117 resultados para Liquid chromatography-diode array detection
Resumo:
In order to obtain intravenous immunoglobulin G (iv IgG) of high quality from F-I+II+III or F-II+III pastes prepared by the Cohn method, we developed a chromatography process using ion exchange gels, Q-Sepharose FF and CM-Sepharose FF, and Sephacryl S-300 gel filtration. Viral inactivation was performed by incubating the preparation with pepsin at pH 4.0 at 35oC for 18 h. The characteristics of 28 batches produced by us were: yield 4.3 ± 0.2 g/l plasma, i.e., a recovery of 39.1 ± 1.8%; IgG subclasses distribution: IgG1 = 58.4%, IgG2 = 34.8%, IgG3 = 4.5% and IgG4 = 2.3%; IgG size distribution was 98.4% monomers, 1.2% dimers and 0.4% polymers and protein aggregates; anticomplement activity was less than 0.5 CH50/mg IgG, and prekallikrein activator activity (PKA) was less than 5 IU/ml. These characteristics satisfied the requirements of the European Pharmacopoea edition, and the regulations of the Brazilian Health Ministry (M.S. Portaria No. 2, 30/10/1998).
Resumo:
The aim of the method described here is to remove hemoglobin, the major contaminant in the bovine plasma obtained from slaughterhouses, by adding a mixture of 19% cold ethanol and 0.6% chloroform, followed by fibrinogen and globulin precipitation by the Cohn method and nonspecific hemagglutinin by thermocoagulation. The experimental volume of bovine plasma was 2,000 ml per batch. Final purification was performed by liquid chromatography using the ion-exchange gel DEAE-Sepharose FF. The bovine albumin thus obtained presented > or = 99% purity, a yield of 25.0 ± 1.2 g/l plasma and >71.5% recovery. N-acetyl-DL-tryptophan (0.04 mmol/g protein) and sodium caprylate (0.04 mmol/g protein) were used as stabilizers and the final concentration of albumin was adjusted to 22.0% (w/v), pH 7.2 to 7.3. Viral inactivation was performed by pasteurization for 10 h at 60°C. The bovine albumin for the hemagglutination tests used in immunohematology was submitted to chemical treatment with 0.06% (w/v) glutaraldehyde and 0.1% (w/v) formaldehyde at 37°C for 12 h to obtain polymerization. A change in molecular distribution was observed after this treatment, with average contents of 56.0% monomers, 23.6% dimers, 12.2% trimers and 8.2% polymers. The tests performed demonstrated that this polymerized albumin enhances the agglutination of Rho(D)-positive red cells by anti-Rho(D) serum, permitting and improving visualization of the results.
Resumo:
We determined the relationship between plasma and red blood cell concentrations of quinine in children with uncomplicated falciparum malaria from an endemic area of Amazonian region. Quinine was determined by high performance liquid chromatography with ultraviolet detection. In the steady state the ratio between plasma and red blood cell quinine concentration was 1.89 ± 1.25 ranging from 1.05 to 2.34. This result demonstrated that quinine do not concentrate in red blood cell of Brazilian children and characterize the absence of interracial difference in this relationship.
Resumo:
The objective of this work was to determine the contribution of dissolved organic carbon (DOC) from a biochar mineral complex (BMC), so as to better understand the interactions between DOC, biochar, clay, and minerals during thermal treatment, and the effects of BMC on amended soils. The BMC was prepared by heating a mixture of a H3PO4-treated saligna biochar from Acacia saligna, clays, other minerals, and chicken manure. The BMC was applied to a sandy loam soil in Western Australia, where wheat was grown. Liquid chromatography-organic carbon detection (LC-OCD) tests were carried out on water extracts from the untreated biochar, the BMC, the BMC-amended soil, and on a control soil to measure the DOC concentration. LC-OCD tests provide a fingerprint of the DOC, which allows the fractions of DOC to be determined. Thermal processing enhanced the reaction of the A. saligna biochar with manure, clays and minerals, and affected the distribution of the DOC fractions. Notably, the process leads to immobilization of hydrophobic DOC and to an increase in the concentration of low-molecular-weight neutrals in the BMC. The application of the BMC to soil increases the DOC in the amended soil, especially the biopolymer fraction.
Resumo:
Pereskia aculeata Mill. (Ora-pro-nóbis) is a native cactaceae from tropical America, whose leaves have high protein content. In Brazil it is found in all territorial extension between the states of Bahia and Rio Grande do Sul. Most studies have focused on chemical characterization of the leaves of this specie. The objective was to assess the carotenoids profile and the total polyphenols present in the fruits of P. aculeate. Carotenoids were determined by HPLC-PAD (high performance liquid chromatography - photodiode array detector), total polyphenols were determined by Folin-Ciocalteu and vanillin methods. Trans-β-carotene was the main carotenoid, followed by α-carotene, lutein and other minor carotenoids. It was found 64.9 ± 1.1 mg.100g-1 of gallic acid equivalent, 14.8 ± 0.2 mg.100g-1 of catechin equivalent. Carotenoid identification of P. aculeate fruits are presented here by the first time and indicate that these fruits can be researched as source of bioactive substances, especially antioxidant and provitamin A carotenoids.
