87 resultados para Cochlear Implantation
Resumo:
OBJECTIVE: To compare the outcome of balloon PTCA with final coronary stenosis diameter (SD) <=30%, with elective coronary stenting. METHODS: We performed a comparative analysis of the 6 month outcomes in patients treated with primary stenting and those who obtained an optimal balloon PTCA result treated during the first 12 hours of AMI onset included in the STENT PAMI randomized trial. RESULTS: The results were analysed into 3 groups: primary stenting (441 patients, SD=22±6%), optimal PTCA (245 patients), and nonoptimal PTCA (182 patients, SD= 37±5%). At the end of the 6 months primary stent group presented with the lowest restenosis(23 vs. 31 vs. 45%, p=0.001, respectively). Ischemia-driven target vessel revascularization rate (TVR) (7 vs. 15.5 vs. 19%, p=0.001, respectively). CONCLUSION: At the 6 month follow-up, primary stenting offered the lowest restenosis and ischemia-driven TVR rates. Compared to optimal balloon PTCA. Nonoptimal primary balloon PTCA pts (SD=31-50%), had the worst late angiographic outcomes and should be treated more actively with coronary stent implantation.
Resumo:
OBJECTIVE: Analysis of the in-hospital results, in progressively elderly patients who undergo primary percutaneous coronary intervention (PCI) in the first 24 hours of AMI. METHODS: The patients were divided into three different age groups (60/69, 70/79, and > or = 80 years) and were treated from 7/95 until 12/99. The primary success rate and the occurrence of major clinical events were analyzed at the end of the in-hospital phase. Coronary stent implantation and abciximab use were employed at the intervencionist discretion. RESULTS: We analyzed 201 patients with age ranging from 60 to 93 years, who underwent primary PCI. Patients with ages above 70 were more often female (p=.015). Those with ages above 80 were treated later with PCI (p=.054), and all of them presented with total occlusion of the infarct-related artery. Coronary stents were implanted in 30% of the patients. Procedural success was lower in > or = 80 year old patients (p=.022), and the death rate was higher in > or = 70 years olds (p=.019). Reinfarction and coronary bypass surgery were uncommon events. A trend occurred toward a higher combined incidence of major in-hospital events according to increased age (p=.064). CONCLUSION: Elderly patients ( > or = 70 years) presented with adverse clinical and angiographic profiles and patients > or = 80 years of age obtained reduced TIMI 3 flow success rates after primary PTCA, and those > or = 70 years had a higher death rate.
Resumo:
After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.
Resumo:
OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.
Resumo:
OBJECTIVE: This study was performed to observe the number of pacemakers that had never been reprogrammed after implantation, and the effect of optimised output programming on estimated longevity of pulse generators in patients with pacemaker METHODS: Sixty patients with Teletronics Reflex pacemakers were evaluated in a pacemaker clinic, from the time of the beginning of its activities, in June 1998, until March 1999. Telemetry was performed during the first clinic visit, and we observed how many pulse generators retained nominal output settings of the manufactures indicating the absence of reprogramming until that date. After evaluation of the capture threshold, reprogramming of pacemakers was performed with a safety margin of 2 to 2.5:1, and we compared the estimated longevity based on battery current at the manufacturer's settings with that based on settings achieved after reprogramming. RESULTS: In 95% of the cases, the original programmed setting was never reprogrammed before the patients attended the pacemaker clinic. Reprogramming the pacemaker prolonged estimated pulse generator life by 19.7±15.6 months (35.5%). CONCLUSION: The majority of the pacemakers evaluated had never been reprogrammed. Estimated pulse generator longevity can be prolonged significantly, using this simple, safe, efficacious, and cost-effective procedure.
Resumo:
OBJECTIVE: We conducted a comparative analysis of the in-hospital outcomes of patients who underwent primary percutaneous transluminal angioplasty (PTCA) or stent implantation because of an acute myocardial infarction (AMI) related to an acute vein graft occlusion. METHODS: Since 1991 the Brazilian Society of Hemodynamic and Interventional Cardiology has maintained a large database (CENIC). From these, we selected all consecutive patients, who underwent primary PTCA or stenting in the first 24 hours of AMI, with the target vessel being an occluded vein graft. Immediate results and major coronary events occurring up until hospital discharge were analyzed. RESULTS: During this period, 5,932 patients underwent primary PTCA or stenting; 158 (3%) of the procedures were performed because of an acute vein graft occlusion. Stenting was performed in 74 (47%) patients. Patients treated with stents had a higher success rate and lower mean residual stenosis compared with those who underwent primary balloon PTCA. The incidence of reinfarction and death were similar for stenting and balloon PTCA. CONCLUSION: Primary percutaneous treatment of AMI related to acute vein graft occlusion is still an uncommon practice. Primary stenting improved luminal diameter and offered higher rates of success; however, this strategy did not reduce the in-hospital reinfarction and death rate, compared with that occurring with PTCA treatment.
