170 resultados para Human perfectibility
Resumo:
The surface of human syncytiotrophoblast does not induce maternal blood platelet aggregation even though it is not an endothelium. It can be surmised that as occurs in endothelial injury the subcellular components of the syncytiotrophoblast may have pro-or antiaggregatory activity. During congenital Chagas' disease which is associated to trophoblast lesions, platelets may play a role in the development of T. cruzi-induced placentitis. In the present work the aggregatory behaviour of normal human blood platelets was recorded after their challenging with subcellular fractions of syncytiotrophoblast isolated from normal and chagasic women. Nuclear, Mitochondrial, Microsomal and Supernatant fractions isolated from normal and chagasic syncytiotrophoblast failed to induce per se any aggregatory reaction on platelets. When samples of platelet-rich plasma (PRP) were preincubated with normal and chagasic nuclear fractions and then stimulated with collagen at threshold level (CT-PRP) an inhibition of the aggregatory response was observed. Treatment of CT-PRP with normal and chagasic mitochondrial fractions induced inhibition of platelet aggregation whereas only chagasic fraction reduced latency time. Microsornal fraction from normal placentas showed no significant effects on platelet aggregation. It is concluded that subcellular fractions of normal human syncytiotrophoblast do not exhibit any effect on platelet aggregation, whereas those subcellular fractions enriched in intracellular membrane components isolated from chagasic placentas inhibit platelet aggregation.
Resumo:
It was reevaluated a reduced schedule for anti-rabies post-exposure immunization with newborn mice nervous tissue vaccine (Fuenzalida 8c Palacios) in a group of 30 non exposed volunteers. The vaccine was administered by intramuscular injections on days zero, 2, 4, 16 and 27, in the deltoid area. Antibody levels were determinated by a simplified serum neutralization microtest on days zero, 16 and 37. On days 16 and 37 the antibody levels of the whole group was >0.5 IU/ml and >1.0 IU/ml, respectively. The cell mediated immunity was precociously detected (on day 4) by the delayed type hipersensitivity skin test. Our results show that this reduced schedule elicited an early and effective humoral and cellular immune response. However it is necessary other studies with larger groups of vaccinees in order to obtain definitive conclusion.
Resumo:
Total serum IgE, and Strongyloides - specific IgG and IgA antibodies were studied in 27 patients with parasitologically proven strongyloidiasis. Clinical manifestations in this case series were investigated by a restrospective study of the patient's records. Total serum IgE levels were elevated (greater than 250 IU/ml) in 59% of the patients (mean concentration = 1364 IU/ml). Parasite - specific IgG and IgA antibodies were detected by ELISA in the serum of 23 (85.2%) and 21 (77.8%) patients, respectively. Elevated serum IgE and clinical manifestations were not useful indexes of the presence of strongyloidiasis. On the other hand, our results support the view that serologic tests, particularly ELISA for detecting Strongyloides - specific IgG antibodies, can be usefully exploited for diagnostic purposes in strongyloidiasis.
Resumo:
A 15 year old male patient was diagnosed as being infected with the nematode Lagochilascaris minor, presenting as abscesses over the left mastoid region, and invading the temporal bone, mastoid sinuses and possibly the CNS. Surgical drainage and administration of cambendazole and levamisole led to improvement, followed by an early relapse and poor tolerance to the antihelminthic drugs. Repeated doses of ivermectin (an animal preparation) were used for the first time to treat this condition and resulted in complete remission of signs of infection, maintained for 15 months after the end of drug therapy, indicating cure of the disease.
Resumo:
Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.
Resumo:
This paper reports the first case of human infection caused by Ttrichophyton vanbreuseghemii in Brazil.
Resumo:
In order to improve the diagnosis of human leptospirosis, we standardized the dot-ELISA for the search of specific IgM antibodies in saliva. Saliva and serum samples were collected simultaneously from 20 patients with the icterohemorrhagic form of the disease, from 10 patients with other pathologies and from 5 negative controls. Leptospires of serovars icterohaemorrhagiae, canicola, hebdomadis, brasiliensis and cynopteri grown in EMJH medium and mixed together in equal volumes, were used as antigen at individual protein concentration of 0.2 µg/µl. In the solid phase of the test we used polyester fabric impregnated with N-methylolacrylamide resin. The antigen volume for each test was 1µl, the saliva volume was 8 µl, and the volume of peroxidase-labelled anti-human IgM conjugate was 30 µl. A visual reading was taken after development in freshly prepared chromogen solution. In contrast to the classic nitrocellulose membrane support, the fabric support is easy to obtain and to handle. Saliva can be collected directly onto the support, a fact that facilitates the method and reduces the expenses and risks related to blood processing.
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
The authors report the clinical, laboratorial and epidemiological aspects of a human case of jungle yellow fever. The patient suffered from fever, chills, sweating, headaches, backaches, myalgia, epigastric pains, nausea, vomiting, diarrhea and prostration. He was unvaccinated and had been working in areas where cases of jungle yellow fever had been confirmed. Investigations concerning the yellow fever virus were performed. Blood samples were collected on several days in the course of the illness. Three of these samples (those obtained on days 5,7 and 10) were inoculated into suckling mice in attempt to isolate virus and to titrate the viremia level. Serological surveys were carried out by using the IgM Antibodies Capture Enzyme Linked Immunosorbent Assay (MAC-ELISA), Complement Fixation (CF), Hemagglulinalion Inhibition (HI) and Neutralization (N) tests. The yellow fever virus, recovered from the two first samples and the virus titration, showed high level of viremia. After that, specific antibodies appeared in all samples. The interval between the end of the viremia and the appearance of the antibodies was associated with the worsening of clinical symptoms, including bleeding of the mucous membrane. One must be aware of the risk of having a urban epidemics in areas where Aedes aegypti is found in high infestation indexes.
Resumo:
The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.
Resumo:
This study reports preliminary results of virus neutralizing antibody (VNA) titers obtained on different days in the course of human anti-rabies immunization with the 2-1-1 schedule (one dose is given in the right arm and one dose in the left arm at day 0, and one dose is apllied on days 7 and 21), recommended by WHO for post-exposure treatment with cell culture vaccines. A variant schedule (double dose on day zero and another on day 14) was also tested, both employing suckling mouse brain vaccine. A complete seroconversion rate was obtained after only 3 vaccine doses, and almost all patients (11 of 12) presented titers higher than 1.0 IU/ml. Both neutralizing response and seroconversion rates were lower in the group receiving only 3 doses, regardless of the sample collecting day. Although our results are lower than those found with cell culture vaccines, the geometry mean of VNA is fully satisfactory, overcoming the lower limit recommended by WHO of 0.5 IU/ml. The 2-1-1 schedule could be an alternative one for pre exposure immunization, shorter than the classical 3+1 regimen (one dose on days 0, 2, 4 and 30) with only three visits to the doctor, instead of four.