Resumo:
This paper presents the study of adsorption/desorption of the explosive tetryl (2,4,6-trinitrophenylmethyl-nitramine) in different matrices, such as in natura soil, roasted soil, humic acid of soil, in natura peat, roasted peat and humic acid of peat. The aim of the study is to evaluate the interaction capacity of those matrices with the explosive. The analytic technique used was HPLC (high performance liquid chromatography), with UV-detection at 230 nm. The Freundlich isotherms were utilized for the mathematical treatment of the data. The results indicated that in natura soil and in natura peat (with organic substances) are excellent matrices for the retention of tetryl, adsorbing it and keeping it immovable, preventing it from contaminating the groundwater. The largest adsorption of the explosive ocurred in in natura soil, while the smallest desorption was observed in in natura peat. After the calcination of the matrices, the smallest adsorption was observed, indicating that the retention occurs in the organic substance.
Resumo:
Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.
Resumo:
The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.
Resumo:
This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.
Resumo:
An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples. The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v). Detection was carried out at an oxidation potential of +0.85V. The detector response was linear at concentration range of 7.50×10-8 - 1.50×10-6 mol L-1 (r = 0.997) for SA-14 and SV-24, respectively. The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.
Resumo:
A simple and rapid ultra-performance liquid chromatographic method for determination of oseltamivir in capsules was developed and validated. The mobile phase consisted of 5 mmol/L triethylammonium buffer (pH 3.0) and acetonitrile (70:30, v/v). Separation was performed in a Hypersil Gold® column, with octylsilil as stationary phase (100 x 2.1 mm, p.d. 1.9 µm). Chromatography run time was 1.2 min. The method presented adequate specificity, linearity, precision, ruggedness and accuracy and was adequate for determination of oseltamivir in capsules.
Resumo:
Tibolone is a synthetic steroid used for prevention of bone loss and treatment of menopause symptoms. This article describes the development and validation of an analytical method to quantify tibolone in capsules using high performance liquid chromatography with UV detection. After chromatography conditions are established the validation parameters evaluated were specificity, linearity, precision, accuracy, detection and quantification limits and robustness. The method developed is effective to analyze tibolone in capsules, being able to be used in quality control laboratory routine.
Resumo:
Tobacco cultivation in shallow soils and steep landscape under intense use of agrochemicals contributes to environment degradation. In this study, we assessed the concentration of agrochemicals in draw wells used for human consumption and a creek in a small catchment predominantly cropped to tobacco. Chlorpyrifos, flumetralin, and iprodione were determined by gas chromatography with electron capture detection, while imidalcloprid, atrazine, simazine, and clomazone were quantified by high-performance liquid chromatography with UV detection. Considering all sampling sites, all agrochemicals were detected at least once, except for flumetralin. The occurrence of agrochemicals in tobacco crops is a consequence of their fast transfer to surface water.
Resumo:
The aim of this work was to develop and validate an analytical method for the quantification of tioconazole in polymeric nanocapsule suspensions by high performance liquid chromatography with UV detection. The analysis was performed with a mobile phase composed of methanol:water (80:20) and 0.18% ammonium hydroxide; RP-18 column and UV detection at 219 nm. The method proved to be linear in the concentration range of 5-50 µg mL-1 (r = 0.9999), specific, precise (repeatability RSD = 1.42%, intermediate precision RSD = 1.17%), accurate (98 - 102%) and robust (RSD < 2.0%). In conclusion, a simple and rapid method was validated proving suitable for quantification of tioconazole in polymeric nanocapsules.
Resumo:
It has been suggested that the measurement of metronidazole clearance is a sensitive method for evaluating liver function. The aim of this study was to evaluate the usefulness of plasma hydroxy-metronidazole/metronidazole ratios as indicators of dynamic liver function to detect changes resulting from the various forms of chronic hepatitis C virus (HCV) infection. A total of 139 individuals were studied: 14 healthy volunteers, 22 healthy, asymptomatic, consecutive anti-HCV-positive HCV-RNA negative subjects, 81 patients with chronic hepatitis C (49 with moderate/severe chronic hepatitis and 34 with mild hepatitis), and 20 patients with cirrhosis of the liver. HCV status was determined by the polymerase chain reaction. Plasma concentrations of metronidazole and its hydroxy-metabolite were measured by reverse-phase high-performance liquid chromatography with ultraviolet detection in a blood sample collected 10 min after the end of a metronidazole infusion. Anti-HCV-positive HCV-RNA-negative individuals demonstrated a significantly reduced capacity to metabolize intravenously infused metronidazole compared to healthy individuals (0.0478 ± 0.0044 vs 0.0742 ± 0.0232). Liver cirrhosis patients also had a reduced plasma hydroxy-metronidazole/metronidazole ratio when compared to the other groups of anti-HCV-positive individuals (0.0300 ± 0.0032 vs 0.0438 ± 0.0027 (moderate/severe chronic hepatitis) vs 0.0455 ± 0.0026 (mild chronic hepatitis) and vs 0.0478 ± 0.0044 (anti-HCV-positive, HCV-RNA-negative individuals)). These results suggest an impairment of the metronidazole metabolizing system induced by HCV infection that lasts after viral clearance. In those patients with chronic hepatitis C, this impairment is paralleled by progression of the disease to liver cirrhosis.