119 resultados para Ultrasonography, Doppler, Transcranial


Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A avaliação da função Ventricular Direita (VD) pelo ecocardiograma em pacientes com Tromboembolismo Pulmonar (TEP) é complexa, frequentemente qualitativa; o Doppler tecidual tem sido utilizado para avaliação semiquantitativa dessa câmara, com algumas limitações. OBJETIVO: Avaliar a função do VD no TEP pelo ecocardiograma com Doppler tecidual, complementando com o peptídeo atrial natriurético (BNP). MÉTODOS: Foram estudados pacientes com TEP pelo ecocardiograma com Doppler tecidual e BNP até 24 horas do diagnóstico, obtendo-se as velocidades miocárdicas (s'), strain, strain rate e índice de performance miocárdica do VD; disfunção do VD foi iagnosticada por hipocinesia da câmara, movimento anormal septal e relação VD/VE >1. De acordo com o BNP os pacientes foram divididos em Grupo I, BNP < 50 pg/mL e Grupo II, BNP > 50 pg/mL. RESULTADOS: De 118 pacientes, 100 (60 homens, idade = 55 ± 17 anos) foram analisados; observou-se disfunção do VD em 28%, mais frequentemente no grupo II (19 vs. 9 pacientes, p < 0,001). O grupo II era mais idoso (64 ± 19 vs. 50 ± 15 anos), apresentava menor velocidade de s' (10,5 ± 3,5 vs. 13,2 ± 3,1 cm/s) e maior pressão pulmonar (48 ± 11 vs. 35 ± 11 mmHg), p < 0,001 para todos. O ponto de corte de s' para disfunção do VD foi de 10,8 cm/s (especificidade = 85%, sensibilidade = 54%), com moderada correlação entre o BNP e a onda s'(r = -0,39). CONCLUSÃO: No TEP, a disfunção do VD pelo ecocardiograma se acompanha de elevação do BNP; apesar confirmar adequadamente a presença de disfunção do VD, o Doppler tecidual apresenta sensibilidade limitada para este diagnóstico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamento: Foi demonstrado que um novo índice de Doppler Tecidual, E/(E'×S'), incluindo a proporção entre a velocidade diastólica precoce transmitral e a do anel mitral (E/E'), e a velocidade sistólica do anel mitral (S'), tem uma boa precisão como preditor da pressão de enchimento do ventrículo esquerdo. Objetivo: Investigar o valor de E/(E'×S') para prever a morte cardíaca em pacientes com insuficiência cardíaca. Métodos: Foi realizado sucessivamente o ecocardiograma em 339 pacientes hospitalizados com insuficiência cardíaca, em ritmo sinusal, após tratamento médico adequado, no momento e um mês depois da alta. O agravamento de E/(E'×S') foi definido como um aumento do valor padrão. O ponto final foi a morte cardíaca. Resultados: Durante o período de acompanhamento (35,2 ± 8,8 meses), ocorreu a morte cardíaca em 51 pacientes (15%). O melhor valor mínimo para E/(E'× S') inicial na previsão da morte cardíaca foi de 2,83 (76% de sensibilidade, 85% de especificidade). No momento da alta, 252 pacientes (74,3%) apresentaram E/(E'×S') ≤ 2,83 (grupo I), e 87 (25,7%) apresentaram E/(E'×S') > 2,83 (grupo II), respectivamente. A morte cardíaca foi significativamente maior no grupo II em relação ao grupo I (38 mortes, 43,7% contra 13 mortes, 5,15%, p < 0,001). Através da análise de regressão multivariada de Cox, incluindo as variáveis que afetaram os resultados na análise univariada, a relação E/(E'×S') no momento da alta mostrou-se o melhor preditor independente da morte cardíaca (taxa de risco = 3,09, 95% intervalo de confiança = 1,81-5,31, p = 0,001). Pacientes com E/(E'×S') > 2,83 no momento da alta e com um agravamento após um mês apresentaram o pior prognóstico (todos p < 0,05). Conclusão: Em pacientes com insuficiência cardíaca a relação E/(E'×S') é um poderoso preditor da morte cardíaca, especialmente quando esta estiver associada com o seu agravamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN) exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV) in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D), 92 patients were assessed and divided into two groups: group I (normal, n = 31) and group II (ICD/CN, n = 61). Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%), mobility of the tricuspid annulus (0.0% versus 0.0%), and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016). The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099) and pulsed Doppler (61.3% versus 68%, p = 0.141) and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%), pseudonormal pattern (0.0% versus 0.0%), and restrictive pattern (0.0% versus 0.0%) was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables), suggesting incipient changes in RV systolic function in the ICD/CN group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Heart failure is accompanied by abnormalities in ventricular-vascular interaction due to increased myocardial and arterial stiffness. Galectin-3 is a recently discovered biomarker that plays an important role in myocardial and vascular fibrosis and heart failure progression. Objectives: The aim of this study was to determine whether galectin-3 is correlated with arterial stiffening markers and impaired ventricular-arterial coupling in decompensated heart failure patients. Methods: A total of 79 inpatients with acute decompensated heart failure were evaluated. Serum galectin-3 was determined at baseline, and during admission, transthoracic echocardiography and measurements of vascular indices by Doppler