51 resultados para Equipment Failure Analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exercise capacity and quality of life (QOL) are important outcome predictors in patients with systolic heart failure (HF), independent of left ventricular (LV) ejection fraction (LVEF). LV diastolic function has been shown to be a better predictor of aerobic exercise capacity in patients with systolic dysfunction and a New York Heart Association (NYHA) classification ≥II. We hypothesized that the currently used index of diastolic function E/e' is associated with exercise capacity and QOL, even in optimally treated HF patients with reduced LVEF. This prospective study included 44 consecutive patients aged 55±11 years (27 men and 17 women), with LVEF<0.50 and NYHA functional class I-III, receiving optimal pharmacological treatment and in a stable clinical condition, as shown by the absence of dyspnea exacerbation for at least 3 months. All patients had conventional transthoracic echocardiography and answered the Minnesota Living with HF Questionnaire, followed by the 6-min walk test (6MWT). In a multivariable model with 6MWT as the dependent variable, age and E/e' explained 27% of the walked distance in 6MWT (P=0.002; multivariate regression analysis). No association was found between walk distance and LVEF or mitral annulus systolic velocity. Only normalized left atrium volume, a sensitive index of diastolic function, was associated with decreased QOL. Despite the small number of patients included, this study offers evidence that diastolic function is associated with physical capacity and QOL and should be considered along with ejection fraction in patients with compensated systolic HF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The physiological mechanisms involved in isoproterenol (ISO)-induced chronic heart failure (CHF) are not fully understood. In this study, we investigated local changes in cardiac aldosterone and its synthase in rats with ISO-induced CHF, and evaluated the effects of treatment with recombinant human brain natriuretic peptide (rhBNP). Sprague-Dawley rats were divided into 4 different groups. Fifty rats received subcutaneous ISO injections to induce CHF and the control group (n=10) received equal volumes of saline. After establishing the rat model, 9 CHF rats received no further treatment, rats in the low-dose group (n=8) received 22.5 μg/kg rhBNP and those in the high-dose group (n=8) received 45 μg/kg rhBNP daily for 1 month. Cardiac function was assessed by echocardiographic and hemodynamic analysis. Collagen volume fraction (CVF) was determined. Plasma and myocardial aldosterone concentrations were determined using radioimmunoassay. Myocardial aldosterone synthase (CYP11B2) was detected by quantitative real-time PCR. Cardiac function was significantly lower in the CHF group than in the control group (P<0.01), whereas CVF, plasma and myocardial aldosterone, and CYP11B2 transcription were significantly higher than in the control group (P<0.05). Low and high doses of rhBNP significantly improved hemodynamics (P<0.01) and cardiac function (P<0.05) and reduced CVF, plasma and myocardial aldosterone, and CYP11B2 transcription (P<0.05). There were no significant differences between the rhBNP dose groups (P>0.05). Elevated cardiac aldosterone and upregulation of aldosterone synthase expression were detected in rats with ISO-induced CHF. Administration of rhBNP improved hemodynamics and ventricular remodeling and reduced myocardial fibrosis, possibly by downregulating CYP11B2 transcription and reducing myocardial aldosterone synthesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The radial approach is widely used in the treatment of patients with coronary artery disease. We conducted a meta-analysis of published results on the efficacy and safety of the left and right radial approaches in patients undergoing percutaneous coronary procedures. A systematic search of reference databases was conducted, and data from 14 randomized controlled trials involving 6870 participants were analyzed. The left radial approach was associated with significant reductions in fluoroscopy time [standardized mean difference (SMD)=-0.14, 95% confidence interval (CI)=-0.19 to -0.09; P<0.00001] and contrast volume (SMD=-0.07, 95%CI=-0.12 to -0.02; P=0.009). There were no significant differences in rate of procedural failure of the left and the right radial approaches [risk ratios (RR)=0.98; 95%CI=0.77-1.25; P=0.88] or procedural time (SMD=-0.05, 95%CI=0.17-0.06; P=0.38). Tortuosity of the subclavian artery (RR=0.27, 95%CI=0.14-0.50; P<0.0001) was reported