89 resultados para Diagnostic, methods comparison
Resumo:
The liver abscess is the most frequent extraintestinal complication of intestinal amoebiasis: its diagnosis is suggested by the clinical picture but it must be confirmed by paraclinic tests. Themost stringent diagnosis requires identification of E. histolytica. But this is possible only in a few cases. Serological tests greatly improve the diagnosis of this severe complication of amoebiasis. We compared the Enzyme Linfed Immunosorbent Assay and the Counterimmunoeletrophoresis techniques. Both techniques were used to detect amoebic antibodies in 50 control patients, 30 patients with liver abscess and 30 patients with intestinal amoebiasis. All the sera from control patients gave negative results iin both techniques. When analysing the sera from patients with intestinal amoebiasis, 10% of them were positive by ELISA but non by CIE. The sera of patients with liver abscess, we found that 90% were positive by the ELISA method and 66.6% by the CIE technique. In patients with amoebic liver abscess, the results showed that the ELISA was more sensitive than the CIE, as it presented a higher sensitivity (100%) than that of the CIE technique (66%).
Resumo:
The purpose of this study was to compare the agar dilution and broth microdilution methods for determining the minimum inhibitory concentration (MIC) of fluconazole, itraconazole, ketoconazole, griseofulvin and terbinafine for 60 dermatophyte samples belonging to the species Trichophyton rubrum, Trichophyton mentagrophytes and Microsporum canis. The percentage agreement between the two methods, for all the isolates with < 2 dilutions that were tested was 91.6% for ketoconazole and griseofulvin, 88.3% for itraconazole, 81.6% for terbinafine and 73.3% for fluconazole. One hundred percent agreement was obtained for Trichophyton mentagrophytes isolates evaluated with ketoconazole and griseofulvin. Thus, until a reference method for testing the in vitro susceptibility of dermatophytes is standardized, the similarity of the results between the two methods means that the agar dilution method may be useful for susceptibility testing on these filamentous fungi.
Resumo:
INTRODUCTION: The present study compares human landing catches of primary malaria vectors with two alternative methods of capture: the Shannon trap and the Mosquito magnet. METHODS: This study used regression models to adjust capture data to a negative binominal distribution. RESULTS: Capture numbers and relative percentages obtained from the three methods vary strongly between species. The highest overall captures were obtained for Anopheles triannulatus with captures for the Shannon trap and the Mosquito magnet measuring more than 330% higher than captures obtained by human landings. For Anopheles darlingi, captures by the Shannon trap and the Mosquito magnet were about 14% and 26% of human landing catches, respectively. Another species with malaria transmission potential that was not sampled by human landing captures weascaptured by the Shannon trap and the Mosquito magnet (Anopheles oswaldoi). Both alternative sampling techniques can predict the human landing of Anopheles triannulatus, but without proportionality. Models for Anopheles darlingi counts, after totaling daily captures, are significant and proportional, but prediction models are more reliable when using the Shannon trap compared with the Mosquito magnet captures. CONCLUSIONS: These alternative capture methods can be partially recommended for the substitution of human landing captures or, at least, as complementary forms of monitoring for malarial mosquitoes.
Resumo:
Introduction Polymerase chain reaction (PCR) may offer an alternative diagnostic option when clinical signs and symptoms suggest visceral leishmaniasis (VL) but microscopic scanning and serological tests provide negative results. PCR using urine is sensitive enough to diagnose human visceral leishmaniasis (VL). However, DNA quality is a crucial factor for successful amplification. Methods A comparative performance evaluation of DNA extraction methods from the urine of patients with VL using two commercially available extraction kits and two phenol-chloroform protocols was conducted to determine which method produces the highest quality DNA suitable for PCR amplification, as well as the most sensitive, fast and inexpensive method. All commercially available kits were able to shorten the duration of DNA extraction. Results With regard to detection limits, both phenol: chloroform extraction and the QIAamp DNA Mini Kit provided good results (0.1 pg of DNA) for the extraction of DNA from a parasite smaller than Leishmania (Leishmania) infantum (< 100fg of DNA). However, among 11 urine samples from subjects with VL, better performance was achieved with the phenol:chloroform method (8/11) relative to the QIAamp DNA Mini Kit (4/11), with a greater number of positive samples detected at a lower cost using PCR. Conclusion Our results demonstrate that phenol:chloroform with an ethanol precipitation prior to extraction is the most efficient method in terms of yield and cost, using urine as a non-invasive source of DNA and providing an alternative diagnostic method at a low cost.