ultrasonography were performed. Results: Elevated pulse wave velocity and low arterial carotid distensibility are associated with heart failure in patients with preserved ejection fraction (p = 0.04, p = 0.009). Pulse wave velocity, carotid distensibility and Young’s modulus did not correlate with serum galectin-3 levels. Conversely, raised galectin-3 levels correlated with an increased ventricular-arterial coupling ratio (Ea/Elv) p = 0.047, OR = 1.9, 95% CI (1.0‑3.6). Increased galectin-3 levels were associated with lower rates of left ventricular pressure rise in early systole (dp/dt) (p=0.018) and raised pulmonary artery pressure (p = 0.046). High galectin-3 levels (p = 0.038, HR = 3.07) and arterial pulmonary pressure (p = 0.007, HR = 1.06) were found to be independent risk factors for all-cause mortality and readmissions. Conclusions: This study showed no significant correlation between serum galectin-3 levels and arterial stiffening markers. Instead, high galectin-3 levels predicted impaired ventricular-arterial coupling. Galectin-3 may be predictive of raised pulmonary artery pressures. Elevated galectin-3 levels correlate with severe systolic dysfunction and together with pulmonary hypertension are independent markers of outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonography can reveal most of the manifestations of portal hypertension complicating hepatosplenic, schistosomiasis. However, direct demonstration of gastroesophageal varices by ultrasonography is still very difficult. An attempt was done to correlate sonographic features of portal hypertension with the degree of fibrosis to screen patients having varices and predicting their chance of bleeding. The results obtained were found to be consistent with the esophagogastric endoscopy and with history of hematemesis. Four parameters were used, size of spleen, degree of periportal fibrosis, presence of collaterals and portal vein diameter. A pilot field survey was also done adopting the same principle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Approximately 50 publications have become available in the international literature on ultrasonography in schistosomiasis in Africa. Geographically these cover Congo, Egypt, Kenya, Mali, Mauritius, Niger, Senegal, Sudan, Tanzania and East African Islands as well as Zimbabwe. Further studies are ongoing in many countries, such as Burundi, Ghana, Madagaskar and Uganda. It was shown that ultrasonography is useful in the detection of morbidity induced by schistosomiasis on an individual basis and on the community level. There is indication for varying morbidity patterns in different African foci. Post-treatment monitoring has provided evidence for reversibility of pathological lesions induced by Schistosoma (S.) haematobium and S. mansoni, even though evidence for reversibility of periportal fibrosis in adults is not yet satisfactorily substantiated. A standardized set of criteria for ultrasonographical observations has been worked out and is presently in the process of being refined. It is thus hoped that standardization will contribute to render studies in different endemic settings comparable on a global basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this population-based study was to estimate the liver morbidity attributable to Schistosoma mansoni infection by ultrasonography adopting the proposed standard protocols of the Cairo Meeting on Ultrasonography, 1991. We examined 2384 individuals representing 20 of the households of the rural population of the Ismailia Governorate, East of Delta, Egypt. Prevalence of S. mansoni and S. haematobium infections were 40.3 and 1.7 respectively. Portal tract thickening (PTT) grade 1, 2 and 3 considered diagnostic of schistosomal liver morbidity was detected in 35.1, 1.3 and 0.2 individuals respectively. Generally, ultrasonographically-detected pathological changes increased with age, but correlated with intensity of infection only in age group 20-59 years. Comparing individuals with and without S. mansoni infections in an endemic and a non-endemic community indicated no significant difference between the former and the latter in either case. In conclusion: ultrasonography had a limited value in estimating schistosomal liver morbidity in our population-based study where early grades of liver morbidly were prevalent. The criteria of diagnosing grade I portal fibrosis need to be revised as well as the staging system proposed by the Cairo Meeting on ultrasonography in schistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ANTECEDENTES: A diversidade de técnicas de mensuração esplênica pelo ultra-som Doppler (US Doppler), a falta de valores biométricos e dopplervelocimétricos dificultam a avaliação deste órgão e de suas características hemodinâmicas. OBJETIVO: Estabelecer padrões biométricos e hemodinâmicos por US-Doppler em indivíduos adultos sadios. MATERIAIS E MÉTODOS: Estudo prospectivo de 44 indivíduos sadios, sendo 19 do sexo masculino e 25 do sexo feminino, na faixa etária de 23 a 60 anos (37,4 ± 9,6). Morfometria (US modo-B): baço: eixos longitudinal (L), transversal (T) e ântero-posterior (AP); diâmetro da artéria esplênica (DAE) e diâmetro da veia esplênica (DVE). Índices morfométricos do baço: uniplanar (IBU), biplanar (IBB) e volume esplênico (VE). Dopplervelocimetria (US Doppler): a) artéria esplênica: velocidade de pico sistólico (VPS), média das velocidades máximas de fluxo (TAMax); índices de impedância vascular: índice de resistividade (IR); índice de pulsatilidade (IP); b) veia esplênica: média das velocidades máximas de fluxo (TAMax). RESULTADOS: Morfometria: L = 9,3 ± 1,3 cm; T= 3,9 ± 0,7 cm; AP = 8,4 ± 1,2 cm; DAE = 0,3 ± 0,07 cm; DVE: 0,5 ± 0,12 cm. Índices morfométricos do baço: IBU = 33,5 ± 9,9; IBB = 36,7 ± 10,3; VE = 164,3 ± 62,9 cm³. Dopplervelocimetria: a) artéria esplênica: VPS = 59,8 ± 23,6 cm/s; TAMax = 40,2 ± 15,9 cm/s; IP = 0,86 ± 0,30; IR = 0,55 ± 0,09; b) veia esplênica: TAMax = 16,8 ± 8,3 cm/s. CONCLUSÃO: Relato de valores biométricos e dopplervelocimétricos do baço em indivíduos sadios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ultra-sonografia e o Doppler representaram grande marco no diagnóstico da hipertensão portal. Este fato decorre do aspecto não-invasivo destes métodos, possibilitando o estudo do fígado, do baço e da circulação esplâncnica. Neste artigo os autores discutem alguns aspectos importantes avaliados pela ultra-sonografia e pelo Doppler na avaliação da hipertensão portal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A anastomose portossistêmica intra-hepática transjugular (TIPS) compreende a técnica mais recente e mais popular para o alívio da hipertensão portal sintomática, especialmente para os casos com varizes e hemorragia digestiva alta, e menos comumente para o tratamento da ascite refratária. Os TIPS podem apresentar complicações após sua colocação, como as estenoses e oclusões. A ultra-sonografia e o Doppler permitem o estudo dos TIPS de uma forma não invasiva. Neste artigo os autores relatam os achados recentes à ultra-sonografia e ao Doppler nos casos de funcionamento normal e anormal (estenoses/oclusões) dos TIPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a capacidade da ultra-sonografia com Doppler colorido em caracterizar a vascularização de carcinomas sólidos da mama e em correlacionar padrões de vascularização com o tamanho, estádio e grau histológico destes tumores. MATERIAIS E MÉTODOS: Sessenta e seis carcinomas da mama foram estudados com Doppler colorido. As características morfológicas e fluxométricas foram avaliadas antes da biópsia e correlações com aspectos clínicos, histopatólogicos e estadiamento tumoral foram avaliadas estatisticamente. RESULTADOS: Cinqüenta e dois tumores (79%) apresentaram vasos penetrantes, 63 (95%) mostraram vasos periféricos, 33 (50%) tinham vasos centrais e em dois tumores (3%) não foi observada vascularização. O número médio de vasos nos tumores foi de 11,9 ± 7,7 e na mama contralateral foi de 1,7 ± 2,5. Nenhuma associação foi evidenciada com as características histológicas. A distribuição dos vasos foi diferente em dois grupos de tumores. Não houve diferença na velocidade diastólica, na resistência e no índice de pulsatilidade dos tumores e da mama contralateral. A velocidade sistólica nos tumores foi de 11,74 ± 0,96 e na mama contralateral foi de 9,45 ± 0,55. O número de vasos aumentou com a progressão do estadiamento dos tumores. CONCLUSÃO: O padrão vascular dos carcinomas da mama identificado pelo Doppler colorido deve ser considerado com potencial característica importante na avaliação pré-operatória destes tumores, em conjunto com outros fatores prognósticos como o tamanho tumoral e o estádio da doença.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler"). Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As malformações arteriovenosas do útero são entidades raras. Sua forma de apresentação clínica é muito diversa, devendo o ginecologista e o imaginologista estar atentos para esta possibilidade diagnóstica, para estabelecer o tratamento de forma precisa e rápida. O presente artigo visa mostrar um caso de malformação arteriovenosa uterina adquirida após doença trofoblástica gestacional, cujo diagnóstico foi bem estabelecido por meio da ultra-sonografia com Doppler colorido e correlação com angiorressonância magnética.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar, prospectivamente, qual o melhor período para a realização do Doppler das artérias uterinas na predição de complicações da gestação. MATERIAIS E MÉTODOS: Foi conduzido estudo prospectivo em 45 pacientes primigestas, sem história de doenças crônicas. O Doppler das artérias uterinas foi realizado entre 18-20, 24-26, 28-30 e 34-36 semanas, com determinação do índice de resistência, índice de pulsatilidade, relação A/B e a presença ou ausência de incisura na onda de velocidade de fluxo, assim como o resultado da gestação. RESULTADOS: Os índices Doppler apresentaram decréscimo com o decorrer da gestação, mais pronunciado nas gestações normais quando estas foram comparadas com aquelas que tiveram complicações, de maneira mais acentuada no exame realizado entre 24-26 semanas. A melhor relação entre sensibilidade e especificidade para a detecção de complicações durante a gestação foi obtida no exame realizado entre 24-26 semanas. CONCLUSÃO: O melhor período para a realização do Doppler das artérias uterinas na predição de complicações da gestação é o intervalo entre 24-26 semanas.