128 resultados para Sensitivity and Specificity
Resumo:
This study aimed to evaluate the interference of tuberculin test on the gamma-interferon (INFg) assay, to estimate the sensitivity and specificity of the INFg assay in Brazilian conditions, and to simulate multiple testing using the comparative tuberculin test and the INFg assay. Three hundred-fifty cattle from two TB-free and two TB-infected herds were submitted to the comparative tuberculin test and the INFg assay. The comparative tuberculin test was performed using avian and bovine PPD. The INFg assay was performed by the BovigamTM kit (CSL Veterinary, Australia), according to the manufacturer's specifications. Sensitivity and specificity of the INFg assay were assessed by a Bayesian latent class model. These diagnostic parameters were also estimate for multiple testing. The results of INFg assay on D0 and D3 after the comparative tuberculin test were compared by the McNemar's test and kappa statistics. Results of mean optical density from INFg assay on both days were similar. Sensitivity and specificity of the INFg assay showed results varying (95% confidence intervals) from 72 to 100% and 74 to 100% respectively. Sensitivity of parallel testing was over 97.5%, while specificity of serial testing was over 99.7%. The INFg assay proved to be a very useful diagnostic method.
Resumo:
Conidiobolomycosis is a granulomatous disease caused by the fungus Conidiobolus spp. in humans and animals. Traditional technique for diagnosis of the disease is isolation of the agent associated with the presence of typical clinical signs and pathological conditions. The aim of this study was to describe the development of a specific polymerase chain reaction (PCR) test for Conidiobolus lamprauges to detect the fungus in clinical samples. Samples from suspected animals were collected and submitted to isolation, histopathological analysis and amplification by PCR. DNA from tissues was subjected to PCR with fungi universal primers 18S rDNA gene, and specific primers were designed based on the same gene in C. lamprauges that generated products of about 540 bp and 222 bp respectively. The culture was positive in 26.6% of clinical samples. The PCR technique for C. lamprauges showed amplification of DNA from fresh tissues (80%) and paraffin sections (44.4%). In conclusion, the PCR technique described here demonstrated a high sensitivity and specificity for detection of fungal DNA in tissue samples, providing a tool for the rapid diagnosis of C. lamprauges.
Resumo:
The main objective of the present study was to evaluate the diagnostic value (clinical application) of brain measures and cognitive function. Alzheimer and multiinfarct patients (N = 30) and normal subjects over the age of 50 (N = 40) were submitted to a medical, neurological and cognitive investigation. The cognitive tests applied were Mini-Mental, word span, digit span, logical memory, spatial recognition span, Boston naming test, praxis, and calculation tests. The brain ratios calculated were the ventricle-brain, bifrontal, bicaudate, third ventricle, and suprasellar cistern measures. These data were obtained from a brain computer tomography scan, and the cutoff values from receiver operating characteristic curves. We analyzed the diagnostic parameters provided by these ratios and compared them to those obtained by cognitive evaluation. The sensitivity and specificity of cognitive tests were higher than brain measures, although dementia patients presented higher ratios, showing poorer cognitive performances than normal individuals. Normal controls over the age of 70 presented higher measures than younger groups, but similar cognitive performance. We found diffuse losses of tissue from the central nervous system related to distribution of cerebrospinal fluid in dementia patients. The likelihood of case identification by functional impairment was higher than when changes of the structure of the central nervous system were used. Cognitive evaluation still seems to be the best method to screen individuals from the community, especially for developing countries, where the cost of brain imaging precludes its use for screening and initial assessment of dementia.
Resumo:
Pheochromocytomas are rare chromaffin cell tumors that nevertheless must be excluded in large numbers of patients who develop sustained or episodic hypertension as well as in many others with suggestive symptoms or with a familial history of pheochromocytoma. Diagnosis of pheochromocytoma depends importantly on biochemical evidence of excess catecholamine production by a tumor. Imperfect sensitivity and specificity of commonly available biochemical tests and the low incidence of the tumor among the tested population mean that considerable time and effort can be expended in confirming or ruling out pheochromocytoma in patients where the tumor is suspected. Measurements of plasma free metanephrines provide a superior test compared to other available tests for diagnosis of pheochromocytoma. In particular, the high sensitivity of plasma free metanephrines means that a normal test result reliably excludes all but the smallest of pheochromocytomas so that no other tests are necessary. Measurements of plasma free metanephrines, when systematically combined with other diagnostic procedures outlined in this review, provide a more efficient, reliable and cost-effective approach for diagnosis of pheochromocytoma than offered by previously available approaches.
