104 resultados para flow injection analysis


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Different methods have been applied to solve special problems of metal analysis. First, the solid samples of tool steels were analyzed by X-ray fluorescence. Alternatively, an on-line electrodissolution implemented in a flow injection system and conventional dissolution procedure for determination of W, Mo, V and Cr in tool steels by ICP-AES is described. The resulting analyte solutions were compared with conventional dissolution procedure and determination by ICP-AES. The electrolytic procedure presented a good performance characterized by a sample throughput of 164 determinations per hour. Results were in agreement with those obtained by conventional acid dissolution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to evaluate a flow injection system for determination of residual CO3(2-) in soil amended with lime material. It was used a closed system were the CO2 released from soil sample acidified with 0.5 mol L-1 HCl was capted in a 0.2 mol L-1 NaOH solution. After 16h the capted CO2 was determined by conductivimetry using a flow injection system. The results obtained by the proposed method were significantly correlated with those reported in soil samples used by the International Soil Analytical Exchange Programe. The regression equation was: y = 0.987x -- 0.075 r = 0.996, P > 0.01. For acid soils amended with CaCO3 the method showed a deviation error of 2.7%, detection limit was 0.077 mmol kg-1 of CO3(2-), and a recovery of 99.7% of the total CO3(2-) added in soil sample. The method was easily adapted for routine determination of residual CO3(2-) in soil samples with an analytical frequency of 40 samples per hour.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aquarium air pumps are proposed and evaluated as pneumatic liquid propulsion devices for flow injection and continuos flow analysis (FIA and CFA) systems. This kind of pump is widely available at a very low cost and it can sustain a pressure around of 4 psi (0.28 bar) indefinitely. By applying this air pressure onto a solution contained in a reservoir flask, it is possible to reach flow rates of up to 12.5 mL min-1 for circuits comprising reactors, made from 0.8 i.d. tubing with a length of 100 cm. The precise adjustment of flow rate below the maximum one can be made with a simplified needle valve or inserting in series a short length of capillary tube. The absence of flow pulsation is a definite advantage in comparison with peristaltic pumps, especially when amperometric detection is elected, as confirmed experimentally in FIA and CF applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A digital multimeter (~U$ 240.00 on the national market) connected to a microcomputer by a RS-232 serial interface is proposed for data acquisition in equipment with analog output. Data are measured at the rate of 2 points per second and stored in text files by the software that accompanies the device, running in a Windows environment. The performance of the multimeter was verified by monitoring the transient signals generated in flow injection systems associated with fluorimetric, spectrophotometric and flame photometric detection. In addition, the performance of the proposed device was similar to that attained by employing an interface card with a 12-bit analog-to-digital converter for acquisition of the signals generated by a capillary electrophoresis equipment with oscillometric detection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An experiment is proposed to introduce some fundamentals of flow analysis, chemiluminescence and kinetic monitoring of enzymatic reactions in undergraduate courses. Chemiluminescence detection is performed with a simple spectrophotometer equipped with a lab-made spiral flow cell constructed from a polyethylene tube. The hydrogen peroxide produced by the glucose oxidation in the presence of glucose oxidase is continuously monitored by the reaction with luminol in alkaline media in a flow injection system. The exercise allows also the discussion of important analytical features and the comparison with different optical methods of analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Immunoassay techniques provide simple, powerful and inexpensive methods for analysis of environmental contaminants. However, the acceptance of immunoassays is dependent on the clear demonstration of quality and validity compared to more traditional techniques. In this review, primarily, the understanding and the fundamentals of immunoassay methods are given in order to make good use of immunoassays, especially of EIA tests. Special attention is given to the concepts related to the enzyme-linked immunosorbent assay (ELISA) formats, such as inhibition concentration at 50% (IC50), detection limit (LOD), cross-reactivity (CR %). It is also explained why some immunoassays are quantitative methods whereas others can only be used as screening methods. A list of main commercial kits for detection of priority pollutants is given in order to help analysts. Others formats, such as flow-injection immunoassay analysis (FIIA), immunoassay chromatography and immunosensors are also cited.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The year of 2010 marks the 20th anniversary of the development of Sequential Injection Analysis (SIA) by Ruzicka and Marshall. Considered the second generation of the flow injection methods, this article briefly describes the history, the basic principles of the technique and reviews all papers developed by Brazilian scientists aiming the divulgation of this automation technique in Analytical Chemistry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study optimized and validated a method to perform chemical speciation of inorganic arsenic in water samples collected under the Monitoring Program of the Port of Rio Grande-RS in July and October 2010 from the Laguna dos Patos Estuary (RS, Brazil). The flow injection hydride generation atomic absorption spectrometry technique was employed, allowing quantification of As3+ and As5+ present in estuarine water samples. Data interpretation for results generated using the improved method for analyzing water samples collected from Laguna dos Patos Estuary was