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
Background: Postprandial Lipemia (PPL) is a physiological process that reflects the ability of the body to metabolize lipids. Even though the influence of oral contraceptives (OC) on PPL is not known, it is a known fact that their use increases fasting lipid values. Objective: To compare the PPL between women who are on OC and those who are not. Methods: A prospective analytical study which assessed eutrophic women, aged between 18 and 28 years old, who were irregularly active and with fasting triglycerides ≤150 mg/dL. They were divided into two groups: oral contraceptive group (COG) and non-oral contraceptive group (NCOG). Volunteers were submitted to the PPL test, in which blood samples were collected in time 0 (12-hour fasting) and after the intake of lipids in times 180 and 240 minutes. In order to compare the triglyceride deltas, which reflect PPL, the two-tailed Mann-Whitney test was used for independent samples between fasting collections and 180 minutes (Δ1) and between fasting and 240 minutes (Δ2). Results: Forty women were assessed and equally divided between groups. In the fasting lipid profile, it was observed that HDL did not present significant differences and that triglycerides in COG were twice as high in comparison to NCOG. Medians of Δ1 and Δ2 presented significant differences in both comparisons (p ≤0.05). Conclusion: The results point out that women who are irregularly active and use OC present more PPL in relation to those who do not use OC, which suggests that in this population, its chronic use increases the risk of heart conditions.
Resumo:
Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.
Resumo:
Two practical field methods for indirect detection of simuliid populations resistant to temephos are proposed. The first is based on high esterase activity in resistant larvae and involves adaptations of a filter paper test in which faintly stained spots indicate susceptible populations and strongly stained ones reveal populations resistant to temephos. The second is based on the resistance to the larvicide when adults are topically exposed, and involves the use of diagnostic doses obtained by the comparison between the LD50 for susceptible and resistant populations. The relevance of such methods is discussed in order to help resistance detection in Simulium pertinax Kollar control programmes.
Resumo:
Two direct methods for the diagnosis of trichinellosis were compared: trichinoscopy and artificial digestion. Muscles from 17 wistar rats, orally infected with 500 Trichinella spiralis encysted larvae were examined. From each of the following muscles: diaphragm, tongue, masseters, intercostals, triceps brachialis and cuadriceps femoralis, 648,440 larvae from 1 g samples were recovered. The linear correlation between trichinoscopy and artificial digestion was very high and significant (r=0.94, p< 0.0001), showing that both methods for the detection of muscular larvae did not differ significantly. In both methods, significant differences were found in the distribution of larvae per gramme of muscle
Resumo:
At present, most Neisseria gonorrhoeae testing is done with ß-lactamase and agar dilution tests with common therapeutic agents. Generally, in bacteriological diagnosis laboratories in Argentina, study of antibiotic susceptibility of N.gonorrhoeae is based on ß-lactamase determination and agar dilution method with common therapeutic agents. The National Committee for Clinical Laboratory Standards (NCCLS) has recently described a disk diffusion test that produces results comparable to the reference agar dilution method for antibiotic susceptibility of N.gonorrhoeae, using a dispersion diagram for analyzing the correlation between both techniques. We obtained 57 gonococcal isolates from patients attending a clinic for sexually transmitted diseases in Tucumán, Argentina. Antibiotic susceptibility tests using agar dilution and disk diffusion techniques were compared. The established NCCLS interpretive criteria for both susceptibility methods appeared to be applicable to domestic gonococcal strains. The correlation between the MIC's and the zones of inhibition was studied for penicillin, ampicillin, cefoxitin, spectinomycin, cefotaxime, cephaloridine, cephalexin, tetracycline, norfloxacin and kanamycin. Dispersion diagrams showed a high correlation between both methods.
