50 resultados para minimum contrast estimator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the "lactate minimum test" in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rounded atelectasis (RA) is a benign and unusual form of subpleural lung collapse that has been described mostly in asbestos-exposed workers. This form of atelectasis manifests as a lung nodule and can be confused with bronchogenic carcinoma upon conventional radiologic examination. The objective of the present study was to evaluate the variation in contrast uptake in computed tomography for the identification of asbestos-related RA in Brazil. Between January 1998 and December 2000, high-resolution computed tomography (HRCT) was performed in 1658 asbestos-exposed workers. The diagnosis was made in nine patients based on a history of prior asbestos exposure, the presence of characteristic (HRCT) findings and lesions unchanged in size over 2 years or more. In three of them the diagnosis was confirmed during surgery. The dynamic contrast enhancement study was modified to evaluate nodules and pulmonary masses. All nine patients with RA received iodide contrast according to weight. The average enhancement after iodide contrast was infused, reported as Hounsfield units (HU), increased from 62.5 ± 9.7 to 125.4 ± 20.7 (P < 0.05), with a mean enhancement of 62.5 ± 19.7 (range 40 to 89) and with a uniform dense opacification. In conclusion, in this study all patients with RA showed contrast enhancement with uniform dense opacification. The main clinical implication of this finding is that this procedure does not permit differentiation between RA and malignant pulmonary neoplasm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differentiation between stunned and infarcted myocardium in the setting of acute ischemia is challenging. Real time myocardial contrast echocardiography allows the simultaneous assessment of myocardial perfusion and function. In the present study we evaluated infarcted and stunned myocardium in an experimental model using real time myocardial contrast echocardiography. Sixteen dogs underwent 180 min of coronary occlusion followed by reperfusion (infarct model) and seven other dogs were submitted to 20 min of coronary occlusion followed by reperfusion (stunned model). Wall motion abnormality and perfusional myocardial defect areas were measured by planimetry. Risk and infarct areas were determined by tissue staining. In the infarct model, the wall motion abnormality area during coronary occlusion (5.52 ± 1.14 cm²) was larger than the perfusional myocardial defect area (3.71 ± 1.45 cm²; P < 0.001). Reperfusion resulted in maintenance of wall motion abnormality (5.45 ± 1.41 cm²; P = 0.43 versus occlusion) and reduction of perfusional myocardial defect (1.51 ± 1.29 cm²; P = 0.004 versus occlusion). Infarct size determined by contrast echocardiography correlated with tissue staining (r = 0.71; P = 0.002). In the stunned model, the wall motion abnormality area was 5.49 ± 0.68 cm² during occlusion and remained 5.1 ± 0.63 cm² after reperfusion (P = 0.07). Perfusional defect area was 2.43 ± 0.79 cm² during occlusion and was reduced to 0.2 ± 0.53 cm² after reperfusion (P = 0.04). 2,3,5-Triphenyl tetrazolium chloride staining confirmed the absence of necrotic myocardium in all dogs in the stunned model. Real time myocardial contrast echocardiography is a noninvasive technique capable of distinguishing between stunned and infarcted myocardium after acute ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When contrast sensitivity functions to Cartesian and angular gratings were compared in previous studies the peak sensitivity to angular stimuli was reported to be 0.21 log units higher. In experiments carried out to repeat this result, we used the same two-alternative forced-choice paradigm, but improved experimental control and precision by increasing contrast resolution from 8 to 12 bits, increasing the screen refresh rate from 30 Hz interlaced to 85 Hz non-interlaced, linearizing the voltage-luminance relation, modulating luminance in frequencies that minimize pixel aliasing, and improving control of the subject's exposure to the stimuli. The contrast sensitivity functions to Cartesian and angular gratings were similar in form and peak sensitivity (2.4 cycles per visual degree (c/deg) and 32 c/360º, respectively) to those reported in a previous study (3 c/deg and 32 c/360º, respectively), but peak sensitivity to angular stimuli was 0.13 log units lower than that to Cartesian stimuli. When the experiment was repeated, this time simulating the experimental control level used in the previous study, no difference between the peak sensitivity to Cartesian and angular stimuli was found. This result agrees with most current models that assume Cartesian filtering at the first visual processing stage. The discrepancy in the results is explained in part by differences in the degree of experimental control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine if radiocontrast impairs vascular relaxation of the renal artery, segments (4-5 mm in length) of canine renal artery were suspended in vitro in organ chambers to measure isometric force (95% O2/5% CO2, at 37ºC). Arterial segments with and without endothelium were placed at the optimal point of their length-tension relation and incubated with 10 µM indomethacin to prevent synthesis of endogenous prostanoids. The presence of nonionic radiocontrast (iohexol, Omnipaque 350, 1 ml in 25 ml control solution, 4% (v/v)) did not alter endothelium-dependent relaxation to acetylcholine in rings precontracted with both norepinephrine and prostaglandin F2alpha (N = 6). When the rings were precontracted