111 resultados para air sampling
Resumo:
The objective of this work was to evaluate sampling density on the prediction accuracy of soil orders, with high spatial resolution, in a viticultural zone of Serra Gaúcha, Southern Brazil. A digital elevation model (DEM), a cartographic base, a conventional soil map, and the Idrisi software were used. Seven predictor variables were calculated and read along with soil classes in randomly distributed points, with sampling densities of 0.5, 1, 1.5, 2, and 4 points per hectare. Data were used to train a decision tree (Gini) and three artificial neural networks: adaptive resonance theory, fuzzy ARTMap; self‑organizing map, SOM; and multi‑layer perceptron, MLP. Estimated maps were compared with the conventional soil map to calculate omission and commission errors, overall accuracy, and quantity and allocation disagreement. The decision tree was less sensitive to sampling density and had the highest accuracy and consistence. The SOM was the less sensitive and most consistent network. The MLP had a critical minimum and showed high inconsistency, whereas fuzzy ARTMap was more sensitive and less accurate. Results indicate that sampling densities used in conventional soil surveys can serve as a reference to predict soil orders in Serra Gaúcha.
Resumo:
The objective of this work was to evaluate the effects of increased air-CO2 concentration on plant growth and on leaf-spot caused by Cylindrocladium candelabrumin Eucalyptus urophylla. Seedlings were cultivated for 30 days at 451, 645, 904, and 1,147 µmol mol-1 CO2 ; then, they were inoculated with the pathogen and kept under the same conditions for seven days. Increased CO2concentration increased plant height and shoot dry matter mass, and decreased disease incidence and severity. Stem diameter was not affected by the treatments. Increased concentrations of atmospheric CO2 favorably affect eucalypt growth and reduce leaf-spot severity.
Resumo:
A study was conducted to determine the possibility of cashew (Anacardium occidentale) cloning by air-layering and influence of IBA (indol-butyric acid) on this process. It was adopted a completely randomized design with 4 treatments, 10 air layers each and 4 replications, reaching 160 air layers. The IBA levels on the treatments were, as follow: 0, 1000, 3000 and 5000 mg.kg-1. It was evaluated: survival, callus and rooting percentage, average number and length of roots. The highest survival rate (67.5%) was registered with no growth regulator and IBA at 1000 mg.kg-1, while the best rooting percentage (82%) referred to 1000 mg.kg-1. In spite of average number and length of roots, the highest results were observed with IBA at 5000 mg.kg-1. IBA concentrations had no influence on cashew air-layering formation.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
In the present paper, we report on the analytical use of a dynamic droplet based gas collection and an analysis system. A droplet formed at the tip of a tube represents a sampling approach that provides an indefinitely renewable surface and uses very little reagent. Sample gas flows past the droplet at a low flow rate. After the gas was sampled , the analysis can be carried out by different methodologies. The feasibility of the sensor is demonstrated by continuos determination of gaseous as: NO2, Cl2 and SO2.
Resumo:
The presence of low carbonyl compounds (C1-C4) and glutaraldehyde was observed in 14 work-locations in São Paulo city, Brazil, during January to July 1997 period. The quantification of other carbonyls was not possible due to a sampling artifact caused probably by undesirable reactions between the ambient ozone and the organic substract of C18 cartridge used to collect carbonyls. High indoor concentrations, compared to outdoor levels, were observed for all compounds. Formaldehyde was the most abundant species (29 ppb) followed by acetone and acetaldehyde (25 and 17 ppb) with a small contribution of propanal, crotonaldehyde and C4 isomers (0.7 to 1.5 ppb) when related to the total indoor carbonyls level. Glutaraldehyde was observed only in two different occupational locations in a hospital at high concentrations (121 ppb). In general, high individual carbonyl levels as well as total carbonyls levels found in several locations indicated an unpropitious air quality for the occupants of these non-industrial sites.
Resumo:
A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.
Comparação de duas metodologias de amostragem atmosférica com ferramenta estatística não paramétrica
Resumo:
In atmospheric aerosol sampling, it is inevitable that the air that carries particles is in motion, as a result of both externally driven wind and the sucking action of the sampler itself. High or low air flow sampling speeds may lead to significant particle size bias. The objective of this work is the validation of measurements enabling the comparison of species concentration from both air flow sampling techniques. The presence of several outliers and increase of residuals with concentration becomes obvious, requiring non-parametric methods, recommended for the handling of data which may not be normally distributed. This way, conversion factors are obtained for each of the various species under study using Kendall regression.
Resumo:
Gaseous mercury sampling conditions were optimized and a dynamic flux chamber was used to measure the air/surface exchange of mercury in some areas of the Negro river basin with different vegetal coverings. At the two forest sites (flooding and non-flooding), low mercury fluxes were observed: maximum of 3 pmol m-2 h-1 - day and minimum of -1 pmol m-2 h-1 - night. At the deforested site, the mercury fluxes were higher and always positive: maximum of 26 pmol m-2 h-1 - day and 17 pmol m-2 h-1 - night. Our results showed that deforestation could be responsible for significantly increasing soil Hg emissions, mainly because of the high soil temperatures reached at deforested sites.
Resumo:
A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.
Resumo:
This paper focuses: (i) the development of a measurement technique for the determination of atmospheric C2-C6 hydrocarbons with sampling in canisters and analysis by gas chromatography/flame ionisation detector (GC/FID), (ii) the improvement of an existent adsorption-sampling technique with Tenax TA tubes for the determination of C6-C11 hydrocarbons and analysis by GC/FID after thermal desorption and cryogenic concentration, (iii) the identification of compounds present in ambient air by gas chromatography/mass spectrometry (GC/MS) for both canister and Tenax samples, (iv) a program of interlaboratorial comparison for quality control of C2-C11 analyses, and (v) the seasonal characterisation of ambient air C2-C11 hydrocarbons.
Resumo:
This study is a result of undergraduate student participation in the Environmental Chemistry discipline provided by the Chemistry Institute/UFBA. The students were involved in the development of passive samplers, a project of the LAQUAM (Environmental Analytical Chemistry Laboratory). The students' residences and other neighborhoods were used to create a passive sampling network, allowing the measurement of atmospheric levels of pollutants in urban areas and in those under industrial influence. The assembly of the passive samplers, including impregnation of filters and chemical analysis were part of the students' practice tasks. The results were analyzed taking into consideration the Brazilian legislation.
Resumo:
The present paper constitutes a synthesis of the results gotten during the five campaigns of air quality measurement in the years of 2003 and 2004 carried out in the Portuguese city of Viana do Castelo to characterise the reference situation and to accompany the Polis Programme, an urban re-qualification and environmental valorisation plan. The main objective of the monitoring programme consisted of the evaluation of atmospheric pollutants whose levels were susceptible of enhancement in the course of the urbanistic public works. The presented results refer to measurements performed in two distinct places of this city, comprising various consecutive days of acquisition that include, at least, one day of weekend.
Resumo:
The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.