabrata strains (PR, Puerto Rico and Ba, Jacobina-Bahia from Brazil), and from the resistant strains 13-16-R1 and 10R2, using solid phase extraction procedures followed by high performance liquid chromatography. The organic acids obtained were analyzed and identified by comparison with known standards. Pyruvate, lactate, succinate, malate, fumarate, acetate, propionate, ß-hydroxybutyrate and acetoacetate were detected in all hemolymph samples. Under standard conditions, the concentration of each of these substances varied among the strains tested and appeared to be specific for each strain. An interesting variation was the low concentration of pyruvate in the hemolymph of PR-snails. Only the concentration of fumarate was consistently different (p£ 0.05) between resistant and susceptible strains

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effect of somatic cell counts (SCC) in casein fractions of ultra high temperature (UHT) milk. Raw milks were categorized in SCC groups of low (200,000-320,000 cells mL-1), intermediate (380,000-560,000 cells mL-1) and high cells (600,000-800,000 cells mL-1). Five replicates of UHT milks within each SCC category were analyzed for casein fractions after 8, 30, 60, 90 and 120 days of storage through high performance liquid chromatography. SCC showed effect only on beta-casein reduction. SCC in raw milk increases the proteolysis of UHT milk, as a consequence of beta-casein degradation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of 60Co ionizing radiations in doses of 0, 75, 100, 150, 200 and 250Gy on garlic, upon the alpha-tocopherol concentration were studied. The alpha-tocopherol contents were established by high performance liquid chromatography (HPLC), after direct hexane extraction from the garlic samples. The alpha-tocopherol was determined through normal-phase column, and mobile phase was composed by hexane: iso-propyl alcohol (99:01 v/v), with 2mL/min flow rate and fluorescence detector. It is statistically shown that an irradiation dose of up to 150 Gy does not affect the garlic alpha-tocopherol content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic dyes were determined by high performance liquid chromatography in 76 samples of regular jelly and diet jelly powders, of several flavors produced by seven different manufacturers. Three sample of each product, from different batches, were analyzed. The same qualitative composition was observed for products of the same flavor from different manufacturers, but the quantitative composition varied markedly from one manufacturer to the other. There were no or few significant differences between batches from a given manufacturer, demonstrating good quality control in the use of these additives by the food industry. None of the samples exceeded the limit stipulated by Brazilian legislation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high performance liquid chromatography method was developed to quantify lamivudine, stavudine and nevirapine combined in tablets. The separation was carried out in less than 10 min using a phosphate buffer of pH 3.0 and acetonitrile (75:25, v/v) as mobile phase, a LiChrospher ODS column and UV detection at 266 nm. The method was linear over the range of 15-135 µg/mL (lamivudine), 4-36 µg/mL (stavudine) and 20-180 µg/mL (nevirapine). The accuracy ranged from 98.56 to 102.04% and intra-day and inter-day precision was less than 1% for the three drugs. The method showed robustness, remaining unaffected by deliberate variations in relevant parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analytical method of high performance liquid chromatography (HPLC) for the assay of benznidazole in tablets was developed and validated following the requirements of regulatory agencies. The method used as mobile phase acetonitrile:wather 1:1, a C18 column of 12.5 cm length x 4 mm id, 5 mm particles and lambda=316 nm. The statistical analysis of the results demonstrated that the method satisfies all parameters so as to be considered a safe and efficient analytical alternative of low cost for laboratory routine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical methodology for simultaneous determination of mebendazole and thiabendazole, two benzimidazoles used as anthelmintics. The method was based on high performance liquid chromatography, using a C18 column, a mobile phase composed of KH2PO4 0.05 mol L-1 and methanol 40:60 (v/v) and UV detection at 312 nm. The results showed that the method presented linearity from 60.0 to 140.0 µg mL-1 for mebendazole and from 99.6 to 232.4 g µL-1 for thiabendazole and it was considered selective, accurate, precise and robust according to the specific resolution from ANVISA, the Brazilian regulatory agency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the exposure of wells and surface water to pesticides, commonly used for tobacco cropping, was assessed. Water consumption wells and surface water flows were sampled at different times. After a preconcentration step with solid phase extraction (SPE), the selected pesticides were determined by gas chromatography with electron capture detection (GC-ECD) or high performance liquid chromatography with diode array detection (HPLC-DAD). No pesticides were detected in the well water samples and surface water flow in the winter season. However, in the spring and summer higher concentrations of chlorpyrifos and imidacloprid were found in the water source samples. Atrazine, simazine and clomazone were also found. The occurrence of pesticides in collected water samples was related with the application to tobacco.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical method has been developed and validated for the quantitation of lamivudine, zidovudine and nevirapine in the fixed-dose combination film-coated tablet by high performance liquid chromatography, in accordance with RE No. 899/2003, National Sanitary Surveillance Agency. It was based on an isocratic elution system with a potassium phosphate buffer pH 3.0: acetonitrile (60:40 v/v) mobile phase, C18, 250 x 46 mm column, 10µm particle size, λ 270 nm. The statistically evaluated results have shown that the method is specific, precise, accurate, and robust, ensuring the analytical safety of 3TC, AZT and NVP determination, which emerges as a new therapeutic alternative for antiretroviral treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, different solutions to extract vitamin C were tested. High-performance liquid chromatography was chosen and the conditions were based on isocratic elution in reverse phase column. Dehydroascorbic acid was determined indirectly after its reduction using dithiothreitol. The use of metaphosphoric acid to stabilize the vitamin C was shown to be required and it was necessary to neutralize the pH of the extract to apply dithiothreitol. The average recovery was 90% in collard and tomato samples. The presence of oil did not interfere in extraction and the methodology can be used to analyze stir fried vegetables.