with prostaglandin F2alpha, the presence of ionic contrast did not inhibit the relaxation of the arteries. However, in canine renal arteries contracted with norepinephrine, the presence of ionic radiocontrast (diatrizoate meglumine and diatrizoate sodium, MD-76, 1 ml in 25 ml control solution, 4% (v/v)) inhibited relaxation in response to acetylcholine, sodium nitroprusside (N = 6 in each group), and isoproterenol (N = 5; P < 0.05). Rings were relaxed less than 50% of norepinephrine contraction. Following removal of the contrast, vascular relaxation in response to the agonists returned to normal. These results indicate that ionic radiocontrast nonspecifically inhibits vasodilation (both cAMP-mediated and cGMP-mediated) of canine renal arteries contracted with norepinephrine. This reversible impairment of vasodilation could inhibit normal renal perfusion and act as a mechanism of renal failure following radiocontrast infusion. In the adopted experimental protocol the isoproterenol-induced relaxation of renal arteries precontracted with norepinephrine was more affected, suggesting a pivotal role of the cAMP system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360º in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresholds for young adults (N = 6; age range, 20-26 years) and older adults (N = 6; age range, 60-67 years) using the psychophysical forced-choice method. In this paradigm the volunteers had to choose the stimulus containing a test frequency at low contrast (e.g., either a sine-wave grating or an angular frequency stimulus), or another neutral stimulus at mean luminance (without any contrast). Older adults presented a loss in contrast sensitivity at high and medium angular frequencies compared to the young adults (i.e., from 8 to 96 cycles/360º). Contrary to expectation, contrast sensitivity at low angular frequencies, i.e., 2 and 4 cycles/360º, was better for the older group than for the younger group. On the other hand, contrast sensitivity for sine-wave gratings at 3 and 4 cpd was higher for young adults as expected. These results suggest age-related changes in the contrast sensitivity function for angular frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although healthy preterm infants frequently seem to be more attentive to visual stimuli and to fix on them longer than full-term infants, no difference in visual acuity has been reported compared to term infants. We evaluated the contrast sensitivity (CS) function of term (N = 5) and healthy preterm (N = 11) infants at 3 and 10 months of life using sweep-visual evoked potentials. Two spatial frequencies were studied: low (0.2 cycles per degrees, cpd) and medium (4.0 cpd). The mean contrast sensitivity (expressed in percentage of contrast) of the preterm infants at 3 months was 55.4 for the low spatial frequency (0.2 cpd) and 43.4 for the medium spatial frequency (4.0 cpd). At 10 months the low spatial CS was 52.7 and the medium spatial CS was 9.9. The results for the term infants at 3 months were 55.1 for the low spatial frequency and 34.5 for the medium spatial frequency. At 10 months the equivalent values were 54.3 and 14.4, respectively. No difference was found using the Mann-Whitney rank sum T-test between term and preterm infants for the low frequency at 3 or 10 months or for the medium spatial frequency at 3 or 10 months. The development of CS for the medium spatial frequency was equally fast for term and preterm infants. As also observed for visual acuity, CS was equivalent among term and preterm infants, suggesting that visual experience does not modify the development of the primary visual pathway. An earlier development of synapses in higher cortical visual areas of preterm infants could explain the better use of visual information observed behaviorally in these infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An assumption commonly made in the study of visual perception is that the lower the contrast threshold for a given stimulus, the more sensitive and selective will be the mechanism that processes it. On the basis of this consideration, we investigated contrast thresholds for two classes of stimuli: sine-wave gratings and radial frequency stimuli (i.e., j0 targets or stimuli modulated by spherical Bessel functions). Employing a suprathreshold summation method, we measured the selectivity of spatial and radial frequency filters using either sine-wave gratings or j0 target contrast profiles at either 1 or 4 cycles per degree of visual angle (cpd), as the test frequencies. Thus, in a forced-choice trial, observers chose between a background spatial (or radial) frequency alone and the given background stimulus plus the test frequency (1 or 4 cpd sine-wave grating or radial frequency). Contrary to our expectations, the results showed elevated thresholds (i.e., inhibition) for sine-wave gratings and decreased thresholds (i.e., summation) for radial frequencies when background and test frequencies were identical. This was true for both 1- and 4-cpd test frequencies. This finding suggests that sine-wave gratings and radial frequency stimuli are processed by different quasi-linear systems, one working at low luminance and contrast level (sine-wave gratings) and the other at high luminance and contrast levels (radial frequency stimuli). We think that this interpretation is consistent with distinct foveal only and foveal-parafoveal mechanisms involving striate and/or other higher visual areas (i.e., V2 and V4).