Resumo:
Salivary cortisol is an index of plasma free cortisol and is obtained by a noninvasive procedure. We have been using salivary cortisol as a tool for physiological and diagnostic studies, among them the emergence of circadian rhythm in preterm and term infants. The salivary cortisol circadian rhythm in term and premature infants was established between 8 and 12 postnatal weeks. In the preterm infants the emergence of circadian rhythm was parallel to the onset of sleep rhythm. We also studied the use of salivary cortisol for screening for Cushing's syndrome (CS) in control and obese outpatients based on circadian rhythm and the overnight 1 mg dexamethasone (DEX) suppression test. Salivary cortisol was suppressed to less than 100 ng/dl after 1 mg DEX in control and obese patients. A single salivary cortisol measurement at 23:00 h and again after 1 mg DEX above the 90th percentile of the obese group values had sensitivity and specificity of 93 and 93% (23:00 h), and 91 and 94% (after DEX), respectively. The sensitivity improved to 100% when we combined both parameters. We also studied 11 CS children and 21 age-matched primary obese children for whom salivary cortisol sensitivity and specificity were 100/95% (23:00 h), and 100/95% (1 mg DEX), respectively. Similar to adults, sensitivity and specificity of 100% were obtained by combining 23:00 h and 1 mg DEX. The measurement of salivary cortisol is a useful tool for physiological studies and for the diagnosis of CS in children and adults on an outpatient basis.
Resumo:
To identify early metabolic abnormalities in type 2 diabetes mellitus, we measured insulin secretion, sensitivity to insulin, and hepatic insulin extraction in 48 healthy normal glucose-tolerant Brazilians, first-degree relatives of type 2 diabetic patients (FH+). Each individual was matched for sex, age, weight, and body fat distribution with a person without history of type 2 diabetes (FH-). Both groups were submitted to a hyperglycemic clamp procedure (180 mg/dl). Insulin release was evaluated in its two phases. The first was calculated as the sum of plasma insulin at 2.5, 5.0, 7.5, and 10.0 min after the beginning of glucose infusion, and the second as the mean plasma insulin level in the third hour of the clamp procedure. Insulin sensitivity index (ISI) was the mean glucose infusion rate in the third hour of the clamp experiment divided by the mean plasma insulin concentration during the same period of time. Hepatic insulin extraction was determined under fasting conditions and in the third hour of the clamp procedure as the ratio between C-peptide and plasma insulin levels. FH+ individuals did not differ from FH- individuals in terms of the following parameters [median (range)]: a) first-phase insulin secretion, 174 (116-221) vs 207 (108-277) µU/ml, b) second-phase insulin secretion, 64 (41-86) vs 53 (37-83) µU/ml, and c) ISI, 14.8 (9.0-20.8) vs 16.8 (9.0-27.0) mg kg-1 min-1/µU ml-1. Hepatic insulin extraction in FH+ subjects was similar to that of FH- ones at basal conditions (median, 0.27 vs 0.27 ng/µU) and during glucose infusion (0.15 vs 0.15 ng/µU). Normal glucose-tolerant Brazilian FH+ individuals well-matched with FH- ones did not show defects of insulin secretion, insulin sensitivity, or hepatic insulin extraction as tested by hyperglycemic clamp procedures.
Resumo:
Laminin levels in ascitic fluid have been proposed as a marker for neoplastic ascites. We compared the concentration of laminin in serum and in ascitic fluid from patients with hepatic cirrhosis and peritoneal carcinomatosis and assessed the diagnostic value of serum laminin levels in differentiating neoplastic from benign ascites. Laminin concentrations were determined by ELISA with antibodies against laminin extracted from the human placenta, in patients with ascites due to peritoneal carcinomatosis (N = 20) and hepatic cirrhosis (N = 33). Patients with infected or hemorrhagic ascites were excluded. The receiver operating characteristic curve was used to determine the sensitivity and specificity of serum laminin for the diagnosis of neoplastic ascites. When compared to the group with cirrhosis, the carcinomatosis group presented significantly higher mean laminin levels in serum (3.3 ± 0.5 vs 2.1 ± 0.4 µg/ml, mean ± SD, P < 0.05) and ascites (2.8 ± 0.5 vs 1.6 ± 0.4 µg/ml, P < 0.05). Although laminin concentration was higher in serum than in ascites, the laminin serum/ascites ratio and serum-ascites gradient did not differ between the studied groups. A significant correlation (r = 0.93, P < 0.0001) was observed between the serum and ascites laminin values. Serum laminin levels >2.25 µg/ml showed 100% sensitivity and 73% specificity for the diagnosis of neoplastic ascites. Serum concentration seems to be the main determinant of laminin levels in ascitic fluid and its values can be used as a diagnostic parameter in the study of neoplastic ascites.
Resumo:
We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.
Resumo:
Whole blood samples (N = 295) were obtained from different locations in Amazonas and Sucre States, in Venezuela. Malaria was diagnosed by microscopy, OptiMAL™ and polymerase chain reaction (PCR), with Plasmodium vivax, P. falciparum, and P. malariae being detected when possible. We identified 93 infections, 66 of which were caused by P. vivax, 26 by P. falciparum, and 1 was a mixed infection. No infection caused by P. malariae was detected. The sensitivity and specificity of each diagnostic method were high: 95.7 and 97.9% for microscopy, 87.0 and 97.9% for OptiMAL, and 98.0 and 100% for PCR, respectively. Most samples (72.2%) showed more than 5000 parasites/µL blood. The sensitivity of the diagnosis by microscopy and OptiMAL decreased with lower parasitemia. All samples showing disagreement among the methods were reevaluated, but the first result was used for the calculations. Parasites were detected in the 6 false-negative samples by microscopy after the second examination. The mixed infection was only detected by PCR, while the other methods diagnosed it as P. falciparum (microscopy) or P. vivax (OptiMAL) infection. Most of the false results obtained with the OptiMAL strip were related to the P. falciparum-specific band, including 3 species misdiagnoses, which could be related to the test itself or to genetic variation of the Venezuelan strains. The use of the microscopic method for malaria detection is recommended for its low cost but is very difficult to implement in large scale, population-based studies; thus, we report here more efficient methods suitable for this purpose.
