71 resultados para PH3 flow rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Silica gel chemically modified with 2-Aminotiazole groups, abbreviated as SiAT, was used for preconcentration of copper, zinc, nickel and iron from kerosene, normally used as a engine fuel for airplanes. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl- 0.25-2.00 mol L-1) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for copper, iron, nickel and zinc are 0.77, 2.92, 1.73 and 0.097 mg L-1, respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in kerosene using flame AAS for their quantification.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensor coated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect of temperature, flow rate, and some possible interferents were carried out. Calibration curves, sensor stability (lifetime) and the precision of measurements were also verified. The resulting selectivity is probably due to the coordinative binding between the electronically unsatured metal complexes and the analyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Plug dynamics of non compensate drip tubes were evaluated, by the precipitation of moisturized whitewash [Ca(OH)2], which is used in the fertigation for the bulb pH control of the trademarks Azud, Amanco, Naandan, Netafim, Petroisa, Queen Gil, with flow rate varying between 0.4 to 3.0 L h-1 usually used in the country. For this matter, increasing doses of Ca(OH)² were applied in the irrigation water, from 0.01 g L-1 to 1.84 g L-1. The flow rate of each drip tube was measured in intervals of time initially of 7 days, later of 15 days of system operation, totaling a time of 100 days of operation, corresponding to nine applications or 432 hours. The coefficient of variation (CV), and relative rate flow (Qr) were evaluated. The results pointed differences among the evaluated emitter regarding the occurrence of the clogging, and the models G2 and G5 presented the smallest levels of flow rate variation comparing to the models G6, G7 and G9.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to characterize water application rate, water application pattern width, flow rate, water distribution uniformity and soil loss caused by nozzles of the Low Energy Precision Aplication (LEPA) type Quad-Spray emitter. The study was carried out at the Hydraulic and Irrigation Laboratory of the Department of Engineering at the Federal University of Lavras, in Lavras, state of Minas Gerais - MG, Brazil. Twenty-two (22) LEPA Quad-Spray emitter nozzles were evaluated, with nozzle diameter ranging from 1.59 to 9.92 mm. The experimental design used was entirely randomized, with three replications.Increasing values of nozzle flow rate ranging from 77.44 up to 3,044 L h-1, were obtained with increasing nozzle diameter sizes. Application pattern width ranged from 0.56 up to 3.24m, according to nozzles diameter size. Low values of CDU (maximum of 35.73%) were observed when using the Quad-Spray nozzles. Observed average water application rates covered the range between 68.05 mm h-1 (the lowest value that was obtained with the 2.38mm nozzle) and 258.15 mm h-1 (the highest value that was observed with the 9.92 mm). Average water application rates increased in a simple non-linear function with the increase of nozzle size diameter. However, the weighted average increase in the amount of soil loss by erosion was not related to the increase of weighted average water application values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To optimize the use of pesticides, several countries have carried out periodic inspections in agricultural sprayers. In Brazil, knowing the conditions of this machinery canguide researches and investments in guidelines for its use and maintenance. The objective of this study was to verify the state of sprayer maintenance used in the North of the state of Paraná, in Brazil. Several sprayer items were evaluated, such as: presence, status and scale of the manometer, status of the hose, status of the anti-drip component, presence of leaks, status of the bar, status of the filters, state of the spraying nozzles and errors in the targeted flow rate. Machines were named as approved when there was no failure in any item evaluated. The factor that caused the biggest level of reprove among the machines was incorrect scale of manometers, which reproved 84.55% of the machines evaluated. Other outstanding factor was the incorrect flow rate in 75.5% of the tested machines. Only one unit was approved from the total of 110 evaluated sprayers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to evaluate growth and yield of papaya cv. Sunrise solo under trickle irrigation system configurations. A random block design was used with six treatments and four replications. Treatments were: T1- a 32 L h-1 micro sprinkler; T2 - a 43 L h-1 micro sprinkler and T3 - a 60 L h-1 micro sprinkler for four plants; T4 - Drip system with four emitters per plant on one lateral line per crop row; T5 - Drip system with eight emitters per plant on two laterals line per crop row; T6 - Drip system with four emitters per plant on one lateral line distributed as pig tail. The dripper flow rate was 4 L h-1and they were apart each other 0.50 m. Crop growth variables were measured every two weeks. Production variables were evaluated during harvest. The treatment that presented superiority was irrigated by micro sprinkler system with flow rate of 43 L h-1.