137 resultados para Filter methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Human T cell lymphotropic virus type 1 (HTLV-1) is endemic in the Caribbean, Japan, South America and regions of Africa. HTLV-2 is present in Native American populations and associated with IV drug use in Europe and North America. In Brazil, it is estimated that 1.5 million people are infected with HTLV-1/2. The study objective was to determine HTLV-1/2 prevalence in pregnant women in the prenatal care from three public services in São Luis, State of Maranhão, Brazil, and to counsel seropositive women to reduce viral transmission. METHODS: A cross-sectional study was conducted from February to December 2008; women with age of 18 to 45 years, with low risk for sexually transmitted disease (STD) were invited to participate. Blood samples were collected in filter paper, and HTLV-1/2 immunoenzymatic test (ELISA) was performed as a screening test. Women with reactive results were submitted to peripheral venous blood collection for ELISA repetition, followed by Western blot (WB) and real-time PCR to confirm and discriminate the infection between virus types 1 and 2. RESULTS: Of the 2,044 women tested, seven (0.3%) were ELISA reactive and confirmed positive (four were HTLV-1, and three were HTLV-2). All positive women were oriented not to breastfeed their newborns. CONCLUSIONS: This study showed that the virus is present in high prevalence in that population. Further studies covering other segments of the population are necessary to better characterize the presence of HTLV-1/2 in Maranhão and to elicit measures to prevent its spread.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Antifungal susceptibility testing assists in finding the appropriate treatment for fungal infections, which are increasingly common. However, such testing is not very widespread. There are several existing methods, and the correlation between such methods was evaluated in this study. METHODS: The susceptibility to fluconazole of 35 strains of Candida sp. isolated from blood cultures was evaluated by the following methods: microdilution, Etest, and disk diffusion. RESULTS: The correlation between the methods was around 90%. CONCLUSIONS: The disk diffusion test exhibited a good correlation and can be used in laboratory routines to detect strains of Candida sp. that are resistant to fluconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Trypanosoma cruzi, a flagellated protozoan, is the etiologic agent of Chagas disease, and it is estimated that approximately 5 million people in Brazil are infected with this parasite. This work aimed to compare the current diagnostic methods for Chagas disease, including conventional serological (IFAT and ELISA) and molecular techniques (PCR), to introduce PCR as an auxiliary technique. Methods A total of 106 chagasic patients were evaluated: 88 from endemic areas of Parana, 6 from São Paulo, 3 from Minas Gerais, 3 from Rio Grande do Sul, 1 from Bahia and 5 from the Santa Catarina T. cruzi outbreak. The samples were analyzed by conventional serological methods (IFAT, ELISA), hemoculture and PCR to confirm Chagas disease. Results When IFAT was used to determine antibody levels, the sensitivity was 81.7% for patients with the cardiac form of the disease and 100% for the other clinical forms. In contrast, ELISA showed 84% sensitivity and 100% specificity. The use of serological and molecular techniques and their implications for the diagnosis of Chagas disease in non-endemics area are discussed. Conclusions PCR constitutes an excellent support methodology for the laboratory diagnosis of Chagas disease due to its high sensitivity and specificity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Here, we evaluated sweeping methods used to estimate the number of immature Aedes aegypti in large containers. Methods III/IV instars and pupae at a 9:1 ratio were placed in three types of containers with, each one with three different water levels. Two sweeping methods were tested: water-surface sweeping and five-sweep netting. The data were analyzed using linear regression. Results The five-sweep netting technique was more suitable for drums and water-tanks, while the water-surface sweeping method provided the best results for swimming pools. Conclusions Both sweeping methods are useful tools in epidemiological surveillance programs for the control of Aedes aegypti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Toxoplasmosis may be life-threatening in fetuses and in immune-deficient patients. Conventional laboratory diagnosis of toxoplasmosis is based on the presence of IgM and IgG