476 resultados para Química analítica-Manuales


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Considered the best substitute for diesel, biodiesel can be blended with diesel in any ratio, bringing lots of environmental, economic and social advantages. Brazilian law Nº 11097/2005, proposes the introduction of biodiesel in to the Brazilian energy matrix, mixed with diesel at a minimum percentage of 2%. For consumers and sellers to be sure that the commercialized mixture of biodiesel:diesel contains the correct percentage, it is necessary to develop analytical methodologies to quantify the amount of biodiesel added. This work presents a fast, low-cost and simple methodology to determine the biodiesel proportion in mixtures of biodiesel:diesel, based on infrared spectroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A chromatographic method was developed for cholesterol determination in feed for ruminants using response surface methodology. Among the five approaches of sample preparation methods tested, the saponification of the sample without heating presented less interference in the gas chromatography. The method presented a relative standard deviation (RSD) of 4.3%, recoveries between 84 and 87% and detection limit of 0.001 mg of cholesterol per g of feed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper historical aspects of analytical pyrolysis, the equipment used, the fundamentals and the mechanisms of pyrolysis of different polymeric materials are discussed. The latest work on analytical pyrolysis applied to various types of synthetic and natural samples is reviewed. Current applications of this technique that are discussed include identification of microorganisms, analysis of trace compounds by forensic laboratories, investigation of food and agricultural products, study of the chemical composition of wood, authentication and conservation of artworks, and the study of environmental and geochemical samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bupivacaine (S75-R25, NovaBupi®) is an amide type local anesthetic widely used. The present work consists of the development and validation of analytical methodology for evaluation of NovaBupi® content in the poly-lactide-co-glycolide nanospheres (PLGA-NS) by high performance liquid chromatography. The separation was made using the reversed-phase column LC-18, acetonitrile/phosphate buffer 85:15 v/v as mobile phase and detection at 220 nm. The results obtained show that the analytical methodology is accurate, reproducible, robust and linear over the concentration range 10-220.0 g/mL of NovaBupi®. The method was applied to determine the encapsulation efficiency and evaluate the release profile of NovaBupi®, showing good results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an experiment to teach the principles of gas chromatography exploring the boiling points and polarities to explain the elution order of a series of alcohols, benzene and n-propanone, as well as to teach the response factor concept and the internal standard addition method. Retention times and response factors are used for qualitative identification and quantitative analysis of a hypothetical contamination source in a simulated water sample. The internal standard n-propanol is further used for quantification of benzene and n-butanol in the water sample. This experiment has been taught in the instrumental analysis course offered to chemistry and oceanography students.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to develop and validate an analytical methodology for determination of artemisinin used as antimalaric. The method was based on high performace liquid chromatography, using a CN column with mobile phase composed of methanol : H2O 50:50 (V/V). The results showed that the method presented linearity from 50 to 1500 µg/mL. It was considered selective, accurate, precise according to the specific resolution from ANVISA, the Brazilian regulatory agency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study examined the optimization of stabilization and extraction processes of the flavonoids of Bauhinia cheilantha (Bongard) Steudel. Four drying temperatures (room temperature, 40, 60 and 80 ºC) and seven extraction systems (distilled water, 100% methanol, 80% methanol, 100% ethanol, 80% ethanol, 80% acetone and 60% acetone) were examined. The results demonstrated a reduction in flavonoid levels with increasing drying temperatures; and 80% acetone, 80% ethanol, and methanol p.a extraction systems were found to be most efficient and its weren't differents statisticaly (p<0.05).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the development of an easy, fast and effective procedure for the verification of the ideal gas law in splitless injection systems in order to improve the response. Results of a group of pesticides were used to demonstrate the suitability of the approach. The procedure helps establish experimental parameters through theoretical aspects. The improved instrumental response allowed extraction with lower sample volumes, the minimization of time and costs and the simplification of sample preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metabolic reactive intermediates can react with biomolecules such as DNA and proteins to produce adducts. Recently, research has shown that such adducts can act as precursors of some chronic diseases (cancer, Parkinson's, immunologic system diseases, etc.), and their determination is important because they are biomarkers of undesirable health effects. These compounds are produced at very low concentrations, but the development and dissemination of sensitive new analytical tools, especially those based on chromatography coupled to other analytical instruments, make such determinations possible. This mini review is focused on the formation of reactive intermediates, their reaction with biomolecules, and the importance of their determination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Propõe-se metodologia analítica para a determinação da demanda química de oxigênio(DQO) em águas e efluentes pouco poluídos, pela espectrofotometria simultânea dos íons crômio(III) e dicromato, após a clássica oxidação sulfocrômica das amostras, à quente e catalisada por íons Ag+. Demonstra-se que a inter-relação entre as concentrações de DQO, de crômio(III) formado e de dicromato residual permite simplificar a resolução numérica do sistema - de multicomponente, envolvendo as concentrações desses dois íons, e medidas de absorbância em pelo menos dois comprimentos de onda para monocomponente, envolvendo diretamente a concentração em DQO, e medida de absorbância num único comprimento de onda.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Observando a literatura pode ser verificado um crescente número de trabalhos que determinam potenciais contaminantes presentes em matrizes de interesse ambiental. É importante ressaltar que quando se estuda o ambiente, os dados analíticos são uma das ferramentas usadas para se avaliar a extensão dos problemas observados que conseqüentemente influenciam as tomadas de decisão. Assim a confiabilidade desses dados é de extrema importância. Neste contexto, este trabalho visa avaliar a confiabilidade analítica das determinações de Carbono Orgânico Total (COT), ferramenta empregada no monitoramento da matéria orgânica em diversos estudos ambientais. Para essa avaliação foram analisados alguns parâmetros de desempenho como limite de detecção e quantificação, repetibilidade e linearidade.