117 resultados para prótese intraocular
Resumo:
The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .
Resumo:
OBJETIVO: Avaliar os aspectos morfológicos do comportamento de prótese de dupla face aplicada em inguinoplastia laparotômica em cães, com fixação intraperitoneal com a face de látex voltada às vísceras. MÉTODOS: Vinte cães distribuídos em dois grupos (n=10) foram submetidos à laparotomia infraumbilical com fixação da prótese de dupla face em uma região inguinal e de uma prótese controle de polipropileno contralateral. Foram pesquisados no 14° e 28° dia de pós-operatório achados macroscópicos referentes à obstrução e fístula intestinais, encistamento, incorporação e aderências. A análise microscópica envolveu o processo inflamatório e reparador. RESULTADOS: Não ocorreram processos infecciosos, obstrução ou fístula intestinal. As próteses apresentaram boa acomodação e incorporação. As aderências ocorreram em maior prevalência e intensidade com a prótese de polipropileno (p<0,05). As aderências com a borda da prótese de dupla face ocorreram em 65% na média dos grupos, sendo que, destas, 35% em média a aderência se fazia com o disco de polipropileno na face parietal. A análise dos achados microscópicos não mostrou diferença estatística entre as próteses (p>0,05). CONCLUSÃO: A prótese de dupla face na sua face parietal soma as vantagens do potencial de incorporação aos tecidos observados com o polipropileno às de biocompatibilidade do látex na sua face visceral. A pequena distância entre o disco de polipropileno e a borda da prótese de dupla face (2 cm) aliada à sua fixação com apenas cinco grampos é insuficiente para evitar que o epíploon migre em direção ao processo inflamatório desencadeado pelo polipropileno na face parietal.
Resumo:
This study aimed to compare the normal intraocular pressure (IOP) and tear secretion, by means of applanation tonometry and the Schirmer tear test-1 (STT-1), in goats of the Saanen breed with different ages, and at different time points. Thirty six goats, free of ocular abnormalities, were grouped into three different age categories (n=12), animals with 45, 180 and 549 days of age. STT-1 and IOP measurements were carried out always at 9:00am and 7:00pm, during three consecutive days. Results were evaluated statistically (P<0.05). Regarding the time of the day, overall IOP values were significantly lower at 7:00 pm (P<0.001) in individuals with 45 days of age; whereas STT-1 values were significantly higher at 7:00pm (P=0.004) in goats with 549 days of age. Considering the sum of three days, both parameters were significantly lower in individuals with 45 days of age (P<0.001). Intraocular pressure and tear secretion values increase until 180 days of age in the Saanen breed of goats.
Resumo:
The purpose of this study was to establish reference values for selected ophthalmic diagnostic tests in New Zealand rabbits (Oryctolagus cuniculus). A total of 22 adult male rabbits were used. The ophthalmic tests included evaluation of tear production with Schirmer tear test 1(STT1) and Endodontic absorbent paper point tear test (EAPPTT) using two different commercial brand materials. Applanation tonometry, Culture of the conjunctival bacterial flora, , conjunctival cytology and conjunctival histology were also performed. Mean (±SD) for STT1, EAPPTTa, EAPPTTb and IOP was 7.27±2.51mm/min, 12.43±1.69mm/min, 15.24±2.07mm/min, 12.89±2.80mm Hg, respectively. Staphylococcus epidermidis, Staphylococcus sp. and Bacillus sp. were predominant. The cytological evaluation revealed the presence columnar epithelial cells, superficial squamous keratinized cells, lymphocytes, heterophils, red blood cells, mucus and bacteria. The histological analysis revealed a stratified epithelium, characterized by the presence of columnar epithelial cells with a large number of goblet cells. The reported data can be used for therapeutic or experimental purposes.
Resumo:
The objective of this prospective study was to evaluate the efficacy and complications of the use of an intraocular sustained-release ganciclovir implant for the treatment of active cytomegalovirus (CMV) retinitis in AIDS patients. Thirty-nine eyes of 26 patients were submitted to ocular surgery. All patients underwent complete ocular examination before and after surgery. The surgical procedure was always done under local anesthesia using the same technique. The mean time for the surgical procedure was 20 min (range, 15 to 30 min). The average follow-up period was 3.7 months. Of all patient, only 4 presented recurrence of retinitis after 8, 8, 9 and 2 months, respectively. Three of them received a successful second implant. All 39 eyes of the 26 patients presented healing of retinitis as shown by clinical improvement evaluated by indirect binocular ophthalmoscopy and retinography. Retinitis healed within a period of 4 to 6 weeks in all patients, with clinical regression signs from the third week on. Six (15.4%) eyes developed retinal detachment. None of the patients developed CMV retinitis in the contralateral eye. The intraocular implant proved to be effective in controlling the progression of retinitis for a period of up to 8 months even in patients for whom systemic therapy with either ganciclovir or foscarnet or both had failed. The intraocular sustained-release ganciclovir implant proved to be a safe new procedure for the treatment of CMV retinitis, avoiding the systemic side effects caused by the intravenous medications and improving the quality of life of the patients.
