90 resultados para Diagnostic Test Accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Herpes simplex virus type 1 (HSV-1) ophthalmic disease is the most common cause of corneal blindness in humans world-wide. Current culture techniques for HSV take several days and commercially available HSV laboratory based diagnostic techniques vary in sensitivity. Our study was conducted to evaluate the use of a quicker and simpler method to herpes ophthalmic diagnosis. Corneal smears were made by firm imprints of infected mouse eyes to glass slides, after smears were fixated with cold acetone, and an indirect immunofluorescence (IIF) method was performed using monoclonal antibodies in a murine model of ophthalmic herpes. Eye swabs from infected mice were inoculated in Vero cells for virus isolation. Cytology and histology of the eye were also performed, using hematoxylin-eosin routine. Mouse eyes were examined by slit-lamp biomicroscopy for evidence of herpetic disease at various times postinoculation. We made a comparative evaluation of sensitivity, specificity and speed of methods for laboratory detection of HSV. Our results indicate that this IIF method is quick, sensitive, specific and can be useful in the diagnosis of ophthalmic herpes as demonstrated in an animal model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toxoplasma gondii causes severe fetal disease during acute infection in pregnant women, thus demanding early diagnosis for effective treatment and fetus preservation. Fetal tests are inefficient and risky, and diagnosis is based on maternal IgM serology, which had weak screening ability due to increased sensitivity, with alternative IgG avidity tests. Here, we performed ELISA and avidity assays using a recombinant T. gondii antigen, rROP2, in samples from 160 pregnant women screened from a large public hospital who were referred due to positive IgM assays. IgG serology and avidity assays were compared using whole T. gondii extract or rROP2. ELISA IgG detection with rROP2 showed good agreement with assays performed with T. gondii extract, but rROP2 IgG avidity assays were unrelated to whole extract antigen IgG avidity, regardless of the chaotrope used. These data show that avidity maturation is specific to individual antigen prevalence and immune response during infection. ELISA rROP2 IgG assays may be an alternative serological test for the diagnosis of toxoplasmosis during pregnancy, although our data do not support their use in avidity assays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A direct immunofluorescent antibody (DIFMA) test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL) in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. The genera Enterococcus, Staphylococcus and Streptococcus are recognized as important Gram-positive human pathogens. The aim of this study was to evaluate the performance of Vitek 2 in identifying Gram-positive cocci and their antimicrobial susceptibilities. Methods. One hundred four isolates were analyzed to determine the accuracy of the automated system for identifying the bacteria and their susceptibility to oxacillin and vancomycin. Results. The system correctly identified 77.9% and 97.1% of the isolates at the species and genus levels, respectively. Additionally, 81.8% of the Vitek 2 results agreed with the known antimicrobial susceptibility profiles. Conclusion. Vitek 2 correctly identified the commonly isolated strains; however, the limitations of the method may lead to ambiguous findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Despite the known importance of Clostridium difficile as a nosocomial pathogen, few studies regarding Clostridium difficile infection (CDI) in Brazil have been conducted. To date, the diagnostic tests that are available on the Brazilian market for the diagnosis of CDI have not been evaluated. The aim of this study was to compare the performances of four commercial methods for the diagnosis of CDI in patients from a university hospital in Brazil. Methods Three enzyme immunoassays (EIAs) and one nucleic acid amplification test (NAAT) were evaluated against a cytotoxicity assay (CTA) and toxigenic culture (TC). Stool samples from 92 patients with suspected CDI were used in this study. Results Twenty-five (27.2%) of 92 samples were positive according to the CTA, and 23 (25%) were positive according to the TC. All EIAs and the NAAT test demonstrated sensitivities between 59 and 68% and specificities greater than 91%. Conclusions All four methods exhibited low sensitivities for the diagnosis of CDI, which could lead to a large number of false-negative results, an increased risk of cross-infection to other patients, and overtreatment with empirical antibiotics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: Acceptance of the IT LEISH(r) and direct agglutination test- made in the Laboratório de Pesquisas Clínicas (DAT-LPC) by healthcare professionals and patients suspected of visceral leishmaniasis (VL) in Ribeirão das Neves was evaluated. METHODS: Ninety-two patients and 47 professionals completed three questionnaires. RESULTS: Eighty-eight (96%) patients considered fingertip blood collection a positive test feature, and 86% (37) and 91% of professionals considered the IT LEISH(r) easy to perform and interpret, respectively. All professionals classified the DAT-LPC as simple and easy. CONCLUSIONS: Patients and healthcare professionals in Ribeirão das Neves demonstrated a high degree of acceptance of the IT LEISH(r) and DAT-LPC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the efficiency of a systematic diagnostic approach in patients with chest pain in the emergency room in relation to the diagnosis of acute coronary syndrome (ACS) and the rate of hospitalization in high-cost units. METHODS: One thousand and three consecutive patients with chest pain were screened according to a pre-established process of diagnostic investigation based on the pre-test probability of ACS determinate by chest pain type and ECG changes. RESULTS: Of the 1003 patients, 224 were immediately discharged home because of no suspicion of ACS (route 5) and 119 were immediately transferred to the coronary care united because of ST elevation or left bundle-branch block (LBBB) (route 1) (74% of these had a final diagnosis of acute myocardial infarction [AMI]). Of the 660 patients that remained in the emergency room under observation, 77 (12%) had AMI without ST segment elevation and 202 (31%) had unstable angina (UA). In route 2 (high probability of ACS) 17% of patients had AMI and 43% had UA, whereas in route 3 (low probability) 2% had AMI and 7 % had UA. The admission ECG has been