Resumo:
The patient is a 54-year-old asymptomatic male with a tumor in the right atrium that was diagnosed on transesophageal echocardiography and confirmed as a lipoma of the right atrium on computerized tomography. The patient underwent surgical repair with extracorporeal circulation. The tumor was resected, and its base of implantation in the atrium was repaired with a flap of bovine pericardium. The diagnosis of lipoma was confirmed on histopathological examination. Locating of the tumor with the aid of transesophageal echocardiography was very useful in the strategy of cannulation of the venae cava for installation of the circuit of extracorporeal circulation. The patient had a good postoperative evolution.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
PURPOSE: To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS: Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS: Sixteen patients were in NYHA class IV (66.6%) and 8 were in class III (33.4%). After 1-year follow-up, 14 patients were in class II (70%) and 5 were in class III (25%). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 ± 5.19% (at baseline) to 25.33 ± 5.90% (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 ± 12,595.39 SD or to a mean of 3,007.00 ± 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION: Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.
Resumo:
A 38-year-old man with acute myocardial infarction in the lower wall affecting the right ventricle underwent thrombolytic treatment with streptokinase. Approximately 2 hours after the thrombolytic treatment started, he presented with signs of coronary reocclusion. He underwent emergency cineangiocoronariography that revealed that his right coronary artery was completely occluded by a clot. He unsuccessfully underwent angioplasty and stent implantation. After the concomitant use of glycoprotein IIb/IIIa inhibitor, coronary TIMI III flow was achieved without additional dilations, and he was discharged from the hospital 5 days later with no further complications.
Resumo:
OBJECTIVE: To verify the results after the performance of primary coronary angioplasty in Brazil in the last 4 years. METHODS: During the first 24 hours of acute myocardial infarction onset, 9,434 (12.2%) patients underwent primary PTCA. We analyzed the success and occurrence of major in-hospital events, comparing them over the 4-year period. RESULTS: Primary PTCA use increased compared with that of all percutaneous interventions (1996=10.6% vs. 2000=13.1%; p<0.001). Coronary stent implantation increased (1996=20% vs. 2000=71.9%; p<0.001). Success was greater (1998=89.5% vs. 1999=92.5%; p<0.001). Reinfarction decreased (1998=3.9% vs. 99=2.4% vs. 2000=1.5%; p<0.001) as did emergency bypass surgery (1996=0.5% vs. 2000=0.2%; p=0.01). In-hospital deaths remained unchanged (1996=5.7% vs. 2000=5.1%, p=0.53). Balloon PTCA was one of the independent predictors of a higher rate of unsuccessful procedures (odds ratio 12.01 [CI=95%] 1.58-22.94), and stent implantation of lower mortality rates (odds ratio 4.62 [CI=95%] 3.19-6.08). CONCLUSION: The success rate has become progressively higher with a significant reduction in reinfarction and urgent bypass surgery, but in-hospital death remains nearly unchanged. Coronary stenting was a predictor of a lower death rate, and balloon PTCA was associated with greater procedural failure.
Resumo:
OBJECTIVE: To analyze the efficacy of percutaneous transluminal septal alcoholization in the treatment of refractory obstructive hypertrophic cardiomyopathy (HOC). METHODS: The patients were referred for alcoholization after Doppler echocardiography. Before and after alcoholization, the intraventricular pressure gradient was recorded. Alcoholization was performed with a 3mL injection of absolute alcohol through a coronary angioplasty balloon catheter. The procedure was concluded after a significant reduction or abolition of the pressure gradient. RESULTS: Of 22 patients, 18 (81.8%) successfully concluded the procedure with a reduction in intraventricular pressure gradient at baseline (from 67.6±24.2 mmHg to 3.8± 1.9 mmHg, p<0.005) and after extrasystole (from 110.4± 24.2 mmHg to 9.6±2.6 mm Hg, p<0.005). A significant reduction in mean interventricular septal thickness (from 2± 0.3 mm to 1.7±0.2 mm, p<0.005) and in peak pressure gradient (from 90.7±23.5 mmHg to 6.1±1.4 mmHg, p<0.005) was observed on Doppler echocardiography after 6 months, when all patients were in functional class I. The most frequent acute complication, present in 11% of the patients, was the need for definitive pacing implantation. Relapse of the symptoms and reappearance of the pressure gradient occurred in 16.6% of the patients. One patient (5.5%) died probably due to a diffuse coronary spasm prior to the procedure, and another died suddenly on late follow-up. CONCLUSION: Percutaneous transluminal septal alcoholization is effective and safe in the treatment of HOC.
Resumo:
The patient is a male with risk factors for coronary artery disease, who was referred for cardiac catheterization after acute myocardial infarction in the inferior wall. The patient underwent transluminal coronary angioplasty in the right coronary artery with successful stent implantation.
Resumo:
We report the case of implantation of metallic mitral and aortic valve prostheses 6 months earlier, with subsequent multiple embolic episodes. The anatomicopathological examination of the thrombus of the third embolic episode was compatible with Aspergillus sp, which was treated with amphotericin B, followed by oral itraconazole. On the fourth embolism, vegetations were visualized in the ascending aorta on echocardiography and resonance imaging, and the patient underwent replacement of the aortic segment by a Haemashield tube and exploration of the aortic prosthesis, which was preserved, because no signs of endocarditis were found. Four months later, the patient died due to cardiogenic shock secondary to acute myocardial infarction caused by probable coronary embolism and partial dysfunction of the aortic prosthesis.
Resumo:
OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.