Resumo:
The effects of exercise and water replacement on intraocular pressure (IOP) have not been well established. Furthermore, it is not known whether the temperature of the fluid ingested influences the IOP response. In the present study we determined the effect of water ingestion at three temperatures (10, 24 and 38ºC; 600 ml 15 min before and 240 ml 15, 30 and 45 min after the beginning of each experimental session) on the IOP of six healthy male volunteers (age = 24.0 ± 3.5 years, weight = 67.0 ± 4.8 kg, peak oxygen uptake (VO2peak) = 47.8 ± 9.1 ml kg-1 min-1). The subjects exercised until exhaustion on a cycle ergometer at a 60% VO2peak in a thermoneutral environment. IOP was measured before and after exercise and during recovery (15, 30 and 45 min) using the applanation tonometry method. Skin and rectal temperatures, heart rate and oxygen uptake were measured continuously. IOP was similar for the right eye and the left eye and increased post-water ingestion under both exercising and resting conditions (P<0.05) but did not differ between resting and exercising situations, or between the three water temperatures. Time to exhaustion was not affected by the different water temperatures. Rectal temperature, hydration status, heart rate, oxygen uptake, carbon dioxide extraction and lactate concentration were increased by exercise but were not affected by water temperature. We conclude that IOP was not affected by exercise and that water ingestion increased IOP as expected, regardless of water temperature.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
The present study aimed to study the effects of exercise training (ET) performed by rats on a 10-week high-fructose diet on metabolic, hemodynamic, and autonomic changes, as well as intraocular pressure (IOP). Male Wistar rats receiving fructose overload in drinking water (100 g/L) were concomitantly trained on a treadmill for 10 weeks (FT group) or kept sedentary (F group), and a control group (C) was kept in normal laboratory conditions. The metabolic evaluation comprised the Lee index, glycemia, and insulin tolerance test (KITT). Arterial pressure (AP) was measured directly, and systolic AP variability was performed to determine peripheral autonomic modulation. ET attenuated impaired metabolic parameters, AP, IOP, and ocular perfusion pressure (OPP) induced by fructose overload (FT vs F). The increase in peripheral sympathetic modulation in F rats, demonstrated by systolic AP variance and low frequency (LF) band (F: 37±2, 6.6±0.3 vs C: 26±3, 3.6±0.5 mmHg2), was prevented by ET (FT: 29±3, 3.4±0.7 mmHg2). Positive correlations were found between the LF band and right IOP (r=0.57, P=0.01) and left IOP (r=0.64, P=0.003). Negative correlations were noted between KITT values and right IOP (r=-0.55, P=0.01) and left IOP (r=-0.62, P=0.005). ET in rats effectively prevented metabolic abnormalities and AP and IOP increases promoted by a high-fructose diet. In addition, ocular benefits triggered by exercise training were associated with peripheral autonomic improvement.
Resumo:
A surdez profunda é uma deficiência que afeta a personalidade, o relacionamento e todo o estilo de vida do paciente. Incapacita os indivíduos de escutarem sons ambientes como sirenes e alarmes que constituem alerta em situações da vida diária e não permite a modulação vocal, tornando a voz esteticamente ruim. A prótese auditiva convencional é eficiente no tratamento de grande parte das deficiências auditivas, porém existem pacientes que não conseguem obter discriminação de palavras e sentenças mesmo com uma prótese auditiva potente. O implante coclear é a alternativa atual para estes pacientes. OBJETIVO: Avaliar o resultado auditivo dos pacientes adultos implantados com o implante coclear multicanal pelo Grupo de Implante Coclear da Disciplina de Otorrinolaringologia da Faculdade de medicina da Universidade de São Paulo. FORMA DE ESTUDO: Estudo de série. CASUÍSTICA E MÉTODO: Foram selecionados 61 pacientes com surdez profunda bilateral que utilizam o implante coclear multicanal por pelo menos seis meses e estudados os resultados auditivos através de testes de reconhecimento de palavras e sentenças. RESULTADOS: O PTA médio obtido pelos pacientes foi 38.7 dB NPS. A média em reconhecimento de sentenças em formato aberto foi de 71.3%, vogais em 86.5%, monossílabos em 52.60% e consoante medial em 52.6%. A maioria dos pacientes está apta ao uso do telefone. CONCLUSÃO: A avaliação auditiva obtida seis meses após a primeira programação do implante demonstra que pacientes de língua portuguesa obtêm excelentes resultados em testes de reconhecimento de palavras e sentenças em apresentação aberta, readquirindo uma audição útil.
