121 resultados para mapping technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the performance of an in-house nested-PCR system for the detection of the Mycobacterium tuberculosis complex in pleural fluid, blood and urine samples from pleural effusion tuberculosis patients by health services physicians in Pernambuco, Brazil. Methods A prospective double-blind study with 37 hospitalized patients of both sexes, aged over 15, was used to investigate the diagnosis of pleural effusion. The criteria used to define the cases included the demonstration of bacillus in biological samples by smear or culture or by a granulomatous finding in the histopathological examination, associated with an evident response to specific treatments to each clinical situation. Pleural fluid, blood and urine samples were collected and subjected to routine tests and the nested PCR technique to assess for M. tuberculosis amplification. Results In total, 37 pleural effusion patients took part in the study, of whom 19 (51.3%) had tubercular etiologies and 18 (48.7%) had etiologies from other causes. When the pleural fluid, blood and/or urine sample in-house nested-PCR sensitivities were evaluated simultaneously, the results were positive regardless of the biological specimen (the sensitivity was 84.2%); however, when the blood and/or urine samples were analyzed together, the sensitivity was 72.2%. When the pleural fluid samples were evaluated alone, the sensitivity was only 33.3%. Conclusions The performance of the diagnostic pleural tuberculosis nested-PCR was directly related to the diversity of the samples collected from the same patient. Additionally, this study may identify a need to prioritize non-invasive blood and urine collection for this diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors analysed a series of 22 patients undergoing surgical correction of congenital hand syndactyly by the rectangular flap technique. Using our evaluation method, we found that good functional and aesthetic results were obtained in 77.3% of the patients, with a complication rate of 13.6%. We concluded that the rectangular flap technique has a simple design, is easily reproducible by in-training staff, has good results, and can be applied on the majority of the syndactyly cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study electrophysiological characteristics that enable the identification and ablation of sites of chagasic tachycardia. METHODS: Thirty-one patients with chronic Chagas' heart disease and sustained ventricular tachycardia (SVT) underwent electrophysiological study to map and ablate that arrhythmia. Fifteen patients had hemodinamically stable SVT reproducible by programmed ventricular stimulation, 9 men and 6 women with ages ranging from 37 to 67 years and ejection fraction varying from 0.17 to 0.64. Endocardial mapping was performed during SVT in all patients. Radiofrequency (RF) current was applied to sites of presystolic activity of at least 30 ms. Entrainment was used to identify reentrant circuits. In both successful and unsuccessful sites of RF current application, electrogram and entrainment were analyzed. RESULTS: Entrainment was obtained during all mapped SVT. In 70.5% of the sites we observed concealed entrainment and ventricular tachycardia termination in the first 15 seconds of RF current application. In the unsuccessful sites, significantly earlier electrical activity was seen than in the successful ones. Concealed entrainment was significantly associated with ventricular tachycardia termination. Bystander areas were not observed. CONCLUSION: The reentrant mechanism was responsible for the genesis of all tachycardias. In 70.5% of the studied sites, the endocardial participation of the slow conducting zone of reentrant circuits was shown. Concealed entrainment was the main electrophysiological parameter associated with successful RF current application. There was no electrophysiological evidence of bystander regions in the mapped circuits of SVT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare immediate and late results in patients with or without fenestration who underwent cavopulmonary anastomosis so that we could assess the efficiency of the technique. METHODS: Sixty-two patients underwent surgery between 1988 and 1999, 41 with fenestration (group I -G I) and 21 without fenestration (group II -G II). Tricuspid atresia was prevalent in group I (23-56%) and single ventricle was prevalent in group II (14-66%). Mean ages at the time of operation were 7.3 years in group I and 7.6 in group II. At late follow-up, mean ages were 10.6 years in group I and 12.8 years in group II. RESULTS: Immediate and late mortality were 7.3% in G-I and 4.7% in