67 resultados para measurement instrument


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to present the process of construction and validation of an instrument for evaluating the care provided to people with wounds, to be used with undergraduate nursing students. METHOD Methodological study, with quantitative approach, using the Delphi technique in two rounds, the first with 30 judges and the second with 18. The analysis was made with Kappa coefficient ≥0.80, and content validity index greater than >0.80, also using the Wilcoxon test for comparison of the indices between the rounds. RESULTS It was found that of the 20 categories of the instrument, 18 presented better scores in the second Delphi round. Scores were greater in the second round in seven of the ten evaluation categories. CONCLUSION Based on the evaluation by the judges, a version of the instrument was defined with adequate indices of agreement and validity, which will be able to help in evaluating care of people with cutaneous injury given by undergraduate nursing students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To validate an instrument to assess quality of mobile emergency pre-hospital care. METHOD A methodological study where 20 professionals gave their opinions on the items of the proposed instrument. The analysis was performed using Kappa test (K) and Content Validity Index (CVI), considering K> 0.80 and CVI ≥ 0.80. RESULTS Three items were excluded from the instrument: Professional Compensation; Job Satisfaction and Services Performed. Items that obtained adequate K and CVI indexes and remained in the instrument were: ambulance conservation status; physical structure; comfort in the ambulance; availability of material resources; user/staff safety; continuous learning; safety demonstrated by the team; access; welcoming; humanization; response time; costumer privacy; guidelines on care; relationship between professionals and costumers; opportunity for costumers to make complaints and multiprofessional conjunction/actuation. CONCLUSION The instrument to assess quality of care has been validated and may contribute to the evaluation of pre-hospital care in mobile emergency services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE To describe the stages of construction and validation of an instrument in order to analyze the adherence to best care practices during labour and birth. METHOD Methodological research, carried out in three steps: construction of dimensions and items, face and content validity and semantic analysis of the items. RESULTS The face and content validity was carried out by 10 judges working in healthcare, teaching and research. Items with Content Validity Index (CVI) ≥ 0.9 were kept in full or undergone revisions as suggested by the judges. Semantic analysis, performed twice, indicated that there was no difficulty in understanding the items. CONCLUSION The instrument with three dimensions (organization of healthcare network to pregnancy and childbirth, evidence-based practices and work processes) followed the steps recommended in the literature, concluded with 50 items and total CVI of 0.98.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE Developing and validating an instrument to evaluate the playfulness of games in health education contexts. METHODOLOGY A methodological, exploratory and descriptive research, developed in two stages: 1. Application of an open questionnaire to 50 graduate students, with content analysis of the answers and calculation of Kappa coefficient for defining items; 2. Procedures for construction of scales, with content validation by judges and analysis of the consensus estimate byContent Validity Index(CVI). RESULTS 53 items regarding the restless character of the games in the dimensions of playfulness, the formative components of learning and the profiles of the players. CONCLUSION Ludicity can be assessed by validated items related to the degree of involvement, immersion and reinvention of the subjects in the game along with the dynamics and playability of the game.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to measure and analyze total rainfall (P), rainfall intensity and five-day antecedent rainfall effects on runoff (R); to compare measured and simulated R values using the Soil Conservation Service Curve Number method (CN) for each rainfall event; and to establish average R/P ratios for observed R values. A one-year (07/01/96 to 06/30/97) rainfall-runoff data study was carried out in the Capetinga watershed (962.4 ha), located at the Federal District of Brazil, 47° 52' longitude West and 15° 52' latitude South. Soils of the watershed were predominantly covered by natural vegetation. Total rainfall and runoff for the period were 1,744 and 52.5 mm, respectively, providing R/P of 3% and suggesting that watershed physical characteristics favored water infiltration into the soil. A multivariate regression analysis for 31 main rainfall-runoff events totaling 781.9 and 51.0 mm, respectively, indicated that the amount of runoff was only dependent upon rainfall volume. Simulated values of total runoff were underestimated about 15% when using CN method and an area-weighted average of the CN based on published values. On the other hand, when average values of CN were calculated for the watershed, total runoff was overestimated about 39%, suggesting that CN method shoud be used with care in areas under natural vegetation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a low-cost microprocessed instrument for in situ evaluating soil temperature profile ranging from -20.0°C to 99.9°C, and recording soil temperature data at eight depths from 2 to 128 cm. Of great importance in agriculture, soil temperature affects plant growth directly, and nutrient uptake as well as indirectly in soil water and gas flow, soil structure and nutrient availability. The developed instrument has potential applications in the soil science, when temperature monitoring is required. Results show that the instrument with its individual sensors guarantees ±0.25°C accuracy and 0.1°C resolution, making possible localized management changes within decision support systems. The instrument, based on complementary metal oxide semiconductor devices as well as thermocouples, operates in either automatic or non-automatic mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of root traits may be facilitated if they are assessed on samples of the root system. The objective of this work was to determine the sample size of the root system in order to estimate root traits of common bean (Phaseolus vulgaris L.) cultivars by digital image analysis. One plant was grown per pot and harvested at pod setting, with 64 and 16 pots corresponding to two and four cultivars in the first and second experiments, respectively. Root samples were scanned up to the completeness of the root system and the root area and length were estimated. Scanning a root sample