81 resultados para Selected-ion monitoring (SIM)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of substitute groups in biomonitoring programs has been proposed to minimize the high financial costs and time for samples processing. The objectives of this study were to evaluate the correlation between (i) the spatial distribution among the major zooplankton groups (cladocerans, copepods, rotifers, and testaceans protozoa), (ii) the data of density and presence/absence of species, and (iii) the data of species, genera, and families from samples collected in the Lago Grande do Curuai, Pará, Brazil. A total of 55 sample of the zooplanktonic community was collected, with 28 samples obtained in March and 27 in September, 2013. The agreement between the different sets of data was assessed using Mantel and Procrustes tests. Our results indicated high correlations between genus level and species level and high correlations between presence/absence of species and abundance, regardless of the seasonal period. These results suggest that zooplankton community could be incorporated in a long-term monitoring program at relatively low financial and time costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A double-blind, placebo-controlled multicenter study involving 34 centers from different Brazilian regions was performed to evaluate the antihypertensive efficacy and tolerability of trandolapril, an angiotensin I converting enzyme inhibitor, in the treatment of mild-to-moderate systemic arterial hypertension. METHODS: Of 262 patients enrolled in this study, 127 were treated with trandolapril 2 mg/day for 8 consecutive weeks, and the remaining 135 patients received placebo for the same period of time. Reduction in blood pressure (BP) and the occurrence of adverse events during this period were evaluated in both groups. RESULTS: Significant reductions in both systolic and diastolic pressures were observed in patients treated with trandolapril when compared with those on placebo. Antihypertensive efficacy was achieved in 57.5% of the patients on trandolapril and in 42% of these normal values of BP were obtained. The efficacy of trandolapril was similar in all centers, regardless of the area of the country. In a subset of 30 patients who underwent ABPM, responders showed a significant hypotensive effect to trandolapril throughout the 24 hour day. The adverse event profile was similar in both trandolapril and placebo groups. CONCLUSION: Our results demonstrate, for the first time in a large group of hypertensive patients from different regions in Brazil, good efficacy and tolerability of trandolapril during treatment of mild-to-moderate essential systemic hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP). METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI), systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI), and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2) and consumption (VO2), p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS). Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP) monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours) and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years). The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation) The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p<0.05); 2) pressure loads during wakefulness including the siesta, were less than those observed without the siesta); 3) the averages of nocturnal sleep blood pressures were similar to those of the siesta, 4) nocturnal sleep pressure drops were similar to those in the siesta including wakefulness with and without the siesta; 5) the averages of BP in men were higher (p<0.05) during wakefulness with and without the siesta, during the siesta and nocturnal sleep in relation to the average obtained in women; 6) patients with a reduction of 0- 5% during the siesta had thickening of the interventricular septum and a larger posterior wall than those with a reduction during the siesta >5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34) years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and <200µg/min in at least 2 out of 3 urine samples. RESULTS: Nine (24.3%) patients were microalbuminuric. Ambulatory blood pressure monitoring in the microalbuminuric patients had higher mean pressure values, mainly the systolic pressure, during sleep as compared with that in the normoalbuminuric patients (120.1±8.3 vs 110.8±7.1 mmHg; p=0.007). The pressure load was higher in the microalbuminuric individuals, mainly the systolic pressure load during wakefulness [6.3 (2.9-45.9) vs 1.6 (0-16%); p=0.001]. This was the variable that better correlated with the urinary excretion of albumin (rS=0.61; p<0.001). Systolic pressure load >50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008). The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare sleepiness scores of the Epworth scale in patients with different levels of arterial pressure when undergoing outpatient monitoring within the context of clinical evaluation. METHODS: A total of 157 