G-II. Significant pleural effusion occurred in 41.4% of G-I patients and in 23.8% of G-II patients. Significant pericardial effusion occurred in 29.2% and 14.2%, respectively, in groups I and II. Central venous pressure was greater in G-II, 17.7 cm in H2O, as opposed to 15 cm in G-I. Hospital stay was similar between the groups, 26.3 and 21.8 days, respectively. Cyanosis and arterial insaturation occurred in 5 patients, and 4 patients were in functional class II, all from G-I. At late follow-up, 58 (93.5%) were in functional class I. Sinus rhythm was present in 94%, and pulmonary perfusion was similar in both groups. Eleven patients who underwent spirometry had good tolerance to physical effort. CONCLUSION: Atrial fenestration did not improve the immediate or late follow-up of patients who underwent cavopulmonary anastomosis, and is, therefore, dispensable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study changes in survival, in biological activities and behavior of planorbids submitted to increased hydrostatic pressure, we developed a technique using two transparent chambers and a hydraulic piston. The apparatus permitted renewal of the liquid medium without substantial variations in pressure, thus eliminating excretion products and maintaining the desired O2 level and thereby permitting us to evaluate the effects of pressure independently of the occurrence of anoxia. Pressure was maintained without any contact of the liquid medium with compressed air, a situation which reproduced with relative fidelity what occurs in nature and assured the presence of the same amounts of gases in the two observation chambers (Control and Experimental). Biomphalaria glabrata was found to be able to survive at least 48 hours when submitted to 49.02 x 10**4 Pa (equivalent to a water depth of 48.8 m), continuing to day egg masses and showing few behavioral changes when compared with the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular karyotypes for 20 reference strais of species complexes of Leishmania were determined by contour-clamped homogeneous eletric field (CHEF) electrosphoresis. Determination of number/position of chromosome-sized bands and chromosomal DNA locations of house-keeping genes were the two criteria used for differentiating and classifying the Leishmania species. We have established two gel running conditions of optimal separation of chromosomes, wich resolved DNA molecules as large as 2,500 kilobase pairs (kb). Chromosomes were polymorphic in number (22-30) and size (200-2,500 kb) of bands among members of five complexes of Leishmania. Although each stock had a distinct karyotype, in general the differences found between strains and/or species within each complex were not clear enough for parasite identification. However, each group showed a specific number of size-concordant DNA molecules, wich allowed distinction among the Leishmania complex parasites. Clear differences between the Old and New world groups of parasites or among some New World Leishmania species were also apparent in relation to the chromosome locations of beta-tubulin genes. Based on these results as well as data from other published studies the potencial of using DNA karyotype for identifying and classifying leishmanial field isolates is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using improved pulsed field gel electrophoresis conditions, the molecular karyotype of the reference clone CL Brener selected for Trypanosoma cruzi genome project was established. A total of 20 uniform chromosomal bands ranging in size from 0.45 to 3.5 Megabase pairs (Mbp) were resolved in a single run. The weighted sum of the chromosomal bands was approximately 87 Mbp. Chromoblots were hybridized with 39 different homologous probes, 13 of which identified single chromosomes. Several markers showed linkage and four different linkage groups were identified, each comprising two markers. Densitometric analysis suggests that most of the chromosomal bands contain two or more chromosomes representing either homologous chromosomes and/or heterologous chromosomes with similar sizes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Worm burdens recovered from inbred mice strains, namely C57Bl/6, C57Bl/10, CBA, BALB/c, DBA/2 and C3H/He, conventionally maintained in two institutional animal houses in the State of Rio de Janeiro, RJ, Brazil, were analyzed and compared, regarding their prevalences and mean intensities.Three parasite species were observed: the nematodes Aspiculuris tetraptera, Syphacia obvelata and the cestode Vampirolepis nana. A modification of the anal swab technique is also proposed for the first time as an auxiliary tool for the detection of oxyurid eggs in mice