70 resultados para Columns.
Resumo:
This paper presents the fundamental principles, instrumentation and selected applications of comprehensive two-dimensional gas chromatography (GC × GC). In this technique, introduced in 1991, two capillary columns are coupled and proper modulating interfaces continuously collect the eluate from the first column, transferring it to the second column. The result is a geometric increment in the chromatographic resolution, ensuring separation of extremely complex mixtures in time periods shorter or comparable to those of analysis using conventional gas chromatography and with better detectabilities and sensitivities.
Resumo:
Fixed-bed column studies were undertaken to evaluate the performance of a commercial Brazilian activated carbon in removing Pb(II) from aqueous environment. Breakthrough points were found out for the metal adsorption by varying different operating parameters like feed concentrations (10 and 20 mg L-1) and bed heights (0.5, 1.5 and 2.8 cm). A good agreement was observed between the experimental data and the values predicted by the bed depth service time (BDST) model. Regeneration of the exhausted columns was possible with HCl, and the adsorption capacity was maintained after three adsorption-desorption cycles.
Resumo:
This work evaluated the use of the Hildebrand/Hansen solubility parameters for selection of solvents for extraction of the organochlorine pesticides pp' DDT, pp' DDE, Aldrin and a-Endossulfan from soil using columns packed with Al2O3. The mixtures hexane:dichloromethane (7:3; v/v), hexane:acetonitrile (1:1; v/v), hexane:acetone (1:1; v/v) and pure hexane were chosen as extracting solutions. In the addition and recovery tests, different extraction solutions provided high recoveries percentages (>75%) with coefficients of variation below 15%. The recoveries are in agreement with the Hildebrand/Hansen parameters, demonstrating its applicability in the selection of extracting solution and in the replacement of toxic solvents, as dichloromethane
Resumo:
The aim of this review is to take a look at Cold War era nuclear tests signatures found in Brazilian coastal sediments. Both137Cs and 240+239Pu signatures have been documented in mangrove, coastal mudflats and continental shelf sediments, associated with above ground nuclear tests beginning in the 1950's. The dates associated to the anthropogenic radionuclide signatures 137Cs and 240+239Pu along sediment columns are confirmed by 210Pb geochronology in many of the studies highlighted in this review. The results outlined in this review characterize the extent to which nuclear fallout products reach the Brazilian coast in quantities sufficient for detection, allowing the use of these radioisotopes as geochronometers.
Resumo:
Two parallel tests were carried out to evaluate barium solubility in soils treated with barite under reducing conditions: one in leaching columns and another with potted plants cultivated with rice. Soils were treated with three doses of barite and kept at two humidity levels. The reduction (-200 mV) condition promoted an increase in barium in the geochemical fraction of higher liability, higher concentrations of barium in the leached extracts, and higher absorption by rice plants. As a result of increased uptake and accumulation of barium, the plants showed stunted growth
Resumo:
While in Europe vodka is mainly derived from potatoes or cereals, a large proportion of Brazilian vodka is likely obtained from sugarcane, which contains ethyl carbamate (EC) precursors. EC, in addition to several other contaminants and congeners, were investigated in 32 samples of Brazilian vodka. All samples complied with the Brazilian regulations for congeners and contaminants, having EC content below 0.01 mg/L (detection limit). These results are probably related to the processing of vodka, in particular the use of extractive and rectifying stainless steel distillation columns, which allow the production of high strength spirits with low levels of congeners and contaminants.
Resumo:
Spent nickel-cadmium (Ni-Cd) batteries and salts of nickel and cadmium were placed in two different columns of soil for a period of two years. A leaching solution was passed through them at ambient temperature in this period. The behavior of metals in each column was then evaluated. Under the conditions of the experiment, cadmium and nickel demonstrated the potential to contaminate and affect the natural cycles of soil. The disposal of Ni-Cd batteries directly to the soil also increased the concentration of nickel (349 mg kg-1) and cadmium (2890 mg kg-1), sometimes exceeding the intervention values defined in CONAMA resolution 420/09.
Resumo:
This paper describes the optimization of a multiresidue chromatographic analysis for the identification and quantification of 20 pesticides in bovine milk, including three carbamates, a carbamate oxime, six organophosphates, two strobilurins, a pyrethroid, an oxazolidinedione, an aryloxyphenoxypropionate acid/ester, a neonicotinoid, a dicarboximide, and three triazoles. The influences of different chromatographic columns and gradients were evaluated. Furthermore, four different extraction methods were evaluated; each utilized both different solvents, including ethyl acetate, methanol, and acetonitrile, and different workup steps. The best results were obtained by a modified QuEChERS method that lacked a workup step, and that included freezing the sample for 2 hours at -20 ºC. The results were satisfactory, yielding coefficients of variation of less than 20%, with the exception of the 50 µg L-1 sample of famoxadone, and recoveries between 70 and 120%, with the exception of acephate and bifenthrin; however, both analytes exhibited coefficients of variation of less than 20%.
Resumo:
The filling of capillaries via the sol-gel process is growing. Therefore, this technical note focuses on disseminating knowledge acquired in the Group of Analytical Chemistry and Chemometrics over seven years working with monolithic stationary phase preparation in fused silica capillaries. We believe that the detailed information presented in this technical note concerning the construction of an alternative high pressurization device, used to fill capillary columns via the sol-gel process, which has promising potential for applications involving capillary electrochromatography and liquid chromatography in nano scale, may be enlightening and motivating for groups interested in developing research activities within this theme.
