93 resultados para fast sample preparation method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anodic electrodissolution procedure in a flow injection system for determination of constituents in alloys is discussed. This approach implement sample preparation procedure by using a chamber and a DC power supply with constant direct current. Solid sample was attached to chamber as anode. In this review a general overview of these procedure is presented. The procedure presented a good performance characterized by a high sample throughput determinations, good accuracy and relative standard deviation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundamental aspects of Solid Phase Micro-Extraction (SPME) are discussed in the present paper. The application of SPME as a microtechnique of sample preparation for gas chromatographic analysis is considered and related to existing theoretical models. Both research prototypes and commercial SPME devices are considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate a flow injection system for determination of residual CO3(2-) in soil amended with lime material. It was used a closed system were the CO2 released from soil sample acidified with 0.5 mol L-1 HCl was capted in a 0.2 mol L-1 NaOH solution. After 16h the capted CO2 was determined by conductivimetry using a flow injection system. The results obtained by the proposed method were significantly correlated with those reported in soil samples used by the International Soil Analytical Exchange Programe. The regression equation was: y = 0.987x -- 0.075 r = 0.996, P > 0.01. For acid soils amended with CaCO3 the method showed a deviation error of 2.7%, detection limit was 0.077 mmol kg-1 of CO3(2-), and a recovery of 99.7% of the total CO3(2-) added in soil sample. The method was easily adapted for routine determination of residual CO3(2-) in soil samples with an analytical frequency of 40 samples per hour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Calculation of uncertainty of results represents the new paradigm in the area of the quality of measurements in laboratories. The guidance on the Expression of Uncertainty in Measurement of the ISO / International Organization for Standardization assumes that the analyst is being asked to give a parameter that characterizes the range of the values that could reasonably be associated with the result of the measurement. In practice, the uncertainty of the analytical result may arise from many possible sources: sampling, sample preparation, matrix effects, equipments, standards and reference materials, among others. This paper suggests a procedure for calculation of uncertainties components of an analytical result due to sample preparation (uncertainty of weights and volumetric equipment) and instrument analytical signal (calibration uncertainty). A numerical example is carefully explained based on measurements obtained for cadmium determination by flame atomic absorption spectrophotometry. Results obtained for components of total uncertainty showed that the main contribution to the analytical result was the calibration procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromium and potassium-doped iron oxides are widely used as industrial catalysts in the dehydrogenation of ethylbenzene to produce styrene. They have several advantages but deactivate with time, because of the loss of potassium. Also, they are toxic due to chromium compounds. Therefore there is a need for developing alternative non toxic catalysts without potassium. Then, iron and aluminum compounds were prepared by different methods in this work. Different phases were produced depending on the preparation method. Aluminum-doped hematite was more active and selective to styrene than the aluminum ferrite. Aluminum acts both as textural and structural promoter in the catalysts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study concerns certain problems inherent to the determination of fat-soluble vitamins in food, from extraction methods to identification and quantification. The discussion involves the main official and unofficial extraction methods coupled with spectrophotometric and HPLC techniques in which vitamins samples are obtained through liquid-liquid-solid and liquid-liquid-solid-solid extraction, indispensable to the analytical separation of different chemical compounds with vitamin functions. A saponification stage, possibly coupled with supercritical fluid extraction appears to be mandatory in the determination of vitamins A and E in their alcoholic forms. Alternative identification and quantification procedures are outlined: biological and chemical assays, analytical separations by HPLC (normal and reversed-phase), UV detection (all fat-soluble vitamins) and fluorescence detection (retinoids and tocopherols). Automation from sample preparation to quantification stages increases the data acquisition rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of organoantimonial complexes in the therapeutic of leishmaniasis and schistosomiasis has been limited mainly by the need for daily parenteral administration, their adverse side-effects and the appearance