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine contrast sensitivity curves of concentric circular patterns with radial frequencies of 0.25, 0.5, 1.0, 2.0, and 4.0 cycles per degree in young and older adult volunteers. These parameters were also compared with sensitivity contrasts for sine-wave gratings. All participants had normal acuity vision and were free of identifiable ocular illness. Contrast sensitivity was measured in 6 young adults aged 19 to 23 years and 6 older adults aged 60 to 69 years using the psychophysical forced-choice method. In this paradigm the volunteers had to decide which of two stimuli contained the above radial frequencies at low contrast levels. The other neutral stimulus was gray with homogeneous luminance. We detected a decline in contrast sensitivity for older adults at all radial frequencies compared to young adults. Also, contrast sensitivity for sine-wave gratings at all measured frequencies was better, as predicted, for all young adults. Maximum sensitivities in the radial frequency contrast sensitivity function and contrast sensitivity function occurred at 0.25 and 0.5 cycles per degree, respectively, for both young and older adults. These results suggest age-related changes in the contrast sensitivity function for concentric symmetrical stimuli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE) in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS) in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS). In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interleukin-18 (IL-18) is a cytokine that belongs to the IL-1 family. Endometriosis is strongly associated with sub-fertility, and affects about 15% of women of reproductive age. IL-18 may favor the progression of endometriosis. The objective of the present study was to determine the concentration of IL-18 in the serum and peritoneal fluid of infertile women with endometriosis. Forty infertile and 25 fertile women were screened in a teaching hospital. Thirty-four infertile patients with minimal or mild endometriosis and 22 fertile controls were enrolled in the study. The primary outcome was the estimate of IL-18 levels and the secondary outcome was the correlation between serum and peritoneal levels of IL-18. There were no differences between the two groups regarding age, body mass index and levels of peritoneal fluid IL-18 (mean ± SD): 290.85 ± 173.02 pg/mL for infertile women vs 374.21 ± 330.15 pg/mL for controls; or serum IL-18: 391.07 ± 119.71 pg/mL for infertile women vs 373.42 ± 129.11 pg/mL for controls. However, a positive association was found between serum and peritoneal IL-18 levels in patients with endometriosis: r = 0.794, P = 0.0001. All measurements were carried out at the same time by the Human IL-18 Immuno Assay ELISA kit (MBL Co. Ltd., Japan). The present study did not find evidence supporting the hypothesis that IL-18 levels are associated with infertility in women with minimal and mild endometriosis, although a positive correlation was detected in these women between peritoneal and serum levels of IL-18.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in visual function beyond high-contrast acuity are known to take place during normal aging. We determined whether sensitivity to linear sine-wave gratings and to an elementary stimulus preferentially processed in extrastriate areas could be distinctively affected by aging. We measured spatial contrast sensitivity twice for concentric polar (Bessel) and vertical linear gratings of 0.6, 2.5, 5, and 20 cycles per degree (cpd) in two age groups (20-30 and 60-70 years). All participants were free of identifiable ocular disease and had normal or corrected-to-normal visual acuity. Participants were more sensitive to Cartesian than to polar gratings in all frequencies tested, and the younger adult group was more sensitive to all stimuli tested. Significant differences between sensitivities of the two groups were found for linear (only 20 cpd; P<0.01) and polar gratings (all frequencies tested; P<0.01). The young adult group was significantly more sensitive to linear than to circular gratings in the 20 cpd frequency. The older adult group was significantly more sensitive to linear than to circular gratings in all spatial frequencies, except in the 20 cpd frequency. The results suggest that sensitivity to the two kinds of stimuli is affected differently by aging. We suggest that neural changes in the aging brain are important determinants of this difference and discuss the results according to current models of human aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess contrast sensitivity for angular frequency stimuli as well as for sine-wave gratings in adults under the effect of acute ingestion of alcohol. We measured the contrast sensitivity function (CSF) for gratings of 0.25, 1.25, 2.5, 4, 10, and 20 cycles per degree of visual angle (cpd) as well as for angular frequency stimuli of 1, 2, 4, 24, 48, and 96 cycles/360°. Twenty adults free of ocular diseases, with normal or corrected-to-normal visual acuity, and no history of alcoholism were enrolled in two experimental groups: 1) no alcohol intake (control group) and 2) alcohol ingestion (experimental group). The average concentration of alcohol in the experimental group was set to about 0.08%. We used a paradigm involving a forced-choice method. Maximum sensitivity to contrast for sine-wave gratings in the two groups occurred at 4 cpd sine-wave gratings and at 24 and 48 cycles/360° for angular frequency stimuli. Significant changes in contrast sensitivity were observed after alcohol intake compared with the control condition at spatial frequency of 4 cpd and 1, 24, and 48 cycles/360° for angular frequency stimuli. Alcohol intake seems to affect the processing of sine-wave gratings at maximum sensitivity and at the low and high frequency ends for angular frequency stimuli, both under photopic luminance conditions.