339 resultados para landmine detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histopathological and ultrastructural studies of 23 patients who died with clinical diagnosis of measles were carried out. In 12 cases viral nucleocapsids were searched by electron microscopy and detected in 100% of the cases in the lungs and in 50% of the cases in the central nervous system. They were mostly intranuclear. Histopathological changes associated to neurological alterations and the detection of virion are discussed in relation to acute and delayed clinical manifestations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty purulent cerebrospinal fluid (CSF) samples from patients with clinical evidence of meningitis were studied using the Directigen latex agglutination (LA) kit to determine the presence of bacterial antigen in CSF. The results showed a better diagnostic performance of the LA test than bacterioscopy by Gram stain, culture and counterimmunoelectrophoresis (CIE), as far as Neisseria meningitidis groups B and C, and Haemophilus influenzae type b are concerned, and a better performance than bacterioscopy and culture considering Streptococcus pneumoniae. Comparison of the results with those of culture showed that the LA test had the highest sensitivity for the Neisseria meningitidis group C. Comparing the results with those of CIE, the highest levels of sensitivity were detected for N. meningitidis groups B and C. Regarding specificity, fair values were obtained for all organisms tested. The degree of K agreement when the LA test was compared with CIE exhibited better K indices of agreement for N. meningitidis groups B and C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ORF strain of Cysticercus longicollis represents an important model for the study of heterologous antigens in the immunodiagnosis of neurocysticercosis (NC). The immunoperoxidase (IP) technique was standardized using a particulate antigen suspension of Cysticercus longicollis (Cl) and Cysticercus cellulosae (Cc). Cerebrospinal fluid (CSF) samples were incubated on the antigen fixed to microscopy slides; the conjugate employed was anti-IgG-peroxidase and the enzymatic reaction was started by covering the slides with chromogen solution (diaminobenzidine/H2O2). After washing with distilled water, the slide was stained with 2% malachite green in water. Of the CSF samples from 21 patients with NC, 19 (90.5%) were positive, whereas the 8 CSF samples from the control group (100%) were negative. The results of the IP-Cl test applied to 127 CSF samples from patients with suspected NC showed 28.3% reactivity as opposed to 29.1 % for the IP-Cc test. The agreement index for the IP test (Cl x Cc) was 94.2%, with no significant difference between the two antigens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-ELISA was developed for the detection of antibodies in CSF in the immunologic diagnosis of human neurocysticercosis, using antigen extracts of the membrane and scolex of Cysticercus cellulosae (M+S-Cc) and, alternately, membrane (M) and vesicular fluid (VF) of Cysticercus longicollis (Cl) covalently bound to a new solid phase consisting of polyester fabric treated with N-methylol-acrylamide resin (dot-RT). The test was performed at room temperature, with reduced incubation times and with no need for special care in the manipulation of the support. The sensitivity rates obtained were 95.1% for antigen Cc and 97.6% for antigen Cl. Specificity was 90.6% when Cc was used, and 96.9% and 100% when M-Cl and VF-Cl were used, respectively. No significant differences in titer were observed between tests carried out with homologous and heterologous antigens. The low cost and easy execution of the dot-RT test using antigen extracts of Cysticercus longicollis indicate the test for use in the immunodiagnosis of human neurocysticercosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to determine the prevalence of certain mycoplasma species, i.e., Mycoplasma hominis, Ureaplasma urealyticum and Mycoplasma penetrans, in urethral swabs from HIV-1 infected patients compared to swabs from a control group. Mycoplasmas were detected by routine culture techniques and by the Polymerase Chain Reaction (PCR) technique, using 16SrRNA generic primers of conserved region and Mycoplasma penetrans specific primers. The positivity rates obtained with the two methods were comparable. Nevertheless, PCR was more sensitive, while the culture techniques allowed the quantification of the isolates. The results showed no significant difference (p < 0.05) in positivity rates between the methods used for mycoplasma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a case of human T-lymphotropic virus type I associated myelopathy in a 50-year old woman in Nigeria. The patient presented with progressive loss of tone to the two lower limbs and later inability to walk. The HTLV-I antibody presence in the plasma collected from the patient was repeatedly detected by enzyme immunoassays (Abbott HTLV-I EIA and Coulter SELECT-HTLV I/II) and confirmed by Western blot technique. In addition, HTLV-I DNA was amplified from the genomic DNA isolated from the peripheral blood mononuclear cells of the patient by the polymerase chain reaction technique. This finding is significant being the first report of association of HTLV-I with myelopathy in Nigeria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a period of 2 years, five follow-up measures of prevalence and incidence rates were estimated in a prospective study of S. mansoni infection in a group of schoolchildren who were living in a rural area of the Municipality of Itariri (São Paulo, Brazil), where schistosomiasis is transmitted by Biomphalaria tenagophila. Infection was determined by the examination of three Kato-Katz stool slides, and the parasitological findings were analyzed in comparison to serological data. In the five surveys, carried out at 6-month intervals (March-April and September-October), the prevalences were, respectively, 8.6, 6.8, 9.9, 5.8 and 17.2% by the Kato-Katz, and 56.5, 52.6, 60.8, 53.5 and 70.1% by the immunofluorescence test (IFT). Geometric mean egg counts were low: 57.8, 33.0, 35.6, 47.3 and 40.9 eggs per gram of feces, respectively. Of the total of 299 schoolchildren, who submitted five blood samples at 6-month intervals, one for each survey, 40% were IFT-positive throughout the study, and 22% were IFT-negative in all five surveys. Seroconversion from IFT negative to positive, indicating newly acquired S. mansoni infection, was observed more frequently in surveys carried out during March-April (after Summer holidays), than during September-October. Seasonal trends were not statistically significant for detection of S. mansoni eggs in stool. The results indicate that the use of IgM-IFT is superior to parasitological methods for detection of incidence of S. mansoni infection in areas with low worm burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previously healthy seven-year-old boy was admitted to the intensive care unit because of toxaemia associated with varicella. He rapidly developed shock and multisystem organ failure associated with the appearance of a deep-seated soft tissue infection and, despite aggressive treatment, died on hospital day 4. An M-non-typable, spe A and spe B positive Group A Streptococcus was cultured from a deep soft tissue aspirate. The criteria for defining Streptococcal toxic shock-like syndrome were fulfilled. The authors discuss the clinical and pathophysiological aspects of this disease as well as some unusual clinical findings related to this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is known that fecal examination to detect Giardia lamblia cysts or trophozoites produces a high percentage of false-negative results. A commercially available immunoenzymatic assay (ProSpecT Giardia Microplate Assay, Alexon, Inc., BIOBRÁS) to detect G. lamblia specific coproantigen was evaluated for the first time in Brazil. A total of 90 specimens were tested. Each specimen was first tested as unpreserved stool, and then it was preserved in 10% Formalin to be tested 2 months later. The assay was able to identify all the 30 positive patients (sensitivity = 100.0%) by visual or spectrophotometric examination in the unpreserved specimens and was negative in 57 of the 60 patients without G. lamblia (specificity = 95.0%). The assay identified 27 of the 30 positive patients (sensitivity = 90.0%) and was negative in 59 of the 60 negatives (specificity = 98.3%) in the preserved stools according to both readings. A marked difference was observed in the optical densities in both groups, preserved and unpreserved stools, when the G. lamblia-positive specimens were compared to the negative or positive for other intestinal parasites than G. lamblia. The assay seems a good alternative for giardiasis diagnosis, especially when the fecal examination was repeatedly negative and the patient presents giardiasislike symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.