anti-Toxoplasma gondii antibodies; however, molecular techniques have emerged as alternative tools due to their increased sensitivity. The aim of this study was to compare the performance of 4 PCR-based methods for the laboratory diagnosis of toxoplasmosis. One hundred pregnant women who seroconverted during pregnancy were included in the study. The definition of cases was based on a 12-month follow-up of the infants. Methods Amniotic fluid samples were submitted to DNA extraction and amplification by the following 4 Toxoplasma techniques performed with parasite B1 gene primers: conventional PCR, nested-PCR, multiplex-nested-PCR, and real-time PCR. Seven parameters were analyzed, sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and efficiency (Ef). Results Fifty-nine of the 100 infants had toxoplasmosis; 42 (71.2%) had IgM antibodies at birth but were asymptomatic, and the remaining 17 cases had non-detectable IgM antibodies but high IgG antibody titers that were associated with retinochoroiditis in 8 (13.5%) cases, abnormal cranial ultrasound in 5 (8.5%) cases, and signs/symptoms suggestive of infection in 4 (6.8%) cases. The conventional PCR assay detected 50 cases (9 false-negatives), nested-PCR detected 58 cases (1 false-negative and 4 false-positives), multiplex-nested-PCR detected 57 cases (2 false-negatives), and real-time-PCR detected 58 cases (1 false-negative). Conclusions The real-time PCR assay was the best-performing technique based on the parameters of Se (98.3%), Sp (100%), PPV (100%), NPV (97.6%), PLR (∞), NLR (0.017), and Ef (99%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Açucena Municipality, Rio Doce Valley, State of Minas Gerais, Brazil temporarily (2001-2005) interrupted epidemiological surveillance for Chagas disease. The objective of this work was to evaluate the Chagas Disease Control Program (CDCP) in Açucena and to offer suggestions for improving local epidemiological surveillance. Methods This study was conducted in three phases: I) a serological investigation of schoolchildren aged 5 to 15 years using an enzyme-linked immunosorbent assay (ELISA) test performed on blood collected on filter paper followed by ELISA, indirect immunofluorescence (IIF) and indirect hemaglutination (IHA) on venous blood for borderline cases and those in the gray zone of reactivity; II) vector evaluation using the data obtained by local health agents during 2006-2010; and III) examination by ELISA, IIF and IHA of serum samples from the inhabitants of houses where infected Triatoma vitticeps was found and evaluation of their knowledge about Chagas disease. Results Five individuals had inconclusive results in the ELISA screening but were seronegative for Chagas disease. The triatomine evaluation revealed the presence of three species: Triatoma vitticeps, Panstrongylus megistus and Panstrongylus diasi. Triatoma vitticeps was the most prevalent and widespread, with a higher (67%) index of Trypanosoma cruzi flagellates and evidence of colonization. Most of the inhabitants of the infested houses recognized triatomines and had basic knowledge about Chagas disease. Conclusions Although T. vitticeps is not clearly associated with Chagas disease transmission, these results highlight the importance of maintaining CDCP in endemic areas and the need for greater emphasis on epidemiological surveillance, especially in areas with important vectorial changes or that have been modified by human intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The present study was designed to assess the occurrence of co-infection or cross-reaction in the serological techniques used for detecting the anti-Leishmania spp., -Babesia canis vogeli and -Ehrlichia canis antibodies in urban dogs from an area endemic to these parasites. METHODS: The serum samples from dogs were tested for the Babesia canis vogeli strain Belo Horizonte antigen and Ehrlichia canis strain São Paulo by immunofluorescence antibody test (IFAT) and by anti-Leishmania immunoglobulin G (IgG) antibody detection to assess Leishmania infection. We used the following four commercial kits for canine visceral leishmaniasis: ELISA, IFAT, Dual Path Platform (DPP) (Bio Manguinhos(r)/FIOCRUZ/MS) and a rK39 RDT (Kalazar Detect Canine Rapid Test; Inbios). RESULTS : Of 96 serum samples submitted to serological assays, 4 (4.2%) were positive for Leishmania as determined by ELISA; 12 (12.5%), by IFAT; 14 (14.6%) by rK39 RDT; and 20 (20.8%), by DPP. Antibodies against Ehrlichia and Babesia were detected in 23/96 (23.9%) and 30/96 (31.2%) samples, respectively. No significant association was identified between the results of tests for detecting Babesia or Ehrlichia and those for detecting Leishmania (p-value>0.05). CONCLUSIONS: In the present study, we demonstrated co-infection with Ehrlichia or Babesia and Leishmania in dogs from Minas Gerais (Brazil); we also found that the serological tests that were used did not cross-react.