87 resultados para Tannery effluent


Relevância:

10.00% 10.00%

Publicador:

Resumo:

From the environmental point of view, the textile sector is outstanding for the generation of large amounts of biorecalcitrant effluents. In this paper the textile effluent biodegradability, both before and after its treatment with Fenton's Reagent, were compared by means of biologic tests. These tests showed that the Fenton treatment lowered the biodegradabilty of practically all tested effluents, except one specific effluent from a scouring bath of polyester fibers, which achieved a 93% COD removal. This removal was due to a significant phase separation (oil/water).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this investigation antioxidant response and toxicity of metals in receiving water effluent miner in the Blanco river in Pseudokirchneriella subcapitata was assessed. The catalase activity, lipid damage through Tbars, the growth rate of was determined. The result showed an inhibition of the growth rate of P. subcapitata which correlated with increased catalase activity and the lipid liperoxidation. These responses were correlated with the concentrations of copper and iron.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Food industries employ a lot of synthetic dyes in their products. Most of these dyes are very stable face to the conventional treatments. This work studied the use of advanced oxidation process (AOP) as an alternative to the conventional ones to degrade a synthetic food effluent (photolysis and UV/H2O2 in continuous reactor). The more efficient process was the UV/H2O2 and it presented decoloration and degradation energetic efficiency values equal to 30.775 kWh m-3 and 269.909 kWh m-3, respectively. The color reduction was 96.4% and COD decrease was 38.56%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of "salt". Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of "salt", 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nitrous oxide emissions from an activated sludge plant which serves a research institute in Rio de Janeiro city were estimated from six unit processes (grit tank, sand trap, aeration tank, secondary settling tank, sludge recirculation line and aerobic digester sludge tank) and also from the plant effluent. Total estimated annual flux was 3.2 x 10(4) g N2O yr-1 of which about 90% was from the aeration tank. Emission factors estimated from population served, wastewater flow and nitrogen load (conversion ratio) were 13 g N2O person-1 yr-1, 9.0 x 10-5 g N2O Lwastewater-1 and 0.14%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to analyze 17 β estradiol and estrone, natural estrogenic hormones present in domestic effluents and animal excreta, in the public water supply system of Jaboticabal, SP. The results have shown the presence of estrogens in 22% of the samples in concentrations from 6,8 ng L-1 (treated water) to 30,6 ng L-1 (riverhead) for 17 β estradiol and 600 ng L-1 of estrone (stream), respectively. We concluded that animal wastes, discharges from the wastewater treatment station, and discharges of domestic effluent without treatment from rural proprieties were probably the cause of this contamination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, TiO2 photocatalysis was used to disinfect domestic wastewaters previously treated by different biological treatment systems: Upward-flow Anaerobic Sludge Blanket (UASB), facultative pond, and duckweed pond. The microorganisms monitored were E. coli, total coliforms, Shigella species, and Salmonella species. Photocatalytic experiments were carried out using two light sources: a solar simulator (UV intensity: 68-70 W m-2) and black-light lamps (BLL UV intensity: 17-20 W m-2). Samples were taken after each treatment stage. Results indicate that bacterial photocatalytic inactivation is affected by characteristics of the effluent, including turbidity, concentration of organic matter, and bacterial concentration, which depend of the type of biological pretreatment previously used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to study spatial and seasonal variability of some chemical-physical parameters in the Turvo/Grande watershed, São Paulo State, Brazil. Water samples were taken monthly, 2007/07-2008/11, from fourteen sampling stations sited along the Turvo, Preto and Grande Rivers and its main tributaries. The Principal Component Analysis and hierarchical cluster analysis showed two distinct groups in this watershed, the first one associated for the places more impacted by domestic effluent (lower levels of dissolved oxygen in the studied region). The sampling places located to downstream (Turvo and Grande rivers) were discriminate by diffuse source of pollutants from flooding and agriculture runoffs in a second group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective was to study the treatment of wastewater generated by the oil industry. This work consisted of tests of electroflocculation with alternate current (AC), and chemical coagulation. The removal efficiencies of organic load were evaluated by the removal of oils and greases, color and turbidity. The parameters investigated were the change in alternate current frequency, the initial pH, the distance between electrodes, the applied potential and time lapse. From the results, one may conclude that the electroflocculation process is potential applicability to the effluent studied, while chemical coagulation was not successful.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The kinetics of biodegradation by the fungus Ganoderma sp of textile dyes Yellow, Blue and Red Procion were studied in effluents using UV-Vis spectroscopy, Partial Least Squares Regression (PLS) and univariate analysis. The kinetic of the reactions were founded intermediate between first and second orders and the rate constants were calculated. The biodegradation after 72 h at 28 ºC were 33.6, 43.5 and 57.7% for the dyes Yellow, Blue and Red Procion, respectively. The quantitative analysis of the effluent by HPLC method can not be used without previous separation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of biodigester for basic and environmental sanitation has large demand in Brazil. A biodigester was built to treat conjunctly the human and pig feces and urine, regarding to its future application in rural small towns. The results show that the biodigester can reduce 90% of COD and BOD and, up to 99.99% of thermotolerant coliforms. The treated effluent has variable quantities of macro- and micro-nutrients; and organic matter. However, the concentration variability of the nutrients makes difficult a dosed application into soil. The soluble salts (mainly as Na+ form) make necessary a controlled use to avoid environmental degradation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrocoagulation/flotation process was applied to treat biodiesel wastewater using aluminium electrodes. Firstly, a literature survey was conducted to choose the process variables and then, operational parameters including initial pH, electrode distance and reaction time were tested. Experimental results showed the best parameter that can be used in a factorial design for further studies. The results indicate that electrocoagulation/flotation is very efficient to reduce oil and grease, the effluent was very clear after treatment and small amount of sludge was produced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wastewaters from biodiesel production contain as primarily wastes sodium or potassium soaps, fatty acids, glycerin, alcohol and other contaminants. In general, these waters are chemically unsuitable for release to any water body, so, it is necessary the adoption of techniques for the treatment of this effluent. In this review, electrochemical, biological, physicochemical, and combined treatments reported for the removal of the wastewater containing pollutants come from biodiesel production have been summarized. In addition, the recovery, the reuse, the energy production and the synthesis of new compounds from the organic matter contained in this kind of effluent are also reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The catalytic performance of Ni/ZrO2 catalysts loaded with different lanthanum content for steam reforming of ethanol was investigated. Catalysts were characterized by BET surface area, X-ray diffraction, UV-vis spectroscopy, temperature programmed reduction, and X-ray absorption fine structure techniques. Results showed that lanthanum addition led to an increase in the degree of reduction of both NiO and nickel surface species interacting with the support, due to the higher dispersion effect. The best catalytic performance at 450 ºC was found for the Ni/12LZ catalyst, which exhibited an effluent gaseous mixture with the highest H2 yield.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the sorption and leaching of thiamethoxam in dystrophic Red-Yellow Latosol (LVAd), dystroferric Red Latosol (LVdf) and Red-Yellow Argisol (PVAd) with coffee under the effect of sewage sludge doses. There was thiamethoxam sorption decreasing at higher doses of sewage sludge in LVAd and LVdf. In the PVAd, sorption was higher in samples that received the highest dose of sewage sludge. At 150 days after the application of thiamethoxam, the compound began to be detected in the effluent, in all soils. Dissolved organic carbon had no influence on the thiamethoxam leaching.