134 resultados para polishing filtration
Resumo:
Objective: To determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and Methods: Ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: The correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: The interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated.
Resumo:
A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.
Desenvolvimento de um sistema de filtração e titulação para determinação da acidez de ácidos húmicos
Resumo:
The acidity determinations method of humic acids (HA) content was developed by Schnitzer and Gupta and is a very well known procedure. Nevertheless, care is necessary to prevent measure errors due to non-controlled BaCO3 production, during the filtration and titration of HA total acidity. To overcome this problem, we developed in our laboratory a simple filtration and titration system for the determination of HA acidity under inert atmosphere. This system enables a better reproducibility and accuracy of total, carboxylic and phenolic acidity measures than those by Schnitzer and Gupta method.
Resumo:
This paper presents an automatic procedure employing a reagent in the form of a slurry in a flow-injection system. The feasibility of the proposal is demonstrated by sulphate determination in water using the Barium Chloranilate method, which is based on the precipitation of barium sulphate. The release of a stoichiometric amount of highly colored chloranilic ions is monitored at 528 nm. The reaction is carried out in alcoholic medium in order to reduce the solubility of the reagent. A considerable improvement in the sensitivity is attained by adding ferric ions to the released chloranilic ions. An on-line filtration step to separate the excess reagent from the released chloranilic ions was necessary. In addition, a column containing a cation exchange resin was included in the manifold to remove potentially interfering ions. The proposed procedure is suitable for 30 determinations per hour and the relative standard deviation is less than 2%. The analytical curve is linear between 0.0 and 40 mg L-1 and the determination limit is about 2.0 mg L-1SO4(2-). Accuracy was confirmed by running several samples already analysed by a standard turbidimetric procedure.
Resumo:
In this work, the fruit extracts of Morus nigra - mulberry, Syzygium cuminii - jambolão, Vitis vinifera ¾ grape, Myrciaria cauliflora - jabuticaba are suggested as pH indicators in the form of either solutions or paper. The pH indicator solutions were prepared by soaking the fruits or their peels in ethanol 1:3 (m/V) for 24 h, followed by simple filtration. The pH indicator papers were prepared by imersion of the qualitative filter paper strips in the pH indicator solutions. The different pH leads to color changes in the indicator solutions or papers and it can be used for teaching elementary chemistry concepts.
Resumo:
The abatement of recalcitrant lignin macromolecules from effluents of pulp and paper industry was investigated by combined process. Flocculation and coagulation with aluminum sulfate and natural polyelectrolytes extracted from cactus Cereus peruvianus were used in the first step. After separation of solid residues by filtration, the photochemical methods using TiO2 as catalyst were employed for photocatalytic degradation of lignin compounds from solution. The abatement of lignin compounds after flocculation and coagulation was 46%, and after the overall process, the pollutants reduction observed were 66%. The remaining organic compounds may be removed by any biological treatment.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.
Resumo:
The aim of this work is to present the new applications of membrane technology in fat and oil processing, with emphasis on development and applications of the enzymatic membrane reactor and its association with extraction and purification technology by supercritical fluids (SCF). Combining the extraction by SCFs and the separation by membranes allows the integration of extractions reactions with selective separation by membranes through filtration of the supercritical mixture (SCF + extracted solutes). This association provides important energy savings regarding the SCF recompression costs.
Resumo:
Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.
Purificação e caracterização de uma gentioexaose obtida de botriosferana por hidrólise ácida parcial
Resumo:
A hexa-oligosaccharide was obtained by partial acid hydrolysis from botryosphaeran, an exopolysaccharide (EPS) β(1→3; 1→6)-D-glucan type, produced by the ascomyceteous fungus Botryosphaeria rhodina. The oligosaccharide was purified by gel filtration and charcoal-Celite column chromatography and the analysis was followed by HPAEC/PAD. The structure was determined by NMR spectroscopy and mass spectrometry, which showed that the oligosaccharide consists of six β-D-glucopiranosyl units O-6 substituted (gentiohexaose).
Resumo:
Previous studies indicated that free radicals control organic matter redox activities. In the present study, organic matter of an ultra-filtrated material collected from seven samples taken seasonally from the Paraiba do Sul River for two years were titrated with an oxidizer (I2) in an inert atmosphere. Standard formal potential values for the electrode MO Ox, MO Red ranged from 0.754 to 0.786 V at a 25 ºC temperature. Organic matter oxidation capacity (COx) per carbon mass varied according to pH values, and changes in COx were related to rainfall and river flow intensities.
Resumo:
The aim of this study was to verify the influence of the apparent molecular size of aquatic humic substances on the effectiveness of coagulation with ferric chloride. Coagulation-filtration tests using jar test and bench-scale sand filters were carried out on samples of water with true color of approximately 100 Hazen units, prepared with aquatic humic substances of different molecular sizes (F1: < 0.45 µm, F2: 100 kDa - 0.45 µm, F3: 30 - 100 kDa and F4': < 30 kDa). For the water samples with lower apparent molecular size fractions, greater dosages of coagulant was needed to remove the color around 5.0 Hanzen units, mainly because these water samples contain higher concentrations of fulvic acids, which exhibited a larger number of negatively-charged groups.
Resumo:
This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.
Resumo:
The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.
Resumo:
Monitoring of sewage sludge has proved the presence of many polar anthropogenic pollutants since LC/MS techniques came into routine use. While advanced techniques may improve characterizations, flawed sample processing procedures, however, may disturb or disguise the presence and fate of many target compounds present in this type of complex matrix before analytical process starts. Freeze-drying or oven-drying, in combination with centrifugation or filtration as sample processing techniques were performed followed by visual pattern recognition of target compounds for assessment of pretreatment processes. The results shown that oven-drying affected the sludge characterization, while freeze-drying led to less analytical misinterpretations.