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: Leishmaniasis is a disease caused by the protozoan Leishmania that resides mainly in mononuclear phagocytic system tissues. Pentavalent antimonials are the main treatment option, although these drugs have toxic side effects and high resistance rates. A potentially alternative and more effective therapeutic strategy is to use liposomes as carriers of the antileishmanial agents. The aims of this study were to develop antimonial drugs entrapped into phosphatidylserine liposomes and to analyze their biological and physicochemical characteristics. METHODS: Liposomes containing meglumine antimoniate (MA) or pentavalent antimony salt (Sb) were obtained through filter extrusion (FEL) and characterized by transmission electron microscopy. Promastigotes of Leishmania infantum were incubated with the drugs and the viability was determined with a tetrazolium dye (MTT assay). The effects of these drugs against intracellular amastigotes were also evaluated by optical microscopy, and mammalian cytotoxicity was determined by an MTT assay. RESULTS: Liposomes had an average diameter of 162nm. MA-FEL showed inhibitory activity against intracellular L. infantum amastigotes, with a 50% inhibitory concentration (IC50) of 0.9μg/mL, whereas that of MA was 60μg/mL. Sb-FEL showed an IC50 value of 0.2μg/mL, whereas that of free Sb was 9μg/mL. MA-FEL and Sb-FEL had strong in vitro activity that was 63-fold and 39-fold more effective than their respective free drugs. MA-FEL tested at a ten-times higher concentration than Sb-FEL did not show cytotoxicity to mammalian cells, resulting in a higher selectivity index. CONCLUSIONS: Antimonial drug-containing liposomes are more effective against Leishmania-infected macrophages than the non-liposomal drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess, in myocardium specimens obtained from necropsies, the correlation between the concentration of hydroxyproline, measured with the photocolorimetric method, and the intensity of fibrosis, determined with the morphometric method. METHODS: Left ventricle myocardium samples were obtained from 45 patients who had undergone necropsy, some of them with a variety of cardiopathies and others without any heart disease. The concentrations of hydroxyproline were determined with the photocolorimetric method. In the histologic sections from each heart, the myocardial fibrosis was quantified by using a light microscope with an integrating ocular lens. RESULTS: A median of, respectively, 4.5 and 4.3 mug of hydroxyproline/mg of dry weight was found in fixed and nonfixed left ventricle myocardium fragments. A positive correlation occurred between the hydroxyproline concentrations and the intensity of fibrosis, both in the fixed (Sr=+0.25; p=0.099) and in the nonfixed (Sr=+0.32; p=0.03) specimens. CONCLUSION: The biochemical methodology was proven to be adequate, and manual morphometry was shown to have limitations that may interfere with the statistical significance of correlations for the estimate of fibrosis intensity in the human myocardium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess signal-averaged electrocardiogram (SAECG) for diagnosing incipient left ventricular hypertrophy (LVH). METHODS: A study with 115 individuals was carried out. The individuals were divided as follows: GI - 38 healthy individuals; GII - 47 individuals with mild to moderate hypertension and normal findings on echocardiogram and ECG; and GIII - 30 individuals with hypertension and documented LVH. The magnitude vector of the SAECG was analyzed with the high-pass cutoff frequency of 40 Hz through the bidirectional four-pole Butterworth high-pass digital filter. The mean quadratic root of the total QRS voltage (RMST) and the two-dimensional integral of the QRS area of the spectro-temporal map were analyzed between 0 and 30 Hz for the frequency domain (Int FD), and between 40 and 250 Hz for the time domain (Int TD). The electrocardiographic criterion for LVH was based on the Cornell Product. Left ventricular mass was calculated with the Devereux formula. RESULTS: All parameters analyzed increased from GI to GIII, except for Int FD (GII vs GIII) and RMST log (GII vs GIII). Int TD showed greater accuracy for detecting LVH with an appropriate cutoff > 8 (sensitivity of 55%, specificity of 81%). Positive values (> 8) were found in 56.5% of the G II patients and in 18.4% of the GI patients (p< 0.0005). CONCLUSION: SAECG can be used in the early diagnosis of LVH in hypertensive patients with normal ECG and echocardiogram.