40 resultados para repeat procedure
Resumo:
A RP-HPLC procedure for the simultaneous determination of cisplatin and the complex cis,cis,trans-diamminedichlorodihydroxo-platinum(IV), was development. The developed procedure was validated in terms of linearity, accuracy, precision, limits of detection (LOD), limits of quantification (LOQ) and specificity. The limits of detection (LOD) were 0.47 x 10-4 and 0.53 x 10-4 mol L-1 and the limits of quantification (LOQ) were 1.57 x 10-4 and 1.75 x 10-4 mol L-1, for cisplatin and cis,cis,trans-diamminedichlorodihydroxopla-tinum(IV), respectively. The average recoveries of cisplatin and cis,cis,trans-diamminedichlorodihydroxoplatinum(IV) was 100.6% ± 1.4 and 101.2% ± 1.1, respectively. Intermediate (inter-day) precision, repeatability and specificity of the procedure for hydrolysis products of cisplatin were studied. The results of the study showed that the proposed RP-HPLC procedure is simple, rapid, precise, accurate and specific.
Resumo:
An evaluation of the pesticides extracted from the soil matrix was conducted using a citrate-buffered solid phase dispersion sample preparation method (QuEChERS). The identification and quantitation of pesticide compounds was performed using gas chromatography-mass spectrometry. Because of the occurrence of the matrix effect in 87% of the analyzed pesticides, the quantification was performed using matrix-matched calibration. The method's quantification limits were between 0.01 and 0.5 mg kg-1. Repeatability and intermediate precision, expressed as a relative standard deviation percentage, were less than 20%. The recoveries in general ranged between 62% and 99%, with a relative standard deviation < 20%. All the responses were linear, with a correlation coefficient (r) ≥0.99.
Resumo:
Some aspects of the application of electrochemical impedance spectroscopy to studies of solid electrode / solution interface, in the absence of faradaic processes, are analysed. In order to perform this analysis, gold electrodes with (111) and (210) crystallographic orientations in an aqueous solution containing 10 mmol dm-3 KF, as supporting electrolyte, and a pyridine concentration varying from 0.01 to 4.6 mmol dm-3, were used. The experimental data was analysed by using EQUIVCRT software, which utilises non-linear least squares routines, attributing to the solid electrode / solution interface behaviour described by an equivalent circuit with a resistance in series with a constant phase element. The results of this fitting procedure were analysed by the dependence on the electrode potential on two parameters: the pre-exponential factor, Y0, and the exponent n f, related with the phase angle shift. By this analysis it was possible to observe that the pyridine adsorption is strongly affected by the crystallographic orientation of the electrode surface and that the extent of deviation from ideal capacitive behaviour is mainly of interfacial origin.
Resumo:
In order to a better characterization of a graphite-polyurethane composite intended to be used as a voltammetric sensor, the performance in a square wave voltammetric procedure was investigated. Using hydroquinone (HQ) as a probe, the electrode showed to be useful in square wave voltammetry with limit of detection of 0.28 µmol L-1, with recoveries between 99.1 and 101.5%. The results of the proposed method agreed with HPLC ones within 95% confidence level.
Resumo:
A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.
Resumo:
Objective: To evaluate the effectiveness and safety of correction of pectus excavatum by the Nuss technique based on the available scientific evidence.Methods: We conducted an evidence synthesis following systematic processes of search, selection, extraction and critical appraisal. Outcomes were classified by importance and had their quality assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE).Results: The process of selection of items led to the inclusion of only one systematic review, which synthesized the results of nine observational studies comparing the Nuss and Ravitch procedures. The evidence found was rated as poor and very poor quality. The Nuss procedure has increased the incidence of hemothorax (RR = 5.15; 95% CI: 1.07; 24.89), pneumothorax (RR = 5.26; 95% CI: 1.55; 17.92) and the need for reintervention (RR = 4.88; 95% CI: 2.41; 9.88) when compared to the Ravitch. There was no statistical difference between the two procedures in outcomes: general complications, blood transfusion, hospital stay and time to ambulation. The Nuss operation was faster than the Ravitch (mean difference [MD] = -69.94 minutes, 95% CI: -139.04, -0.83).Conclusion: In the absence of well-designed prospective studies to clarify the evidence, especially in terms of aesthetics and quality of life, surgical indication should be individualized and the choice of the technique based on patient preference and experience of the team.