Resumo:
Referimo-nos ao caso de um paciente masculino de setenta e cinco anos de idade, com um carcinoma espinocelular (SCC), que se originou na parte exterior da orelha direita há quatro anos. Sofreu uma remoção cirúrgica da parte lesionada combinada com dissecção modificada do pescoço e reconstrução com o uso de retalho peitoral maior. Além disso, teve radioterapia com 6000 rads na região temporal direita. Há dois meses o paciente mostrou urna recorrência expansiva no que diz respeito ao músculo temporal e ao osso, o osso litóide, os músculos masseter e os músculos pterigóideos, a parte direita da mandíbula, a glândula da parótida com o nervo facial, e o bulbo superior da veia jugular interna. Sofreu uma remoção cirúrgica da lesão afetada até as extremidades saudáveis e reconstrução estética e funcional com a utilização combinada de uma prótese de metal fixa do côndilo e da mandíbula direita e o uso de músculo-cutâneo trapezious flap. Apresentamos o relato de um caso sobre as opções de reconstrução que nós temos em nossos dias para proporcionar qualidade de vida a doentes que sofrem de cancro.
Resumo:
O óxido nitroso é um gás inalatório que pode aumentar a pressão intratimpânica durante o ato anestésico, bem como causar pressão negativa após sua suspensão, principalmente em pacientes com disfunção da tuba auditiva. Estas variações pressóricas podem trazer implicações clínicas, como ruptura de membrana timpânica, desarticulação da cadeia ossicular, hemotímpano, barotrauma, deslocamento de prótese de estapedotomia e lateralização do enxerto nas timpanoplastias, além da entrada de fluido seroso na orelha média durante a fase de pressão negativa. OBJETIVO: Avaliar a influência do óxido nitroso na pressão da orelha média em uma população sem disfunção tubária, realizando timpanometria no pré e pós-operatório. FORMA DE ESTUDO: Coorte transversal. MATERIAL E MÉTODO: Foi realizado um estudo prospectivo com pacientes internados no Hospital Universitário Clementino Fraga Filho - UFRJ, submetidos à anestesia geral com o uso do óxido nitroso a 50%, durante o período de abril a julho de 2003. Avaliou-se ainda se a duração da cirurgia, anestésicos associados, presença de rinite alérgica e desvio de septo nasal poderiam influenciar no aparecimento das alterações da pressão intratimpânica. RESULTADOS: A amostra constituiu-se de 50 pacientes, encontrando-se em quase metade (48%) alterações timpanométricas no pós-operatório (curva tipo C), quando comparado às de controle do pré-operatório (curva tipo A). Sexo e idade não interferiram no aparecimento das alterações timpanométricas no pós-operatório, bem como a duração da cirurgia. O tipo de anestésico volátil associado, desvio de septo nasal e rinite alérgica não exerceram influência na pressão da orelha média no pós-operatório. CONCLUSÃO: O óxido nitroso altera a pressão na orelha média tanto na fase de indução quanto na fase de resolução anestésica.
Resumo:
A audição exerce fundamental importância no desenvolvimento global da criança, porém, alguns profissionais desconhecem a contribuição que podem dar para reduzir ou minimizar as seqüelas deixadas por uma perda auditiva. OBJETIVO: Coletar dados referentes à conduta dos pediatras, de uma cidade do interior de Santa Catarina, frente à detecção precoce da deficiência auditiva e identificar a metodologia utilizada para o diagnóstico. FORMA DE ESTUDO: Coorte histórico com corte transversal. MATERIAL E MÉTODO: Análise de questionários, com dez questões abertas e nove fechadas. RESULTADOS: 62% informaram que sua formação sobre deficiência auditiva ocorreu durante a graduação; conduta nos casos de alto risco (92%) é o encaminhamento ao otorrinolaringologista; 83% referem conhecer as técnicas de avaliação, 55% afirmam desconhecer os tipos de perda auditiva, apenas 25% mencionam conhecer os graus de perda auditiva e 42% dos entrevistados acreditam que uma criança pode fazer uso da prótese auditiva antes dos seis meses. CONCLUSÃO: A necessidade de mais informações sobre a importância do diagnóstico precoce, bem como dos métodos utilizados para realização deste, mostrou-se evidente neste estudo.