Resumo:
Hydrophilic interaction liquid chromatography (HILIC) has been gaining increased attention for its effective separation of highly polar compounds, which include carbohydrates, amino acids, pharmaceutical compounds, proteins, glycoproteins, nucleosides, etc. Polar compounds are usually poorly retained on reverse-phase liquid chromatography (RP-HPLC) columns or have poor solubility in the apolar mobile phase of normal-phase high performance liquid chromatography (NP-HPLC). Since HILIC uses organic solvents such as ACN or MeOH ( > 70%), also used in RP-HPLC and polar stationary phases similar to NP-HPLC (bare silica, diol, amino, amide, saccharide, zwitterionic stationary phases, etc.), it represents a hybrid of the two separation modes. The high organic content in the MP leads to good compatibility with mass spectrometry (MS), increasing the detectivity. This review describes the fundamentals of HILIC and highlights some interesting applications.
Resumo:
Styrene is used in a variety of chemical industries. Environmental and occupational exposures to styrene occur predominantly through inhalation. The major metabolite of styrene is present in two enantiomeric forms, chiral R- and S- hydroxy-1-phenyl-acetic acid (R-and S-mandelic acid, MA). Thus, the concentration of MA, particularly of its enantiomers, has been used in urine tests to determine whether workers have been exposed to styrene. This study describes a method of analyzing mandelic acid using molecular imprinting techniques and HPLC detection to perform the separation of diastereoisomers of mandelic acid. The molecularly imprinted polymer (MIP) was prepared by non-covalent molecular imprinting using (+) MA, (-) MA or (+) phenylalanine, (-) phenylalanine as templates. Methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were copolymerized in the presence of the template molecules. The bulk polymerization was carried out at 4ºC under UV radiation. The resulting MIP was grounded into 25~44¼m particles, which were slurry packed into analytical columns. After the template molecules were removed, the MIP-packed columns were found to be effective for the chromatographic resolution of (±)-mandelic acid. This method is simpler and more convenient than other chromatographic methods.
Resumo:
Round timber has great use in civil construction, performing the function of beams, columns, foundations, poles for power distribution among others, with the advantage of not being processed, such as lumber. The structural design of round timber requires determining the elastic properties, mainly the modulus of elasticity. The Brazilian standards responsible for the stiffness and strength determination of round timber are in effect for over twenty years with no technical review. Round timber, for generally present an axis with non-zero curvature according to the position of the element in the bending test, may exhibit different values of modulus of elasticity. This study aims to analyze the position effect of Eucalyptus grandis round timber on the flexural modulus of elasticity. The three-point bending test was evaluated in two different positions based on the longitudinal rotation of the round timber element. The results revealed that at least two different positions of the round timber element are desired to obtain significant modulus of elasticity.
Resumo:
The aim of this study was to characterize the spatial variability of soil bulk density (Bd), soil moisture content (θ) and total porosity (Tp) in two management systems of sugarcane harvesting, with or without burning, in a Haplustox soil, in the 0-0.20 m layer. The study area is located in Rio Brilhante, state of Mato Grosso do Sul, Brazil, in Eldorado Sugar Mill. The plots have presented 180 m length, and 145.6 m width, totaling 90 points distributed in the form of a grid of nine rows by ten columns, with points spaced 20 m from its neighbor. Soil samples were collected at 0-0.20 m layer in 2007/2008 and 2008/2009 crops. The harvest with burning system had a higher density compared to mechanized harvest, in the two study periods. The moisture content as well as the porosity increased proportionally with the decrease of the density of the harvest burning system compared to the mechanized.
Resumo:
The potassium ion, present in great amount in the vinasse because it is a monovalent cation, has the characteristic of promoting the dispersion of clay particles, in the same way as the sodium, causing a reduction in the pore space of the soil and, in its turn, reducing its permeability. To evaluate this effect of reduction by application of vinasse to the soil, an experiment was conducted for three different soils, with the objective of evaluating the effect of the application of different doses of vinasse on hydraulic conductivity of saturated soil and verifying its possible chemical changes of these soils. For that, it was used PVC columns (in a scheme of constant head permeameter to obtain the values of hydraulic conductivity of saturated soil), filled with three soils - Dark Red Latosol (DRL), Purple Latosol (PL) and Eutrophic Red Nitossol (ERN) - , in which were applied four doses of vinasse (0, 150, 300 and 450m³ ha-1), distributed in a completely randomized design with a 3x4 factorial scheme with three replications. The results evidenced that only the Dark Red Latosol (DRL) showed a reduction in the values of hydraulic conductivity of saturated soil, and in front of the application of vinasse, up to 300m³ ha-1, it was observed an increase in the concentrations of potassium, calcium and cation exchange capacity (CEC) ions.
Resumo:
The determination of volumetric water content of soils is an important factor in irrigation management. Among the indirect methods for estimating, the time-domain reflectometry (TDR) technique has received a significant attention. Like any other technique, it has advantages and disadvantages, but its greatest disadvantage is the need of calibration and high cost of acquisition. The main goal of this study was to establish a calibration model for the TDR equipment, Trase System Model 6050X1, to estimate the volumetric water content in a Distroferric Red Latosol. The calibration was carried out in a laboratory with disturbed soil samples under study, packed in PVC columns of a volume of 0.0078m³. The TDR probes were handcrafted with three rods and 0.20m long. They were vertically installed in soil columns, with a total of five probes per column and sixteen columns. The weightings were carried out in a digital scale, while daily readings of dielectric constant were obtained in TDR equipment. The linear model θν = 0.0103 Ka + 0.1900 to estimate the studied volumetric water content showed an excellent coefficient of determination (0.93), enabling the use of probes in indirect estimation of soil moisture.