of drug resistance. Liposome encapsulation has been so far the most effective means to improve the efficacy of pentavalent antimonials against visceral leishmaniasis. Pharmacologically- and pharmaceutically-acceptable liposomal compositions are still being investigated through manipulation of preparation method, lipid composition and vesicle size. Recently, the encapsulation of a trivalent antimonial within "stealth" liposomes was found to reduce its acute toxicity and effectively deliver this compound to the parasite in experimental schistosomiasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a systematic study for bovine liver sample preparation for Cd and Pb determination by solid sampling electrothermal atomic absorption spectrometry. Samples were prepared using different procedures: (1) drying in a household microwave oven followed by drying in a stove at 60 ºC until constant mass, and (2) freeze-drying. Ball and cryogenic mills were used for grinding. Particle size, sample size and micro sample homogeneity were investigated. All prepared samples showed good homogeneity (He < 10) even for low sample mass, but samples dried in a microwave oven/stove and ground in a ball mill presented the best homogeneity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zidovudine (AZT) and stavudine (D4T) are nucleoside reverse transcriptase inhibitors extensively used in human immunodeficiency virus (HIV) infected patients. In order to evaluate the quality of these drugs, two stability indicating HPLC methods were developed. The validated methods were applied in quantitative determination of AZT, D4T and their induced degradation products in capsule preparations. The stability studies were conducted at controlled temperature and relative humidity conditions based on the International Conference on Harmonization stability studies protocol for Zone IV areas. Easy sample preparation and low-cost make these methods especially useful for quality control and stability studies of AZT and D4T in drug products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inductively Coupled Plasma Optical Emission Spectrometry was used to determine Ca, Mg, Mn, Fe, Zn and Cu in samples of processed and natural coconut water. The sample preparation consisted in a filtration step followed by a dilution. The analysis was made employing optimized instrumental parameters and the results were evaluated using methods of Pattern Recognition. The data showed common concentration values for the analytes present in processed and natural samples. Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) indicated that the samples of different kinds were statistically different when the concentrations of all the analytes were considered simultaneously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analysis of drugs and metabolites in biological fluids usually requires extraction procedures to achieve sample clean-up and analyte preconcentration. Commonly, extraction procedures are performed using liquid-liquid extraction or solid-phase extraction. Nevertheless, these extraction techniques are considered to be time-consuming and require a large amount of organic solvents. On this basis, microextraction techniques have been developed. Among them, liquid-phase microextraction has been standing out. This review describes the liquid-phase microextraction technique based on hollow fibers as a novel and promising alternative in sample preparation prior to chromatographic or electrophoretic analysis. The basic concepts related to this technique and its applicability in extraction of drugs are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel solventless sample preparation, stir-bar sorptive extraction (SBSE), for extraction, and sample enrichment of organic compounds from biological fluids, is described in this manuscript from principle to applications. The SBSE is based on sorptive extraction, whereby the compounds are extracted into a polymer coating, polydimethylsiloxane (PDMS), on a magnetic stirring rod. The extraction is controlled by the partitioning coefficient of drugs between the PDMS and sample matrix, and upon the sample-extraction medium phase ratio. The SBSE technique has been applied successfully, with high sensitivities, to biomedical analysis of volatiles and for semi-volatiles drugs from biological sample, including urine, plasma, and saliva. SBSE combined with in situ derivatization, drugs quite more polar (e.g. metabolites) also can be analyzed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the use of Raman and infrared techniques for the qualitative and quantitative analysis of plasticizers in polyvinylchloride (PVC) commercial films. FT-Raman marker bands were indentified for di-2-ethyl-hexyl adipate (DEHA) and di-2-ethyl-hexyl phthalate (DEHP), allowing for the rapid identification of these species in the commercial film. Quantitative analysis by FT-IR resulted in plasticizers concentrations ranging from 11 to 27% (w/w). Considering the little sample preparation and the low cost of the techniques, FT-IR and FT-Raman are viable techniques for a first assessment of plasticizers in commercial samples.