more frequently with the right radial approach. A greater number of catheters were used with the left than with the right radial approach (SMD=0.25, 95%CI=0.04-0.46; P=0.02). We conclude that the left radial approach is as safe as the right radial approach, and that the left radial approach should be recommended for use in percutaneous coronary procedures, especially in percutaneous coronary angiograms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the biological significance of microRNA-126 (miR-126) expression in patients with atrial fibrillation (AF) and/or heart failure (HF) to examine the possible mechanism of miR-126-dependent AF and development of HF. A total of 103 patients were divided into three groups: AF group (18 men and 17 women, mean age: 65.62±12.72 years), HF group (17 men and 15 women, mean age: 63.95±19.71 years), and HF-AF group (20 men and 16 women, mean age: 66.56±14.37 years). Quantitative real-time PCR was used to measure relative miR-126 expression as calculated by the 2−ΔΔCt method. miR-126 was frequently downregulated in the 3 patient groups compared with controls. This reduction was significantly lower in permanent and persistent AF patients than in those with paroxysmal AF (P<0.05, t-test). Moreover, miR-126 expression was markedly lower in the HF-AF group compared with the AF and HF groups. The 3 patient groups had higher N-terminal prohormone brain natriuretic peptide (NT-proBNP) levels, lower left ventricular ejection fraction (LVEF), larger left atrial diameter, and higher cardiothoracic ratio compared with controls. There were significant differences in NT-proBNP levels and LVEF among the AF, HF, and HF-AF groups. Pearson correlation analysis showed that relative miR-126 expression was positively associated with LVEF, logarithm of NT-proBNP, left atrial diameter, cardiothoracic ratio, and age in HF-AF patients. Multiple linear regression analysis showed that miR-126 expression was positively correlated with LVEF, but negatively correlated with the logarithm of NT-pro BNP and the cardiothoracic ratio (all P<0.05). Serum miR-126 levels could serve as a potential candidate biomarker for evaluating the severity of AF and HF. However, to confirm these results, future studies with a larger and diverse patient population are necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed at comparing both the results of wheat flour quality assessed by the new equipment Wheat Gluten Quality Analyser (WGQA) and those obtained by the extensigraph and farinograph. Fifty-nine wheat samples were evaluated for protein and gluten contents; the rheological properties of gluten and wheat flour were assessed using the WGQA and the extensigraph/farinograph methods, respectively, in addition to the baking test. Principal component analysis (PCA) and linear regression were used to evaluate the results. The parameters of energy and maximum resistance to extension determined by the extensigraph and WGQA showed an acceptable level for the linear correlation within the range from 0.6071 to 0.6511. The PCA results obtained using WGQA and the other rheological apparatus showed values similar to those expected for wheat flours in the baking test. Although all equipment used was effective in assessing the behavior of strong and weak flours, the results of medium strength wheat flour varied. WGQA has shown to use less amount of sample and to be faster and easier to use in relation to the other instruments used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Sugarcane monosaccharides are reducing sugars, and classical analytical methodologies (Lane-Eynon, Benedict, complexometric-EDTA, Luff-Schoorl, Musson-Walker, Somogyi-Nelson) are based on reducing copper ions in alkaline solutions. In Brazil, certain factories use Lane-Eynon, others use the equipment referred to as “REDUTEC”, and additional factories analyze reducing sugars based on a mathematic model. The objective of this paper is to understand the relationship between variations in millivolts, mass and tenors of reducing sugars during the analysis process. Another objective is to generate an automatic model for this process. The work herein uses the equipment referred to as “REDUTEC”, a digital balance, a peristaltic pump, a digital camcorder, math programs and graphics programs. We conclude that the millivolts, mass and tenors of reducing sugars exhibit a good mathematical correlation, and the mathematical model generated was benchmarked to low-concentration reducing sugars (<0.3%). Using the model created herein, reducing sugars analyses can be automated using the new equipment.