136 resultados para Ultrasound extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In general, Latosols have low levels of available P, however, the influence of the parent material seems to be decisive in defining the pool and predominant form of P in these soils. This study evaluated P availability by extraction with Mehlich-1 (M-1) and Ion Exchange Resin (IER), from samples of B horizons of Ferric and Perferric Latosols developed from different parent materials. To this end, in addition to the physical and chemical characterization of soils, 10 sequential extractions were performed with M-1 and IER from samples of B horizons (depth between 0.8 and 1.0 m). Total contents of Ca, P, Fe, Al, and Ti were determined after digestion with nitric, hydrofluoric and perchloric acids. The effects of sequential P extractions on Fe oxides were also evaluated from the analyses of dithionite-citrate-bicarbonate and ammonium acid oxalate. The high similarity between contents of P accumulated after sequential extractions with M-1 and IER in soils developed on tuffite indicated a predominance of P-Ca. Higher contents of P after a single IER extraction show greater efficiency in P removal from highly weathered soils, as from the Latosols studied here. The P contents also show the high sensitivity of extractant M-1 in highly buffered soils. Furthermore, a single extraction with extractant M-1 or IER is not sufficient to estimate the amount of labile P in these soils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mehlich-1 (M-1) extractant and Monocalcium Phosphate in acetic acid (MCPa) have mechanisms for extraction of available P and S in acidity and in ligand exchange, whether of the sulfate of the extractant by the phosphate of the soil, or of the phosphate of the extractant by the sulfate of the soil. In clayey soils, with greater P adsorption capacity, or lower remaining P (Rem-P) value, which corresponds to soils with greater Phosphate Buffer Capacity (PBC), more buffered for acidity, the initially low pH of the extractants increases over their time of contact with the soil in the direction of the pH of the soil; and the sulfate of the M-1 or the phosphate of the MCPa is adsorbed by adsorption sites occupied by these anions or not. This situation makes the extractant lose its extraction capacity, a phenomenon known as loss of extraction capacity or consumption of the extractant, the object of this study. Twenty soil samples were chosen so as to cover the range of Rem-P (0 to 60 mg L-1). Rem-P was used as a measure of the PBC. The P and S contents available from the soil samples through M-1 and MCPa, and the contents of other nutrients and of organic matter were determined. For determination of loss of extraction capacity, after the rest period, the pH and the P and S contents were measured in both the extracts-soils. Although significant, the loss of extraction capacity of the acidity of the M-1 and MCPa extractants with reduction in the Rem-P value did not have a very expressive effect. A “linear plateau” model was observed for the M-1 for discontinuous loss of extraction capacity of the P content in accordance with reduction in the concentration of the Rem-P or increase in the PBC, suggesting that a discontinuous model should also be adopted for interpretation of available P of soils with different Rem-P values. In contrast, a continuous linear response was observed between the P variables in the extract-soil and Rem-P for the MCPa extractor, which shows increasing loss of extraction capacity of this extractor with an increase in the PBC of the soil, indicating the validity of the linear relationship between the available S of the soil and the PBC, estimated by Rem-P, as currently adopted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to detect fluctuations in ruminal microbial populations due to forage tannins using 16S ribosomal RNA (rRNA) probes, recovery of intact rRNA is required. The objective of this work was to evaluate the effect of polyethylene glycol (PEG) and polyvinylpirrolidone (PVP) on extraction of bacterial rRNA, in the presence of tannins from tropical legume forages and other sources, that hybridize with oligonucleotide probes. Ruminococcus albus 8 cells were exposed to 8 g/L tannic acid or 1 g/L condensed tannins extracted from Acacia angustissima, banana (Musa sp.) skin, Desmodium ovalifolium, red grape (Vitis vinifera) skin and Inga edulis, or no tannins. Cells were rinsed with Tris buffer pH 7 containing either 8% PEG or 6% PVP prior to cell lysis. Total RNA samples rinsed with either PEG or PVP migrated through denaturing agarose gels. The 16S rRNA bands successfully hybridized with a R. albus species-specific oligonucleotide probe, regardless of tannin source. The effect of rinsing buffers on the density of 16S rRNA bands, as well as on the hybridization signals was compared. There were significant effects (P<0.01) when the controls were compared to either buffer treatments due to tannin type, buffer used and the interaction of tannin type and buffer. The significant interaction indicates the influence of tannin type on the parameters evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the influence of rootstocks and pruning times on yield and on nutrient content and extraction by pruned branches and harvested bunches of 'Niagara Rosada' grapevine in subtropical climate. The rootstocks 'IAC 766', 'IAC 572', 'IAC 313', 'IAC 571-6', and '106-8 Mgt' were evaluated. Treatments consisted of a combination between five rootstocks and three pruning times. At pruning, fresh and dry matter mass of branches were evaluated to estimate biomass accumulation. At harvest, yield was estimated by weighing of bunches per plant. Branches and bunches were sampled at pruning and at harvest, respectively, for nutrient content analysis. Nutrient content and dry matter mass of branches and bunches were used to estimate total nutrient extraction. 