53 resultados para Research assessment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-intensity lasers are used for prevention and management of oral mucositis induced by anticancer therapy, but the effectiveness of treatment depends on the genetic characteristics of affected cells. This study evaluated the survival and induction of filamentation of Escherichia coli cells deficient in the nucleotide excision repair pathway, and the action of T4endonuclease V on plasmid DNA exposed to low-intensity red and near-infrared laser light. Cultures of wild-type (strain AB1157) E. coli and strain AB1886 (deficient in uvrA protein) were exposed to red (660 nm) and infrared (808 nm) lasers at various fluences, powers and emission modes to study bacterial survival and filamentation. Also, plasmid DNA was exposed to laser light to study DNA lesions produced in vitro by T4endonuclease V. Low-intensity lasers:i) had no effect on survival of wild-type E. coli but decreased the survival of uvrA protein-deficient cells,ii) induced bacterial filamentation, iii) did not alter the electrophoretic profile of plasmids in agarose gels, andiv) did not alter the electrophoretic profile of plasmids incubated with T4 endonuclease V. These results increase our understanding of the effects of laser light on cells with various genetic characteristics, such as xeroderma pigmentosum cells deficient in nucleotide excision pathway activity in patients with mucositis treated by low-intensity lasers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reviewed the use of the Strengths and Weaknesses of Attention-Deficit/Hyperactivity-symptoms and Normal-behaviors (SWAN) rating scale in diagnostic and evolutive approaches to attention deficit hyperactivity disorder (ADHD) and in correlational studies of the disorder. A review of articles published in indexed journals from electronic databases was conducted and 61 articles on the SWAN scale were analyzed. From these, 27 were selected to a) examine use of SWAN in research on attention disorders and b) verify evidence of its usefulness in the areas of genetics, neuropsychology, diagnostics, psychiatric comorbidities, neuroimaging, pharmacotherapy, and to examine its statistical reliability and validity in studies of diverse populations. This review of articles indicated a growing use of the SWAN scale for diagnostic purposes, for therapy, and in research on areas other than ADHD, especially when compared with other reliable scales. Use of the scale in ADHD diagnosis requires further statistical testing to define its psychometric properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Subjects with chronic liver disease are susceptible to hypovitaminosis A due to several factors. Therefore, identifying patients with vitamin deficiency and a requirement for vitamin supplementation is important. Most studies assessing vitamin A in the context of hepatic disorders are conducted using cirrhotic patients. A cross-sectional study was conducted in 43 non-cirrhotic patients with chronic hepatitis C to evaluate markers of vitamin A status represented by serum retinol, liver retinol, and serum retinol-binding protein levels. We also performed the relative dose-response test, which provides an indirect estimate of hepatic vitamin A reserves. These vitamin A indicators were assessed according to the stage of liver fibrosis using the METAVIR score and the body mass index. The sample study was predominantly composed of male subjects (63%) with mild liver fibrosis (F1). The relative dose-response test was <20% in all subjects, indicating vitamin A sufficiency. Overweight or obese patients had higher serum retinol levels than those with a normal body mass index (2.6 and 1.9 µmol/L, respectively; P<0.01). Subjects with moderate liver fibrosis (F2) showed lower levels of serum retinol (1.9 vs 2.5 µmol/L, P=0.01) and retinol-binding protein levels compared with those with mild fibrosis (F1) (46.3 vs 67.7 µg/mL, P<0.01). These results suggested an effect of being overweight on serum retinol levels. Furthermore, more advanced stages of liver fibrosis were related to a decrease in serum vitamin A levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the diagnostic value of the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) of magnetic resonance diffusion tensor imaging (DTI) in patients with spinal cord compression (SCC) using a meta-analysis framework. Multiple scientific literature databases were exhaustively searched to identify articles relevant to this study. Mean values and standardized mean differences (SMDs) were calculated for the ADC and FA in normal and diseased tissues. The STATA version 12.0 software was used for statistical analysis. Of the 41 articles initially retrieved through database searches, 11 case-control studies were eligible for the meta-analysis and contained a combined total of 645 human subjects (394 patients with SCC and 251 healthy controls). All 11 studies reported data on FA, and 9 contained data related to the ADC. The combined SMDs of the ADC and FA showed that the ADC was significantly higher and the FA was lower in patients with SCC than in healthy controls. Subgroup analysis based on the b value showed higher ADCs in patients with SCC than in healthy controls at b values of both ≤500 and >500 s/mm2. In summary, the main findings of this meta-analysis revealed an increased ADC and decreased FA in patients with SCC, indicating that DTI is an important diagnostic imaging tool to assess patients suspected to have SCC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessing fish consumption is complex and involves several factors; however, the use of questionnaires in surveys and the use of the Internet as tool to collect data have been considered promising approaches. Therefore, the objective of this research was to design a data collection technique using a questionnaire to assess fish consumption by making it available on a specific home page on the Internet. A bibliographical survey or review was carried out to identify the features of the instrument, and therefore pre-tests were conducted with previous instruments, followed by the Focus Group technique. Specialists then performed an analysis and conducted an online pre-test. Multivariate data analysis was applied using the SmartPLS software. The results indicate that 1.966 participants belonging to the University of São Paulo (USP) community participated in the test, and after the exclusion of some variables, a statistically significant results were obtained. The final constructs comprised consumption, quality, and general characteristics. The instrument consisted of behavioral statements in a 5-point Likert scale and multiple-choice questions. The Cronbach's alpha reliability coefficient was 0.66 for general characteristics, 0.98 for quality, and 0.91 for consumption, which indicate good reliability of the instrument. In conclusion, the results proved that the Internet assessment is efficient. The instrument of analysis allowed us to better understand the process of buying and consuming fish in the country, and it can be used as base for further research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.