demanded 21 minutes, and scanning the entire root system demanded 4 hours and 53 minutes. In the first experiment, root area and length estimated with two samples showed, respectively, a correlation of 0.977 and 0.860, with these traits measured in the entire root. In the second experiment, the correlation was 0.889 and 0.915. The increase in the correlation with more than two samples was negligible. The two samples corresponded to 13.4% and 16.9% of total root mass (excluding taproot and nodules) in the first and second experiments. Taproot stands for a high proportion of root mass and must be deducted on root trait estimations. Samples with nearly 15% of total root mass produce reliable root trait estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calculation of uncertainty of results represents the new paradigm in the area of the quality of measurements in laboratories. The guidance on the Expression of Uncertainty in Measurement of the ISO / International Organization for Standardization assumes that the analyst is being asked to give a parameter that characterizes the range of the values that could reasonably be associated with the result of the measurement. In practice, the uncertainty of the analytical result may arise from many possible sources: sampling, sample preparation, matrix effects, equipments, standards and reference materials, among others. This paper suggests a procedure for calculation of uncertainties components of an analytical result due to sample preparation (uncertainty of weights and volumetric equipment) and instrument analytical signal (calibration uncertainty). A numerical example is carefully explained based on measurements obtained for cadmium determination by flame atomic absorption spectrophotometry. Results obtained for components of total uncertainty showed that the main contribution to the analytical result was the calibration procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the evolution of temperature measurement in the last four centuries using thermometers based on the thermal expansion of liquids such as ethyl alcohol and mercury. The concept of temperature was strongly dependent on the researcher and there was no systematic temperature scale for universal use. The precursor of the common thermometer was the thermoscope, probably invented at the end of the XVIth century. In the XVIIIth century the instrument was greatly improved and several thermometric scales were proposed some of which have been in use until now. These scales were based on arbitrary points. Mercury and ethyl alcohol were the most employed thermometric fluids. In the XIXth century, the concept of absolute zero was a great advance in this field. The most important contribution during the XXth century was the establishment of international temperature scales. The design of the thermometer has been essentially the same along the last 300 years, but many models were proposed for industrial and research purposes. Its association with the densimeter was of great importance for control of industrial chemical processes and also for teaching purposes in the past. Nowadays, there is a clear tendency to replace mercury-based thermometers by electronic digital models. Thermochemistry is the natural relationship between temperature and chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar radiation is an important factor for plant growth, being its availability to understory crops strongly modified by trees in an Agroforestry System (AFS). Coffee trees (Coffea arabica - cv. Obatã IAC 1669-20) were planted at a 3.4 x 0.9 m spacing inside and aside rows of monocrops of 12 year-old rubber trees (Hevea spp.), in Piracicaba-SP, Brazil (22º42'30" S, 47º38'00" W - altitude: 546m). One-year-old coffee plants exposed to 25; 30; 35; 40; 45; 80; 90; 95 and 100% of the total solar radiation were evaluated according to its biophysical parameters of solar radiation interception and capture. The Goudriaan (1977) adapted by Bernardes et al. (1998) model for radiation attenuation fit well to the measured data. Coffee plants tolerate a decrease in solar radiation availability to 50% without undergoing a reduction on growth and LAI, which was approximately 2m².m-2 under this condition. Further reductions on the availability of solar radiation caused a reduction in LAI (1.5m².m-2), thus poor land cover and solar radiation interception, resulting in growth reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new methodologies and tools that enable to determine the water content in soil is of fundamental importance to the practice of irrigation. The objective of this study was to evaluate soil matric potential using mercury tensiometer and puncture digital tensiometer, and to compare the gravimetric soil moisture values obtained by tensiometric system with gravimetric soil moisture obtained by neutron attenuation technique. Four experimental plots were maintained with different soil moisture by irrigation. Three repetitions of each type of tensiometer were installed at 0.20 m depth. Based on the soil matric potential and the soil water retention curve, the corresponding gravimetric soil moisture was determined. The data was then compared to those obtained by neutron attenuation technique. The results showed that both tensiometric methods showed no difference under soil matric potential higher than -40 kPa. However, under drier soil, when the water was replaced by irrigation, the soil matric potential of the puncture digital tensiometer was less than those of the mercury tensiometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate genes differentially expressed in ovaries from lean (wild type) and obese (ob/ob) female mice and cyclic AMP production in both groups.METHODS: The expression on messenger RNA levels of 84 genes concerning obesity was analyzed through the PCR array, and cyclic AMP was quantified by the enzyme immunoassay method.RESULTS: The most downregulated genes in the Obesity Group included adenylate cyclase-activating polypeptide type 1, somatostatin, apolipoprotein A4, pancreatic colipase, and interleukin-1 beta. The mean decrease in expression levels of these genes was around 96, 40, 9, 4.2 and 3.6-fold, respectively. On the other hand, the most upregulated genes in the Obesity Group were receptor (calcitonin) activity-modifying protein 3, peroxisome proliferator activated receptor alpha, calcitonin receptor, and corticotropin-releasing hormone receptor 1. The increase means in the expression levels of such genes were 2.3, 2.7, 4.8 and 6.3-fold, respectively. The ovarian cyclic AMP production was significantly higher in ob/ob female mice (2,229±52 fMol) compared to the Control Group (1,814±45 fMol).CONCLUSIONS: Obese and anovulatory female mice have reduced reproductive hormone levels and altered ovogenesis. Several genes have their expression levels altered when leptin is absent, especially adenylate cyclase-activating polypeptide type 1.