patients selected for outpatient monitoring of arterial pressure during hypertension evaluation were divided into 3 groups: group 1 - normotensive; group 2 - hypertensive; group 3 - resistant hypertensive. For analysis, values > or = 11 were considered as associated with respiratory disturbances during sleep. RESULTS: Seventeen (10.8%) patients in group 1, 112 (71.3%) in group 2, and 28 (17.8%) in group 3, which was composed of aged, more severely hypertensive individuals, were analyzed. Groups were similar relative to sex and body mass index, but different in relation to systolic and diastolic pressure levels and age. Despite an absolute difference, no statistically significant difference occurred between Epworth scores and in the proportion of patients with values > or = 11 (5.9% vs. 18.8% vs. 212.4%; P=0.37). Despite the positive association between degree of sleepiness measured with the scale and the severity of the hypertension, no statistical significance occurred following control by age (p=0.18). CONCLUSION: A positive correlation exists between degree of sleepiness and hypertension severity. The absence of a statistical significance shown in the present study could be due to a beta type of error. Instruments that render this complaint into an objective finding could help in the pursuit of an investigation of respiratory disturbances during sleep in more severely hypertensive patients, and should therefore be studied better.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring. METHODS: We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall during sleep associated with a specific questionnaire and an analogical visual scale of tolerance for ambulatory blood pressure monitoring were used to assess usual sleep and sleep on the day of examination. Two specialists in sleep disturbances classified the patients into 2 groups: those with normal sleep and those with abnormal sleep. RESULTS: Fifty-nine (35 %) patients comprised the abnormal sleep group. Findings regarding the quality of sleep on the day of ambulatory blood pressure monitoring as compared with those regarding the quality of sleep on a usual day were different and were as follows, respectively: total duration of sleep (-12.4±4.7 versus -42.2±14.9 minutes, P=0.02), latency of sleep (0.4±2.7 versus 17±5.1 minutes, P<0.001), number of awakenings (0.1±0.1 versus 1.35±0.3 times, P<0.001), and tolerance for ambulatory blood pressure monitoring (8±0.2 versus 6.7±0.35, P=0.035). An abnormal drop in blood pressure during sleep occurred in 20 (18%) patients in the normal sleep group and in 14 (24%) patients in the abnormal sleep group, P=0.53. CONCLUSION: Ambulatory blood pressure monitoring causes sleep disturbances in some patients, and a positive association between quality of sleep and tolerance for the examination was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The specific activities of acid phosphatase, alkaline phosphatase, β-glucuronidase, lysozymes, glutamate-oxalacetate transaminase and glutamate-pyruvate transaminate were determined in the head-foot and digestive gland of Brazilian Biomphalaria glabrata (Touros), B. tenagophila (Caçapava) and B. straminea (Monsenhor Gil). All six enzymes were detected inthe 3000g supernatant. Both cytoplasmic enzymes, glutamate-oxalacetate and glutamate-pyruvate transaminase exhibited the highest specific activities. In the case of the four hydrolytic enzymes assayed, β-glucuronidase exhibited the highest specific activity while lysozyme showed the lowest activity. All six enzymes are thought to be produced by cells within the head-foot and digestive gland of B. glabrata, B. tenagophila and B. straminea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular karyotypes for 20 reference strais of species complexes of Leishmania were determined by contour-clamped homogeneous eletric field (CHEF) electrosphoresis. Determination of number/position of chromosome-sized bands and chromosomal DNA locations of house-keeping genes were the two criteria used for differentiating and classifying the Leishmania species. We have established two gel running conditions of optimal separation of chromosomes, wich resolved DNA molecules as large as 2,500 kilobase pairs (kb). Chromosomes were polymorphic in number (22-30) and size (200-2,500 kb) of bands among members of five complexes of Leishmania. Although each stock had a distinct karyotype, in general the differences found between strains and/or species within each complex were not clear enough for parasite identification. However, each group showed a specific number of size-concordant DNA molecules, wich allowed distinction among the Leishmania complex parasites. Clear differences between the Old and New world groups of parasites or among some New World Leishmania species were also apparent in relation to the chromosome locations of beta-tubulin genes. Based on these results as well as data from other published studies the potencial of using DNA karyotype for identifying and classifying leishmanial field isolates is discussed.