53 resultados para Manufacturing Performance
Resumo:
INTRODUCTION: Human cytomegalovirus (HCMV) is often reactive in latently infected immunosuppressed patients. Accordingly, HCMV remains one of the most common infections following solid organ and hemopoietic stem cell transplantations, resulting in significant morbidity, graft loss and occasional mortality. The early diagnosis of HCMV disease is important in immunosuppressed patients, since in these individuals, preemptive treatment is useful. The objective of this study was to compare the performance of the in-house qualitative polymerase chain reaction (PCR) and pp65 antigenemia to HCMV infection in immunosuppressed patients in the Hospital de Clínicas of Porto Alegre (HCPA). METHODS: A total of 216 blood samples collected between August 2006 and January 2007 were investigated. RESULTS: Among the samples analyzed, 81 (37.5%) were HCMV-positive by PCR, while 48 (22.2%) were positive for antigenemia. Considering antigenemia as the gold standard, sensitivity, specificity, positive predictive values and negative predictive values for PCR were 87.5%, 76.8%, 51.8% and 95.5% respectively. CONCLUSIONS: These results demonstrated that qualitative PCR has high sensitivity and negative predictive value (NPV). Consequently PCR is especially indicated for the initial diagnosis of HCMV infection. In the case of preemptive treatment strategy, identification of patients at high-risk for HCMV disease is fundamental and PCR can be useful tool.
Resumo:
Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).
Resumo:
Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.
Resumo:
Introduction This study evaluated the performance of an in-house nested-PCR system for the detection of the Mycobacterium tuberculosis complex in pleural fluid, blood and urine samples from pleural effusion tuberculosis patients by health services physicians in Pernambuco, Brazil. Methods A prospective double-blind study with 37 hospitalized patients of both sexes, aged over 15, was used to investigate the diagnosis of pleural effusion. The criteria used to define the cases included the demonstration of bacillus in biological samples by smear or culture or by a granulomatous finding in the histopathological examination, associated with an evident response to specific treatments to each clinical situation. Pleural fluid, blood and urine samples were collected and subjected to routine tests and the nested PCR technique to assess for M. tuberculosis amplification. Results In total, 37 pleural effusion patients took part in the study, of whom 19 (51.3%) had tubercular etiologies and 18 (48.7%) had etiologies from other causes. When the pleural fluid, blood and/or urine sample in-house nested-PCR sensitivities were evaluated simultaneously, the results were positive regardless of the biological specimen (the sensitivity was 84.2%); however, when the blood and/or urine samples were analyzed together, the sensitivity was 72.2%. When the pleural fluid samples were evaluated alone, the sensitivity was only 33.3%. Conclusions The performance of the diagnostic pleural tuberculosis nested-PCR was directly related to the diversity of the samples collected from the same patient. Additionally, this study may identify a need to prioritize non-invasive blood and urine collection for this diagnosis.
Resumo:
Introduction. The genera Enterococcus, Staphylococcus and Streptococcus are recognized as important Gram-positive human pathogens. The aim of this study was to evaluate the performance of Vitek 2 in identifying Gram-positive cocci and their antimicrobial susceptibilities. Methods. One hundred four isolates were analyzed to determine the accuracy of the automated system for identifying the bacteria and their susceptibility to oxacillin and vancomycin. Results. The system correctly identified 77.9% and 97.1% of the isolates at the species and genus levels, respectively. Additionally, 81.8% of the Vitek 2 results agreed with the known antimicrobial susceptibility profiles. Conclusion. Vitek 2 correctly identified the commonly isolated strains; however, the limitations of the method may lead to ambiguous findings.
Resumo:
ABSTRACT INTRODUCTION: Human metapneumovirus (hMPV) is an emergent human respiratory pathogen. This study aimed to evaluate the performance of direct immunofluorescence (DIF) to detect hMPV in a clinical laboratory setting. METHODS: Nasopharyngeal aspirate samples (448) of children and adults with respiratory illness were used to detect hMPV by using DIF and real time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assays. RESULTS: In all, 36 (8%) samples were positive by DIF and 94 (21%) were positive by qRT-PCR. Direct immunofluorescence specificity was 99% and sensitivity was 38%. CONCLUSIONS: DIF is not very sensitive under clinical laboratory settings.
Resumo:
INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
Resumo:
No estado do Tocantins, o cultivo de milho em "terras altas sob cerrado" apresenta níveis de produtividade variáveis, cuja média não ultrapassa 2 t/ha. Fatores de solo, como acidez, baixos teores de Ca, Mg, Ρ e Κ e matéria orgânica, concorrem para reduzir as produtividades. O desenvolvimento de materiais genéticos melhorados busca contribuir na superação dessas limitações. Como atividade inicial em um programa de melhoramento genético, o presente estudo avaliou um total de 160 populações de milho, nas safras 1994/95, 1995/96 e 1998/99, nos municípios de Pedro Afonso e Gurupi, em termos de produtividade de grãos (PG), altura da planta (AP), altura da espiga (AE) e dias para florescimento feminino (FF). Para PG, os efeitos de populações foram significativos em todas as avaliações, ocorrendo produtividades entre 1,59 t/ ha a 7,46 t/ha. Destacaram-se as populações IAPAR 51, EGO 17, CMS 08, CMS 50, COMPOSTO TERRAS BAIXAS, TAIÚBA, TAITINGA, CMS 28, CMS 15 e SIKALQ, em Pedro Afonso, e K9201, CMS 39, BR 105 e CMS 03, em Gurupi, com produtividades acima de 5 t/ha. As diferenças nas performances produtivas e agronômicas em Pedro Afonso e Gurupi, juntamente com efeitos significativos das interações populações χ locais, alertam para a condução de programas de melhoramento específicos para cada local.