done by main components analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Determination of the viability of bacteria by the conventional plating technique is a time-consuming process. Methods based on enzyme activity or membrane integrity are much faster and may be good alternatives. Assessment of the viability of suspensions of the plant pathogenic bacterium Clavibacter michiganensis subsp. michiganensis (Cmm) using the fluorescent probes Calcein acetoxy methyl ester (Calcein AM), carboxyfluorescein diacetate (cFDA), and propidium iodide (PI) in combination with flow cytometry was evaluated. Heat-treated and viable (non-treated) Cmm cells labeled with Calcein AM, cFDA, PI, or combinations of Calcein AM and cFDA with PI, could be distinguished based on their fluorescence intensity in flow cytometry analysis. Non-treated cells showed relatively high green fluorescence levels due to staining with either Calcein AM or cFDA, whereas damaged cells (heat-treated) showed high red fluorescence levels due to staining with PI. Flow cytometry also allowed a rapid quantification of viable Cmm cells labeled with Calcein AM or cFDA and heat-treated cells labeled with PI. Therefore, the application of flow cytometry in combination with fluorescent probes appears to be a promising technique for assessing viability of Cmm cells when cells are labeled with Calcein AM or the combination of Calcein AM with PI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several studies have recently shown the use of recombinant rabies virus as potential vector-viral vaccine for HIV-1. The sequence homology between gp 120 and rabies virus glycoprotein has been reported. The McCoy cell line has therefore been used to show CD4+ or CD4+ like receptors. Samples of HIV-1 were isolated, when plasma of HIV-1 positive patients was inoculated in the McCoy cell line. The virus infection was then studied during successive virus passages. The proteins released in the extra cellular medium were checked for protein activity, by exposure to SDS Electrophoresis and blotting to nitro-cellulose filter, then reacting with sera of HIV positive and negative patients. Successive passages were performed, and showed viral replication, membrane permeabilization, the syncytium formation, and the cellular lysis (cytopathic effect). Flow cytometry analysis shows clear evidence that CD4+ receptors are present in this cell line, which enhances the likelihood of easy isolation and replication of HIV. The results observed allow the use of this cell line as a possible model for isolating HIV, as well as for carrying out studies of the dynamics of viral infection in several situations, including exposure to drugs in pharmacological studies, and possibly studies and analyses of the immune response in vaccine therapies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The yield as well as phenotypic and functional parameters of canine peripheral blood monocyte-derived macrophages were analyzed. The cells that remained adherent to Teflon after 10 days of culture had high phagocytic activity when inoculated with Leishmania chagasi. Flow cytometric analysis demonstrated that more than 80% of cultured cells were positive for the monocyte/macrophage marker CD14.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An important cytokine role in dengue fever pathogenesis has been described. These molecules can be associated with haemorrhagic manifestations, coagulation disorders, hypotension and shock, all symptoms implicated in vascular permeability and disease worsening conditions. Several immunological diseases have been treated by cytokine modulation and dexamethasone is utilized clinically to treat pathologies with inflammatory and autoimmune ethiologies. We established an in vitro model with human monocytes infected by dengue virus-2 for evaluating immunomodulatory and antiviral activities of potential pharmaceutical products. Flow cytometry analysis demonstrated significant dengue antigen detection in target cells two days after infection. TNF-alpha, IFN-alpha, IL-6 and IL-10 are produced by in vitro infected monocytes and are significantly detected in cell culture supernatants by multiplex microbead immunoassay. Dexamethasone action was tested for the first time for its modulation in dengue infection, presenting optimistic results in both decreasing cell infection rates and inhibiting TNF-alpha, IFN-alpha and IL-10 production. This model is proposed for novel drug trials yet to be applyed for dengue fever.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We assessed fluconazole susceptibility in 52 Candida tropicalis clinical strains using seven antifungal susceptibility methods, including broth microdilution (BMD) [standard M27 A3 (with neutral and acid pH), ATB Fungus 3, Vitek 2 system and flow cytometric analysis] and agar-based methods (disk diffusion and E-test). Trailing growth, detection of cell-associated secreted aspartic proteases (Saps) and morphological and ultrastructural traits of these clinical strains were also examined. The ranges of fluconazole 24 h-minimum inhibitory concentration (MIC) values were similar among all methods. The essential agreement among the methods used for MIC determinations was excellent and all methods categorised all strains as susceptible, except for one strain that showed a minor error. The presence of the trailing effect was assessed by six methods. Trailing positivity was observed for 86.5-100% of the strains. The exception was the BMD-Ac method where trailing growth was not observed. Morphological and ultrastructural alterations were detected in C. tropicalis trailing cells, including mitochondrial swelling and cell walls with irregular shapes. We tested the production of Saps in 13 C. tropicalis strains expressing trailing growth through flow cytometry. Our results showed that all of the C. tropicalis strains up-regulated surface Sap expression after 24 h or 48 h of exposure to fluconazole, which was not observed in untreated yeast strains. We concluded that C. tropicalis strains expressing trailing growth presented some particular features on both biological and ultrastructural levels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5) and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level).