38 resultados para normalized energy
Resumo:
This study aimed to propose methods to identify croplands cultivated with winter cereals in the northern region of Rio Grande do Sul State, Brazil. Thus, temporal profiles of Normalized Difference Vegetation Index (NDVI) from MODIS sensor, from April to December of the 2000 to 2008, were analyzed. Firstly, crop masks were elaborated by subtracting the minimum NDVI image (April to May) from the maximum NDVI image (June to October). Then, an unsupervised classification of NDVI images was carried out (Isodata), considering the crop mask areas. According to the results, crop masks allowed the identification of pixels with greatest green biomass variation. This variation might be associated or not with winter cereals areas established to grain production. The unsupervised classification generated classes in which NDVI temporal profiles were associated with water bodies, pastures, winter cereals for grain production and for soil cover. Temporal NDVI profiles of the class winter cereals for grain production were in agree with crop patterns in the region (developmental stage, management standard and sowing dates). Therefore, unsupervised classification based on crop masks allows distinguishing and monitoring winter cereal crops, which were similar in terms of morphology and phenology.
Resumo:
Modern swine production faces many challenges nowadays, among which are productivity growth, meat quality improvement, decrease of environmental damage and reduction of cost production. Pigs spend energy to vocalizing, especially when they undergo stress. The waste of energy can increase the cost of production and lead to greater environmental damage. The goal of this study was to estimate the energy spent by pigs under the stress of castration and its effect on the animals' weight gain. Two groups of ten animals each were castrated, being one group with local anesthetic and the other without anesthetic. The piglets' vocalizations were recorded during different stages of the neutering process and then estimated of the amount of energy emitted during each vocalization. Afterwards, this energy was associated with the animals' weight gain. There was no difference in the total energy spent in both groups, since the energy used during the application of anesthetic was similar to the energy spent during the castration of the animals without anesthetic. There was also no correlation between energy spent and the animals' weight gain. It was possible to estimate the amount of energy emitted through vocalization. This energy spent by piglets in pain was greater than in other handling situations (contention, weighting and realease).
Resumo:
Energy consumption in the world has been growing every year. The industrial sector represents 27.32% of the world energy demand. Heating systems that use solar energy may contribute with a percentage of the total energy required by industries. This work aimed to study the use of vacuum solar collectors for water pre-heating in boilers. We used four collectors installed according to NBR 15,569; water flow through the tubes was 0.058 L/s, and temperature in the inlet and outlet pipes was measured. Results showed that instantaneous radiation, and inlet fluid and room temperatures are variables that influence the process, reaching water maximum temperature in the solar collector outlet of 97.9 °C, and efficiency of approximately 65% for most experiments. For the financial viability evaluation, the payback study was applied, which resulted in 4; 7 and 5 years, for the respective sources: firewood, LPG (liquefied petroleum gas), and electricity. Regarding the calculation of the annual contribution to the reduction of greenhouse gases, it was, respectively, 2.162 and 356 kg of CO2 per m² of collector tubes, in comparison with firewood and LPG.
Resumo:
Citrus orchards are very important in Brazil, especially in São Paulo State, where occupy an area of 600,000 ha approximately. To identify sustainability degree of citrus production system, an energy analysis allows evaluating efficiency of direct and indirect applied inputs. Thus, this study aimed to evaluate citrus production system under energetic point of view, in which invested energy is paid back with citrus production; being compared within three scenarios for operational field efficiency. As result, by sensitivity analysis was determined that fuel was the main energy demander, followed by pesticides and fertilizers. In operational work capacity analysis, all combinations between efficiency (minimum, typical and maximum) and yield levels became positive in the seventh year, except for the combination minimum efficiency and 10 % less yield, positive in the eighth year. The best combination (maximum efficiency and 10 % more yield) has promoted investment payoff around the sixth and seventh year. By this study, it is possible to determine the total energy demand to produce citrus and indentify the applied inputs that need more attention by the decision-makers. Labor and seedlings can be ommited for further studies with citrus, since they were irrelevant. Management of agricultural machinery may pose an important role on decreasing environmental impact of citrus production.