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the performance of the turbidimetric method of C-reactive protein (CRP) as a measure of low-grade inflammation in patients admitted with non-ST elevation acute coronary syndromes (ACS). METHODS: Serum samples obtained at hospital arrival from 68 patients (66±11 years, 40 men), admitted with unstable angina or non-ST elevation acute myocardial infarction were used to measure CRP by the methods of nephelometry and turbidimetry. RESULTS: The medians of C-reactive protein by the turbidimetric and nephelometric methods were 0.5 mg/dL and 0.47 mg/dL, respectively. A strong linear association existed between the 2 methods, according to the regression coefficient (b=0.75; 95% C.I.=0.70-0.80) and correlation coefficient (r=0.96; P<0.001). The mean difference between the nephelometric and turbidimetric CRP was 0.02 ± 0.91 mg/dL, and 100% agreement between the methods in the detection of high CRP was observed. CONCLUSION: In patients with non-ST elevation ACS, CRP values obtained by turbidimetry show a strong linear association with the method of nephelometry and perfect agreement in the detection of high CRP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Abdominal obesity is an important cardiovascular risk factor. Therefore, identifying the best method for measuring waist circumference (WC) is a priority. Objective: To evaluate the eight methods of measuring WC in patients with acute coronary syndrome (ACS) as a predictor of cardiovascular complications during hospitalization. Methods: Prospective study of patients with ACS. The measurement of WC was performed by eight known methods: midpoint between the last rib and the iliac crest (1), point of minimum circumference (2); immediately above the iliac crest (3), umbilicus (4), one inch above the umbilicus (5), one centimeter above the umbilicus (6), smallest rib and (7) the point of greatest circumference around the waist (8). Complications included: angina, arrhythmia, heart failure, cardiogenic shock, hypotension, pericarditis and death. Logistic regression tests were used for predictive factors. Results: A total of 55 patients were evaluated. During the hospitalization period, which corresponded on average to seven days, 37 (67%) patients had complications, with the exception of death, which was not observed in any of the cases. Of these complications, the only one that was associated with WC was angina, and with every cm of WC increase, the risk for angina increased from 7.5 to 9.9%, depending on the measurement site. It is noteworthy the fact that there was no difference between the different methods of measuring WC as a predictor of angina. Conclusion: The eight methods of measuring WC are also predictors of recurrent angina after acute coronary syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Postprandial Lipemia (PPL) is a physiological process that reflects the ability of the body to metabolize lipids. Even though the influence of oral contraceptives (OC) on PPL is not known, it is a known fact that their use increases fasting lipid values. Objective: To compare the PPL between women who are on OC and those who are not. Methods: A prospective analytical study which assessed eutrophic women, aged between 18 and 28 years old, who were irregularly active and with fasting triglycerides ≤150 mg/dL. They were divided into two groups: oral contraceptive group (COG) and non-oral contraceptive group (NCOG). Volunteers were submitted to the PPL test, in which blood samples were collected in time 0 (12-hour fasting) and after the intake of lipids in times 180 and 240 minutes. In order to compare the triglyceride deltas, which reflect PPL, the two-tailed Mann-Whitney test was used for independent samples between fasting collections and 180 minutes (Δ1) and between fasting and 240 minutes (Δ2). Results: Forty women were assessed and equally divided between groups. In the fasting lipid profile, it was observed that HDL did not present significant differences and that triglycerides in COG were twice as high in comparison to NCOG. Medians of Δ1 and Δ2 presented significant differences in both comparisons (p ≤0.05). Conclusion: The results point out that women who are irregularly active and use OC present more PPL in relation to those who do not use OC, which suggests that in this population, its chronic use increases the risk of heart conditions.