'Niagara Rosada' grapevine grafted onto the 'IAC 572' rootstock had the highest yield and dry matter mass of bunches, which were significantly different from the ones observed in 'Niagara Rosada'/'IAC 313'. 'Niagara Rosada' grafted onto the 'IAC 572' rootstock extracted the largest quantity of K, P, Mg, S, Cu, and Fe, differing from 'IAC 313' and 'IAC 766' in K and P extraction, and from '106-8 Mgt' in Mg and S extraction. Winter pruning results in higher yield, dry matter accumulation by branches, and total nutrient content and extraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aims to compare yield and quality of pequi pulp oil when applying two distinct processes: in the first, pulp drying in a tray dryer at 60ºC was combined with enzymatic treatment and pressing to oil extraction; in the second, a simple process was carried out by combining sun-drying pulp and pressing. In this study, raw pequi fruits were collected in Mato Grosso State, Brazil. The fruits were autoclaved at 121ºC and stored under refrigeration. An enzymatic extract with pectinase and CMCase activities was used for hydrolysis of pequi pulp, prior to oil extraction. The oil extractions were carried out by hydraulic pressing, with or without enzymatic incubation. The oil content in the pequi pulp (45% w/w) and the physicochemical characteristic of the oil was determined according to standard analytical methods. Free fatty acids, peroxide values, iodine and saponification indices were respectively 1.46 mgKOH/g, 2.98 meq/kg, 49.13 and 189.40. The acidity and peroxide values were lower than the obtained values in commercial oil samples, respectively 2.48 mgKOH/g and 5.22 meq/kg. Aqueous extraction has presented lower efficiency and higher oxidation of unsaturated fatty acids. On the other hand, pequi pulp pressing at room temperature has produced better quality oil. However its efficiency is still smaller than the combined enzymatic treatment and pressing process. This combined process promotes cellular wall hydrolysis and pulp viscosity reduction, contributing to at least 20% of oil yield increase by pressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Functional genomic analyses require intact RNA; however, Passiflora edulis leaves are rich in secondary metabolites that interfere with RNA extraction primarily by promoting oxidative processes and by precipitating with nucleic acids. This study aimed to analyse three RNA extraction methods, Concert™ Plant RNA Reagent (Invitrogen, Carlsbad, CA, USA), TRIzol® Reagent (Invitrogen) and TRIzol® Reagent (Invitrogen)/ice -commercial products specifically designed to extract RNA, and to determine which method is the most effective for extracting RNA from the leaves of passion fruit plants. In contrast to the RNA extracted using the other 2 methods, the RNA extracted using TRIzol® Reagent (Invitrogen) did not have acceptable A260/A280 and A260/A230 ratios and did not have ideal concentrations. Agarose gel electrophoresis showed a strong DNA band for all of the Concert™ method extractions but not for the TRIzol® and TRIzol®/ice methods. The TRIzol® method resulted in smears during electrophoresis. Due to its low levels of DNA contamination, ideal A260/A280 and A260/A230 ratios and superior sample integrity, RNA from the TRIzol®/ice method was used for reverse transcription-polymerase chain reaction (RT-PCR), and the resulting amplicons were highly similar. We conclude that TRIzol®/ice is the preferred method for RNA extraction for P. edulis leaves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the number of punctures in fine-needle aspiration biopsies required for a safe cytological analysis of thyroid nodules. MATERIALS AND METHODS: Cross-sectional study with focus on diagnosis. The study population included 94 patients. RESULTS: The mean age of the patients participating in the study was 52 years (standard-deviation = 13.7) and 90.4% of them were women. Considering each puncture as an independent event, the first puncture has showed conclusive results in 78.7% of cases, the second, in 81.6%, and the third, in 71.8% of cases. With a view to the increasing chance of a conclusive diagnosis at each new puncture, two punctures have showed conclusive results in 89.5% of cases, and three punctures, in 90.6% of cases with at least one conclusive result. CONCLUSION: Two punctures in fine-needle aspiration biopsies of thyroid nodules have lead to diagnosis in 89.5% of cases in the study sample, suggesting that there is no need for multiple punctures to safely obtain the diagnosis of thyroid nodules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study was aimed at evaluating the