Resumo:
In order to detect several new HLA-A class I alleles that have been described since 1998, the original PCR-RFLP method developed to identify the 78 alleles recognized at that time at high resolution level was adapted by us for low and medium resolution levels using a nested PCR-RFLP approach. The results obtained from blood samples of 23 subjects using both the PCR-RFLP method and a commercial kit (MicroSSP1A®, One Lambda Inc.) showed an agreement higher than 95%. The PCR-RFLP adapted method was effective in low and medium resolution histocompatibility evaluations.
Resumo:
Huntington's disease (HD) is an autosomal dominant neurodegenerative disorder that affects the striatum most severely. However, except for juvenile forms, relative preservation of the cerebellum has been reported. The objective of the present study was to perform MRI measurements of caudate, putamen, cerebral, and cerebellar volumes and correlate these findings with the length of the CAG repeat and clinical parameters. We evaluated 50 consecutive patients with HD using MRI volumetric measurements and compared them to normal controls. Age at onset of the disease ranged from 4 to 73 years (mean: 43.1 years). The length of the CAG repeat ranged from 40 to 69 (mean: 47.2 CAG). HD patients presented marked atrophy of the caudate and putamen, as well as reduced cerebellar and cerebral volumes. There was a significant correlation between age at onset of HD and length of the CAG repeat, as well as clinical disability and age at onset. The degree of basal ganglia atrophy correlated with the length of the CAG repeat. There was no correlation between cerebellar or cerebral volume and length of the CAG repeat. However, there was a tendency to a positive correlation between duration of disease and cerebellar atrophy. While there was a negative correlation of length of the CAG repeat with age at disease onset and with striatal degeneration, its influence on extrastriatal atrophy, including the cerebellum, was not clear. Extrastriatal atrophy occurs later in HD and may be related to disease duration.
Resumo:
Transtracheal puncture has long been known as a safe, low-cost procedure. However, with the advent of bronchoscopy, it has largely been forgotten. Two researchers have suggested the use of α-amylase activity to diagnose salivary aspiration, but the normal values of this enzyme in tracheobronchial secretions are unknown. We aimed to define the normal values of α-amylase activity in tracheobronchial secretions and verify the rate of major complications of transtracheal puncture. From October 2009 to June 2011, we prospectively evaluated 118 patients without clinical or radiological signs of salivary aspiration who underwent transtracheal puncture before bronchoscopy. The patients were sedated with a solution of lidocaine and diazepam until they reached a Ramsay sedation score of 2 or 3. We then cleaned the cervical region and anesthetized the superficial planes with lidocaine. Next, we injected 10 mL of 2% lidocaine into the tracheobronchial tree. Finally, we injected 10 mL of normal saline into the tracheobronchial tree and immediately aspirated the saline with maximum vacuum pressure to collect samples for measurement of the α-amylase level. The α-amylase level mean ± SE, median, and range were 1914 ± 240, 1056, and 24-10,000 IU/L, respectively. No major complications (peripheral desaturation, subcutaneous emphysema, cardiac arrhythmia, or hemoptysis) occurred among 118 patients who underwent this procedure. Transtracheal aspiration is a safe, low-cost procedure. We herein define for the first time the normal α-amylase levels in the tracheobronchial secretions of humans.
Resumo:
Yerba maté extracts have in vitro antioxidant capacity attributed to the presence of polyphenolic compounds, mainly chlorogenic acids and dicaffeoylquinic acid derivatives. DPPH is one of the most used assays to measure the antioxidant capacity of pure compounds and plant extracts. It is difficult to compare the results between studies because this assay is applied in too many different conditions by the different research groups. Thus, in order to assess the antioxidant capacity of yerba maté extracts, the following procedure is proposed: 100 µL of an aqueous dilution of the extracts is mixed in duplicate with 3.0 mL of a DPPH 'work solution in absolute methanol (100 µM.L-1), with an incubation time of 120 minutes in darkness at 37 ± 1 °C, and then absorbance is read at 517 nm against absolute methanol. The results should be expressed as ascorbic acid equivalents or Trolox equivalents in mass percentage (g% dm, dry matter) in order to facilitate comparisons. The AOC of the ethanolic extracts ranged between 12.8 and 23.1 g TE % dm and from 9.1 to 16.4 g AAE % dm. The AOC determined by the DPPH assay proposed in the present study can be related to the total polyphenolic content determined by the Folin-Ciocalteu assay.