Resumo:
O uso de próteses auditivas é uma boa opção para melhorar o zumbido e a perda de audição. OBJETIVO: Avaliar a resposta do zumbido à prótese retroauricular com molde aberto e com ventilação de alívio em pacientes com perda auditiva neurossensorial simétrica após um mês de uso. CASUÍSTICA E MÉTODOS: 50 pacientes atendidos no Grupo de Pesquisa em Zumbido com zumbido e perda auditiva bilateral foram submetidos a um ensaio clínico randomizado cego crossover: 26 pacientes iniciaram o ensaio utilizando molde aberto e 24 iniciaram usando ventilação de alívio. Após 30 dias de teste com o primeiro tipo de molde e um período de wash-out, o tipo de molde foi trocado e o segundo foi usado por 30 dias. O zumbido foi avaliado de modo qualitativo (melhora, inalterado e piora) e quantitativo (variação de 0 a 10 de uma escala numérica). RESULTADOS: 82% dos casos melhoraram do zumbido com pelo menos um tipo de molde e não houve diferença significante na diminuição do incômodo com o zumbido nas avaliações qualitativa e quantitativa com ambos os moldes. Entretanto 66% dos pacientes preferiram o molde aberto. CONCLUSÃO: A curto prazo, a melhora do zumbido com a prótese auditiva não depende do tamanho da ventilação do molde.
Resumo:
A cirurgia do estapédio permanece como tratamento consagrado para a otosclerose. Recentes publicações têm demonstrado que o sucesso cirúrgico nas cirurgias realizadas por médicos residentes tem diminuído e que os resultados audiológicos tem sido piores que os obtidos por cirurgiões experientes. OBJETIVOS: Avaliar a experiência do serviço de otorrinolaringologia do Hospital de Clínicas/UFPR na realização de cirurgias do estapédio no programa de residência médica. MATERIAL E MÉTODO: Estudo retrospectivo de 114 cirurgias do estapédio realizadas nos últimos 9 anos, em 96 pacientes. Os resultados audiométricos foram analisados conforme orientação do Committee on Hearing and Equilibrium e através do Amsterdam Hearing Evaluation Plots, considerando a melhora do gap pós-operatório e de limiares da via aérea. RESULTADOS: Foram incluídos 96 pacientes, na maioria adultos, do sexo feminino (67,7%) e caucasianos (93,7%). Em 50,9% dos casos foi realizada estapedectomia, sendo a grande maioria sob anestesia local e sedação (96,5%) e utilizando principalmente a prótese de Teflon (37,7%). A taxa de sucesso cirúrgico foi de 50,88%, com 11,4% de complicações. CONCLUSÃO: Os ganhos de audição pós-operatórios considerados como sucesso cirúrgico foram inferiores aos publicados na literatura por cirurgiões experientes.
Resumo:
Uma reabilitação eficiente deve reduzir os efeitos da deficiência sobre as habilidades auditivas e comunicativas do indivíduo e aumentar o bem-estar psicossocial. OBJETIVOS:Verificar a viabilidade do uso de questionários de auto-avaliação e comparar os resultados da protetização em usuários de uma instituição pública federal, com e sem queixas relacionadas às características da amplificação. MATERIAL E MÉTODOS:25 indivíduos, de 13 a 77 anos de idade, usuários de próteses auditivas. Foram aplicados os questionários de auto-avaliação HHIE-S/HHIA (Hearing Handicap Inventory for the Elderly Screening Version ou for Adult) e APHAB (Abbreviated Profile of Hearing Aid Benefit), nos indivíduos sem (Grupo 1) e com queixas relacionados às características da amplificação (Grupo 2). RESULTADOS: Diferenças significantes não foram encontradas entre os grupos nos protocolos HHIE-S/HHIA e APHAB, exceto na subescala facilidade de comunicação do APHAB, onde o Grupo 1 obteve melhor benefício. Também evidenciou-se redução significativa da incapacidade auditiva com o uso das próteses em situações favoráveis de comunicação, ambientes reverberantes e na presença de ruído ambiental para ambos os grupos. CONCLUSÃO: Os questionários revelaram ser excelentes preditores das dificuldades enfrentadas pelos usuários, e diferenças significantes foram encontradas em situações favoráveis de comunicação, onde o grupo sem queixas obteve melhor benefício.