Resumo:
Dietary fat composition can interfere in the development of obesity due to the specific roles of some fatty acids that have different metabolic activities, which can alter both fat oxidation and deposition rates, resulting in changes in body weight and/or composition. High-fat diets in general are associated with hyperphagia, but the type of dietary fat seems to be more important since saturated fats are linked to a positive fat balance and omental adipose tissue accumulation when compared to other types of fat, while polyunsaturated fats, omega-3 and omega-6, seem to increase energy expenditure and decrease energy intake by specific mechanisms involving hormone-sensitive lipase, activation of peroxisome proliferator-activated receptor α (PPARα) and others. Saturated fat intake can also impair insulin sensitivity compared to omega-3 fat, which has the opposite effect due to alterations in cell membranes. Obesity is also associated with impaired mitochondrial function. Fat excess favors the production of malonyl-CoA, which reduces GLUT4 efficiency. The tricarboxylic acid cycle and beta-oxidation are temporarily uncoupled, forming metabolite byproducts that augment reactive oxygen species production. Exercise can restore mitochondrial function and insulin sensitivity, which may be crucial for a better prognosis in treating or preventing obesity.
Resumo:
Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.
Resumo:
The diagnostic usefulness of Ziehl-Neelsen (ZN)-stained sputum smears combined with conventional polymerase chain reaction (ZN/PCR) to amplify IS6110 region DNA extracted from ZN slides was evaluated. The objective was to verify if this association could improve tuberculosis (TB) diagnosis in patients at remote sites. The study was carried out in 89 patients with culture-confirmed pulmonary TB as defined by the Brazilian Manual for TB Treatment. The participants were recruited in a reference unit for TB treatment in Rondônia, a state in the Amazonian area in northern Brazil. ZN, PCR, and culture performed in the sputum samples from these patients were analyzed in different combinations (i.e., ZN plus PCR and ZN plus culture). The prevalence rates of pulmonary TB in these patients were 32.6 and 28.1% considering culture and ZN/PCR, respectively. The sensitivity and specificity of ZN/PCR were 86 and 93%, respectively. ZN/PCR was able to detect more TB cases than ZN alone. This method could offer a new approach for accurate tuberculosis diagnosis, especially in remote regions of the world where culture is not available.
Resumo:
OBJECTIVE: To assess the usefulness of corneal esthesiometry for screening diabetic retinopathy. METHODS: A cross-sectional study was carried out comprising 575 patients attending a diabetic retinopathy-screening program in the city of São Paulo. Corneal esthesiometry was assessed with the Cochet-Bonnet esthesiometer. The presence of diabetic retinopathy was detected with indirect fundoscopy. The validity of corneal esthesiometry in identifying diabetic retinopathy was evaluated by the Receiver Operating Characteristic (ROC) curve. RESULTS: Sensitivity and specificity analyses of the corneal esthesiometry for detecting the stages of diabetic retinopathy using different cut-offs showed values less than 80%. The best indices (72.2% sensitivity and 57.4% specificity) were obtained for the identification of patients with proliferative diabetic retinopathy. CONCLUSIONS: In the study series, corneal esthesiometry was not a good indicator of diabetic retinopathy.
Resumo:
OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.
Resumo:
OBJECTIVE: To estimate the validity of three single questions used to assess self-reported hearing loss as compared to pure-tone audiometry in an adult population. METHODS: A validity study was performed with a random sub-sample of 188 subjects aged 30 to 65 years, drawn from the fourth wave of a population-based cohort study carried out in Salvador, Northeastern Brazil. Data were collected in household visits using questionnaires. Three questions were used to separately assess self-reported hearing loss: Q1, "Do you feel you have a hearing loss?"; Q2, "In general, would you say your hearing is 'excellent,' 'very good,' 'good,' 'fair,' 'poor'?"; Q3, "Currently, do you think you can hear 'the same as before', 'less than before only in the right ear', 'less than before only in the left ear', 'less than before in both ears'?". Measures of accuracy were estimated through seven measures including Youden index. Responses to each question were compared to the results of pure-tone audiometry to estimate accuracy measures. RESULTS: The estimated sensitivity and specificity were 79.6%, 77.4% for Q1; 66.9%, 85.1% for Q2; and 81.5%, 76.4% for Q3, respectively. The Youden index ranged from 51.9% (Q2) to 57.0% (Q1) and 57.9% (Q3). CONCLUSIONS: Each of all three questions provides responses accurate enough to support their use to assess self-reported hearing loss in epidemiological studies with adult populations when pure-tone audiometry is not feasible.