contribution of transrectal prostate ultrasound in the screening for prostate neoplasias and in the guidance of prostate biopsies. Materials and Methods: Prospective study developed over a one-year period. All the patients with indication for prostate biopsy were evaluated. Regardless of PSA values, the patients underwent ultrasound in order to identify suspicious nodules (confirmed by two observers). Sextant biopsy was subsequently performed. In cases of finding suspicious nodules, an additional puncture directed to such nodules was done. Results: In a total of 155 cases the prevalence of malignancy was of 53%. Suspicious nodules were detected in 34 patients, and 25 where malignant (positive predictive value of 74%). The specificity and sensitivity for suspicious nodules were 88% and 31% respectively. Comparatively with the randomly obtained sextant specimens, the rate of findings of neoplasia was higher in the specimens obtained with puncture directed to the nodule (p = 0.032). No statistically significant difference was observed in the Gleason score for both types of specimens (p = 0.172). Conclusion: The high positive predictive value and the high rate of findings of neoplasia in specimens of suspicious nodules should be taken into consideration in the future. The authors suggest a biopsy technique similar to the one described in the present study (sextant biopsy plus puncture directed to the suspicious nodule).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To compare the accuracy of computer-aided ultrasound (US) and magnetic resonance imaging (MRI) by means of hepatorenal gradient analysis in the evaluation of nonalcoholic fatty liver disease (NAFLD) in adolescents.Materials and Methods:This prospective, cross-sectional study evaluated 50 adolescents (aged 11–17 years), including 24 obese and 26 eutrophic individuals. All adolescents underwent computer-aided US, MRI, laboratory tests, and anthropometric evaluation. Sensitivity, specificity, positive and negative predictive values and accuracy were evaluated for both imaging methods, with subsequent generation of the receiver operating characteristic (ROC) curve and calculation of the area under the ROC curve to determine the most appropriate cutoff point for the hepatorenal gradient in order to predict the degree of steatosis, utilizing MRI results as the gold-standard.Results:The obese group included 29.2% girls and 70.8% boys, and the eutrophic group, 69.2% girls and 30.8% boys. The prevalence of NAFLD corresponded to 19.2% for the eutrophic group and 83% for the obese group. The ROC curve generated for the hepatorenal gradient with a cutoff point of 13 presented 100% sensitivity and 100% specificity. As the same cutoff point was considered for the eutrophic group, false-positive results were observed in 9.5% of cases (90.5% specificity) and false-negative results in 0% (100% sensitivity).Conclusion:Computer-aided US with hepatorenal gradient calculation is a simple and noninvasive technique for semiquantitative evaluation of hepatic echogenicity and could be useful in the follow-up of adolescents with NAFLD, population screening for this disease as well as for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractThe authors review the main concepts regarding the importance of cleaning/disinfection of ultrasonography probes, aiming a better comprehension by practitioners and thus enabling strategies to establish a safe practice without compromising the quality of the examination and the operator productivity. In the context of biosafety, it is imperative to assume that contact with blood or body fluids represents a potential source of infection. Thus, in order to implement cleaning/disinfection practice, it is necessary to understand the principles of infection control, to consider the cost/benefit ratio of the measures to be implemented, and most importantly, to comprehend that such measures will not only benefit the health professional and the patient, but the society as a whole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To propose an algorithm to determine the necessity for ultrasonography-guided fine-needle aspiration (US-FNA) in preoperative axillary lymph node staging of patients with invasive breast cancer. Materials and Methods: Prospective study developed at National Cancer Institute. The study sample included 100 female patients with breast cancer referred for axillary staging by US-FNA. Results: The overall US-FNA sensitivity was set at 79.4%. The positive predictive value was calculated to be 100%, and the negative predictive value, 69.5%. The US-FNA sensitivity for lymph nodes with normal sonographic features was 0%, while for indeterminate lymph nodes it was 80% and, for suspicious lymph nodes, 90.5%. In the assessment of invasive breast tumors stages T1, T2 and T3, the sensitivity was respectively 69.6%, 83.7% and 100%. US-FNA could avoid sentinel node biopsy in 54% of cases. Conclusion: Axillary ultrasonography should be included in the preoperative staging of all patients with invasive breast cancer. The addition of US-FNA in cases of lymph nodes suspicious for malignancy may prevent more than 50% of sentinel lymphadenectomies, significantly shortening the time interval to definitive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.