Resumo:
A total of 106 women with vaginitis in Nicaragua were studied. The positive rate for the identification of Candida species was 41% (44 positive cultures out of 106 women with vaginitis). The sensitivity of microscopic examination of wet mount with the potassium hydroxide (KOH) was 61% and 70% with Gram's stain when using the culture of vaginal fluid as gold standard for diagnosis of candidiasis. Among the 44 positives cultures, isolated species of yeast from vaginal swabs were C. albicans (59%), C. tropicalis (23%), C. glabrata (14%) and C. krusei (4%). This study reports the first characterization of 26 C. albicans stocks from Nicaragua by the random amplified polymorphic DNA method. The genetic analysis in this small C. albicans population showed the existence of linkage disequilibrium, which is consistent with the hypothesis that C. albicans undergoes a clonal propagation.
Resumo:
The sensitivities of spleen and lymph node cultures for the diagnosis of canine visceral leishmaniasis were compared in 64 anti-Leishmania antibody positive dogs from an endemic area in Brazil. The sensitivity of spleen cultures for Leishmania detection was 97.9%; in lymph node cultures it was 25%. Positive spleen culture was more frequent (p = 0.048, Fisher's exact probability test) in symptomatic (28 out of 33 animals) than in asymptomatic animals (19 out of 31 animals). These results support the use of spleen instead of lymph node aspiration as the choice method for the parasitological diagnosis of the infection.
Resumo:
Coagulase-negative staphylococci (CNS) species identification is still difficult for most clinical laboratories. The scheme proposed by Kloos and Schleifer and modified by Bannerman is the reference method used for the identification of staphylococcal species and subspecies; however, this method is relatively laborious for routine use since it requires the utilization of a large number of biochemical tests. The objective of the present study was to compare four methods, i.e., the reference method, the API Staph system (bioMérieux) and two methods modified from the reference method in our laboratory (simplified method and disk method), in the identification of 100 CNS strains. Compared to the reference method, the simplified method and disk method correctly identified 100 and 99% of the CNS species, respectively, while this rate was 84% for the API Staph system. Inaccurate identification by the API Staph method was observed for Staphylococcus epidermidis (2.2%), S. hominis (25%), S. haemolyticus (37.5%), and S. warneri (47.1%). The simplified method using the simple identification scheme proposed in the present study was found to be efficient for all strains tested, with 100% sensitivity and specificity and proved to be available alternative for the identification of staphylococci, offering, higher reliability and lower cost than the currently available commercial systems. This method would be very useful in clinical microbiology laboratory, especially in places with limited resources.
Resumo:
In this study we compared two polymerase chain reaction (PCR) methods using either 16S ribosomal RNA (rRNA) or 23S rRNA gene primers for the detection of different Leptospira interrogans serovars. The performance of these two methods was assessed using DNA extracted from bovine tissues previously inoculated with several bacterial suspensions. PCR was performed on the same tissues before and after the formalin-fixed, paraffin-embedding procedure (FFPE tissues). The 23S rDNA PCR detected all fresh and FFPE positive tissues while the 16S rDNA-based protocol detected primarily the positive fresh tissues. Both methods are specific for pathogenic L. interrogans. The 23S-based PCR method successfully detected Leptospira in four dubious cases of human leptospirosis from archival tissue specimens and one leptospirosis-positive canine specimen. A sensitive method for leptospirosis identification in FFPE tissues would be a useful tool to screen histological specimen archives and gain a better assessment of human leptospirosis prevalence, especially in tropical countries, where large outbreaks can occur following the rainy season.