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficiency of a sequencing batch reactor (SBR) on biological removal of nitrogen from cattle slaughterhouse wastewater by nitrification/denitrification processes. The effects of initial concentration of ammoniacal nitrogen were investigated at 100; 150 and 200 mg L-1 and air flow rate at 0.125; 0.375 and 0.625 L min¹ Lreactor-1 on the nitrogen compounds removal, by a Central Composite Rotational Design (CCRD) configuration. There were variations from 9.2 to 94.9%, 4.0 to 19.6% and 20.8 to 92.0% in the conversion of ammoniacal nitrogen to nitrate and nitrite concentration and removal of total nitrogen, respectively. The increase of air flow rate and decrease of the initial concentration of ammoniacal nitrogen resulted in higher efficiencies of total nitrogen removal, as well as the conversion of ammoniacal nitrogen to nitrate. During the pre-established intervals of this study, the removal and conversion efficiencies of nitrogen compounds above 85% were achieved in air flow rate variations from 0.375 to 0.725 L min-1 Lreactor-1 and initial concentration of ammoniacal nitrogen from 80 to 200 mg L-1. On denitrification process, we obtained efficiencies from 91.5 to 96.9% on the removal of nitrite/nitrate and from 78.3 to 87.9% on the removal of organic matter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To identify the predictive factors for voiding dysfunction after transobturator slings. METHODS: We retrospectively reviewed the records of all patients who underwent a transobturator sling between March 2003 and December 2008. A total of 514 women had available data with at least a six-week follow-up. Patients' demographics, preoperative symptoms, urodynamic testing including multichannel voiding studies and surgical variables were tabulated. Voiding dysfunction was defined by a catheterized or ultrasonographic postvoid residual greater than 100 cc (≥six weeks after the procedure) associated with any complaints of abnormal voiding. Univariate logistic regression analysis was performed with respect to postoperative voiding dysfunction. RESULTS: The patient population had a mean age of 58.5±12.9 years. Thirty-three out of 514 patients (6.4%) had postoperative voiding dysfunction according to our definition, and 4 (0.78%) required sling transection. No differences were observed between normal and dysfunctional voiders in age, associated prolapse surgery, preoperative postvoid residual, preoperative urinary flow rate, prior pelvic surgery, and menopausal status. Valsalva efforts during the preoperative pressure flow study was the only predictive factor for postoperative voiding dysfunction, 72.4% dysfunctional versus 27.6% normal (p<0.001). CONCLUSION: Preoperative Valsalva maneuver during the micturition could identify those at risk for voiding dysfunction after transobturator sling, and it should be noted during preoperative counseling.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed using electrically heated rods to simulate operational and accidental conditions of nuclear fuel rods. In the present work, it is performed a theoretical analysis of the drying and rewetting front propagation during a critical heat flux experiment, starting with the application of an electrical power step from steady state condition. After the occurrence of critical heat flux, the drying front propagation is predicted. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. Studies performed with various values of coolant mass flow rate show that this variable has more influence on the drying front velocity than on the rewetting one.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The flow of Bingham liquids through porous media has been studied. Experiments have been performed to determine the flow rate / pressure drop relationship for the flow of a grease of Binghamian rheological behavior through an array of rods of circular cross section. The yield stress and plastic viscosity of the grease have been determined with the aid of a controlled stress rotational rheometer. To investigate a wider range of the flow parameters, the mass and momentum conservation equations have been solved numerically, in conjunction with the generalized Newtonian constitutive law and the bi-viscosity model. The finite volume method has been employed to obtain the numerical solution. These numerical results also yielded a flow rate / pressure drop relationship, which is in very good agreement with the experimental results. A capillaric theory has been developed to determine an analytical relationship between the flow rate and pressure drop for flows of Bingham liquids through porous media. It is shown that the predictions of this theory are in good