Resumo:
ABSTRACTThe objective of this study was to determine the energy balance of the poultry-shed system and its effect on broiler performance during the production cycle. The experimental design was completely random with sub-divided blocks. The blocks were composed of five different types of sheds and the sub-blocks of the evaluation times (00:00 h to 23:00 h), allowing an analysis of variance and a comparison between means with the Tukey test. There were no significant differences between the mean values of the exchanges of sensible, latent and total heat between the poultry sheds but the differences for the evaluation times were significant (P<0.05). There was no significant difference between sheds 1 and 4 for broiler productive performance regarding weight gain, feed consumption and feed conversion. Bird performance was significant (P<0.05) for the remaining poultry sheds. The productive indexes remained below the ranges considered ideal for broilers and values in the final weeks were characterized by the poor installation efficiency in controlling temperature variations and, consequently, the energy balance in the system, which adversely affected bird productive performance.
Resumo:
ABSTRACT The present study aims to present the main concepts of the sugarcane straw to energy planning. Throughout the study, the subject is contextualized highlighting broader aspects of sustainability, which is considered the main driver towards agro-energy modernization. Concerning sugarcane straw, we first evaluated its availability regarding technical and economic aspects, and then it summarized the straw production chain for energy supply purposes. As a proposal to support agro-energy planning, it is presented some spatial tools that have been barely used in the Brazilian energy planning context so far. Therefore, working on straw to electricity associated with supply chain basis, we developed a conceptual model to spatially assess this bioenergy system. Using the model proposed, it is described the whole supply chain at state level, which accounted the potential of a single mill to explore straw, as well as main costs associated with straw acquisition, investments on the straw recovery routes and electricity transmission. Bearing these concepts in mind, it is fully believed that spatial analysis can bring important information for agro-energy action plans.
Resumo:
In early lactation dairy cattle suffer metabolic alterations caused by negative energy balance, which predisposes to fatty liver and ketosis. The aim of this study was to evaluate the metabolic condition of high yielding dairy cows subjected to three treatments for preventing severe lipomobilization and ketosis in early lactation. Fifty four multiparous Holstein cows yielding >30 L/day were divided into four groups: control (CN= no treatment), glucose precursor (PG= propylene-glycol), hepatic protector (Mp= Mercepton®), and energy supplement with salts of linolenic and linoleic faty acids (Mg-E= Megalac-E®). Treatments were administrated randomly at moment of calving until 8 weeks postpartum. Blood samples were collected on days 1, 7, 14, 21, 28, 35, 42 and 49 postpartum. Body condition score (BCS) was evaluated at the same periods and milk yield was recorded at 2nd, 4th, 5th, 6th, 7th, and 8th weeks of lactation. Concentrations of non-esterified fatty acids (NEFA), albumin, AST, ß-hydroxybutyrate (BHBA), cholesterol, glucose, total protein, urea and triglycerides were analyzed in blood samples. Cut-off points for subclinical ketosis were defined when BHBA >1.4 mmol/L and NEFA >0.7 mmol/L. General occurrence of subclinical ketosis was 24% during the period. An ascendant curve of cholesterol and glucose was observed from the 1st to the 8th week of lactation, while any tendency was observed with BHBA and NEFA, although differences among treatments were detected (p<0.05). BCS decreased from a mean of 3.85 at 1st week to 2.53 at 8th week of lactation (p=0.001). Milk yield was higher in the Mg-E group compared with the other treatment groups (p<0.05) Compared with the CN group, the treatments with Mp and PG did not show significant differences in blood biochemistry and milk yield. Cows receiving PG and Mg-E showed higher values of BHBA and NEFA (P<0.05), indicating accentuated lipomobilization. Supplementation with Mg-E also resulted in significant higher concentrations of cholesterol, BHBA, urea, AST and lower values of glycemia. This performance may be explained by the highest milk yield observed with this treatment. Treatments with PG and Mp did not improve milk yield, compared with control cows, but did not show metabolic evidence of ketosis, fat mobilization or fatty liver. These results suggest that treatment with Mg-E improves milk production but induces a higher negative energy balance leading to moderated lipomobilization and ketone bodies production, increasing the risk of fatty liver.
Resumo:
This paper presents a new strategy to control an one-legged robot aiming to reduce the energy expended by the system. To validate this algorithm, a classic method as benchmark was used. This method has been extensively validated by simulations and experimental prototypes in the literature. For simplicity reasons, the work is restricted to the two dimensional case due to simplicity reasons. This new method is compared to the classic one with respect to performance and energy expended by the system. The model consists on a springy leg, a simple body, and an actuated hinge-type hip. The new control strategy is composed of three parts, considering the hopping height, the forward speed, and the body orientation separately. The method exploits the system passive dynamics, defined as non-forced response of the system. In this case, the model is modified adding a spring to the hip. The method defines a desired leg trajectory close to the passive hip swing movement. Simulation results for both methods are analyzed and compared.