confirmed as a poor sensitivity test for the diagnosis of AMI ( 49%), with a positive predictive value considered only satisfactory (79%). CONCLUSION: A systematic diagnostic strategy, as used in this study, is essential in managing patients with chest pain in the emergency room in order to obtain high diagnostic accuracy, lower cost, and optimization of the use of coronary care unit beds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractBackground:Guidelines recommend that in suspected stable coronary artery disease (CAD), a clinical (non-invasive) evaluation should be performed before coronary angiography.Objective:We assessed the efficacy of patient selection for coronary angiography in suspected stable CAD.Methods:We prospectively selected consecutive patients without known CAD, referred to a high-volume tertiary center. Demographic characteristics, risk factors, symptoms and non-invasive test results were correlated to the presence of obstructive CAD. We estimated the CAD probability based on available clinical data and the incremental diagnostic value of previous non-invasive tests.Results:A total of 830 patients were included; median age was 61 years, 49.3% were males, 81% had hypertension and 35.5% were diabetics. Non-invasive tests were performed in 64.8% of the patients. At coronary angiography, 23.8% of the patients had obstructive CAD. The independent predictors for obstructive CAD were: male gender (odds ratio [OR], 3.95; confidence interval [CI] 95%, 2.70 - 5.77), age (OR for 5 years increment, 1.15; CI 95%, 1.06 - 1.26), diabetes (OR, 2.01; CI 95%, 1.40 - 2.90), dyslipidemia (OR, 2.02; CI 95%, 1.32 - 3.07), typical angina (OR, 2.92; CI 95%, 1.77 - 4.83) and previous non-invasive test (OR 1.54; CI 95% 1.05 - 2.27).Conclusions:In this study, less than a quarter of the patients referred for coronary angiography with suspected CAD had the diagnosis confirmed. A better clinical and non-invasive assessment is necessary, to improve the efficacy of patient selection for coronary angiography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was aimed at investigating alternate methods for serodiagnosis of tuberculosis (TB), which are needed because bacteriologic diagnosis of childhood TB is difficult. A selection of 80 serum and saliva samples were tested from Warao indigenous children under 15 years of age; 34 high TB suspects (28 positive and 6 negative for the tuberculin skin test, TST) and 46 healthy contact children (32 positive and 14 negative for the TST). Several enzyme-linked immunosorbent assay (ELISA) serological tests were developed to test for Mycobacterium tuberculosis-specific antibodies, including serum IgA, IgG, IgE, and secretory IgA (sIgA) in saliva against 3 specific antigens (PPD, HSP60, 38 kDa). Of these, 2 antigens, PPD and 38 kDa, showed significantly higher reactivity. The sensitivity and specificity of these tests for diagnosis remained limited, between 26.5% and 38.2%, and 77.4% and 97%, respectively. Of all the samples studied and combinations realized between all isotypes and antigens combined with 3 isotypes (anti-PPD IgG, IgE, and anti-38kDa sIgA) managed to detect the largest number of patients, showing an improved sensitivity level of 64.7%, although specificity levels dropped to 81.8%. These results were compared with the Omega diagnostics commercial kit results. The commercial kits showed significantly lower reactivity (sensitivity of 20% and 13.33% to Myco G and Complex Plus, respectively) and a specificity of 100%. This study shows that in indigenous populations of Venezuela, where invasive procedures cannot be used to select samples but evaluation with a chest X-ray for radiological studies is available, the combination of 3 specific isotypes may be a useful tool to increase diagnostic accuracy with pulmonary TB in this population, when used together with clinical and epidemiological criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

IgM-ELISA is an immunoenzymatic method useful for detection of IgM antibodies against a fraction of Schistosoma mansoni adult worm antigen (AWA) that is soluble in trichloroacetic acid (AWA-TCA). This method was applied to three groups of individuals with different clinical and epidemiological characteristics, and the results compared with those obtained by other diagnostic methods: immunofluorescence test for detection of IgM antibodies (IgM-IFT) or IgG antibodies (IgG-IFT), ELISA for detection of IgG antibodies (IgG-ELISA), and two parasitological methods, Kato-Katz and miracidium hatching. The IgM-ELISA presented a sensitivity of 98%, when the parasitologic fecal examination was defined as reference diagnostic method, and a specificity of 98 and 97.3%, respectively for the group of clinically healthy individuals and other helminth carriers. A comparative analysis between the results of IgM-ELISA and those obtained by other serologic tests showed a good degree of agreement, with Kappa indices ranging from 0.95 to 0.98. The diagnostic efficacy of 97.8%, as determined with schistosomiasis patients with low parasitic burden, suggests the excellent performance of the IgM-ELISA and its usefulness for the diagnosis of schistosomiasis when applied in low endemic areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new multiplex assay platform was evaluated to detect Trypanosoma cruzi infection using the recombinant antigens CRA, FRA, CRAFRA fusion and parasite lysate. The antigens presented different sensitivity and specificity in a singleplex test when compared to a serial dilution of two pools comprising 10 positive serum samples and one pool of 10 negative samples. The recombinant protein CRA presented lower sensitivity (55%) in contrast to the 100% specificity and sensitivity of FRA, CRAFRA and T. cruzi lysate. These antigens also showed good results in a duplex test and the duplex test with CRAFRA/T. cruzi lysate showed better performance with 100% specificity and sensitivity, as well as a lower cut-off value in comparison to the other duplex test, FRA/T. cruzi lysate. Hence, when the antigens were used in duplex format, both tests showed decreased cut-off values and no interference between different bead sets, resulting in increasing sensitivity and specificity. The results of these multiplex tests show that they could be an alternative to singleplex detection for Chagas disease, and also indicate the necessity of using multiplex diagnostic tools to increase the sensitivity and specificity for diagnostic tests. Emerging data from the T. cruzi genome and from its ORFeome project will also allow the identification of new antigens for this disease detection application.