agreement with the experimental and numerical results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The severe bleeding diathesis produced by intoxication with the venom of Lonomia achelous caterpillars is characterized by prolonged bleeding from superficial skin wounds as well as massive hemorrhage into body cavities. The aim of the present study was to evaluate the effect of the crude venom and its fibrinolytic fractions on in vitro lysis of whole blood clots. Venom fractions with fibrinolytic activity were obtained by gel filtration chromatography on Sephadex G75 using imidazole buffer, pH 7.4, at a flow rate of 24 ml/h. Four peaks with fibrinolytic activity were obtained by this method. The highest activity was found in the first two peaks (both peaks were used for the experiments). The results show that the caterpillar venom degraded the preformed clots at a slower rate than plasmin. In addition, plasma protease inhibitors of the fibrinolytic system (a2-antiplasmin, a2-macroglobulin, PAI, etc.) only weakly inhibited the lytic effect of the caterpillar venom. These characteristics, as well as the pattern of fibrinogen degradation products, the delay period on fibrin plate lysis and amidolytic activity on chromogenic substrate, reported previously, indicate that the caterpillar enzymes are different from plasmin and trypsin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

R,S-sotalol, a ß-blocker drug with class III antiarrhythmic properties, is prescribed to patients with ventricular, atrial and supraventricular arrhythmias. A simple and sensitive method based on HPLC-fluorescence is described for the quantification of R,S-sotalol racemate in 500 µl of plasma. R,S-sotalol and its internal standard (atenolol) were eluted after 5.9 and 8.5 min, respectively, from a 4-micron C18 reverse-phase column using a mobile phase consisting of 80 mM KH2PO4, pH 4.6, and acetonitrile (95:5, v/v) at a flow rate of 0.5 ml/min with detection at lex = 235 nm and lem = 310 nm, respectively. This method, validated on the basis of R,S-sotalol measurements in spiked blank plasma, presented 20 ng/ml sensitivity, 20-10,000 ng/ml linearity, and 2.9 and 4.8% intra- and interassay precision, respectively. Plasma sotalol concentrations were determined by applying this method to investigate five high-risk patients with atrial fibrillation admitted to the Emergency Service of the Medical School Hospital, who received sotalol, 160 mg po, as loading dose. Blood samples were collected from a peripheral vein at zero, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 6.0, 8.0, 12.0 and 24.0 h after drug administration. A two-compartment open model was applied. Data obtained, expressed as mean, were: CMAX = 1230 ng/ml, TMAX = 1.8 h, AUCT = 10645 ng h-1 ml-1, Kab = 1.23 h-1, a = 0.95 h-1, ß = 0.09 h-1, t(1/2)ß = 7.8 h, ClT/F = 3.94 ml min-1 kg-1, and Vd/F = 2.53 l/kg. A good systemic availability and a fast absorption were obtained. Drug distribution was reduced to the same extent in terms of total body clearance when patients and healthy volunteers were compared, and consequently elimination half-life remained unchanged. Thus, the method described in the present study is useful for therapeutic drug monitoring purposes, pharmacokinetic investigation and pharmacokinetic-pharmacodynamic sotalol studies in patients with tachyarrhythmias.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study focused on the role of sympathetic renal nerve activity, in mediating congestive heart failure-induced sodium retention following experimental chronic myocardial infarction. Groups of male Wistar rats (240-260 g) were studied: sham-operated coronary ligation (CON3W, N = 11), coronary ligation and sham-operated renal denervation (INF3W, N = 19), 3 weeks of coronary ligation and sympathetic renal nerve denervation (INF3WDX, N = 6), sham-operated coronary ligation (N = 7), and 16 weeks of coronary ligation (INF16W, N = 7). An acute experimental protocol was used in which the volume overload (VO; 5% of body weight) was applied for 30 min after the equilibration period of continuous iv infusion of saline. Compared to control levels, VO produced an increase (P < 0.01, ANOVA) in urine flow rate (UFR; 570%) and urinary sodium excretion (USE; 1117%) in CON3W. VO induced a smaller increase (P < 0.01) in USE (684%) in INF3W. A similar response was also observed in INF16W. In INF3WDX, VO produced an immediate and large increase (P < 0.01) in UFR (547%) and USE (1211%). Similarly, in INF3W VO increased (P < 0.01) UFR (394%) and USE (894%). Compared with INF3W, VO induced a higher (P < 0.01) USE in INF3WDX, whose values were similar to those for CON3W. These results suggest that renal sympathetic activity may be involved in sodium retention induced by congestive heart failure. This premise is supported by the observation that in bilaterally renal denervated INF3WDX rats myocardial infarction was unable to reduce volume expansion-induced natriuresis. However, the mechanism involved in urinary volume regulation seems to be insensitive to the factors that alter natriuresis.