39 resultados para ionic liquid–solvent


Relevância:

10.00% 10.00%

Publicador:

Resumo:

European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methylmercury is the most hazardous mercury species known. Due to its high stability, lipid solubility, and ionic properties, this compound shows a high ability to cross membranes in living organisms, damaging the central nervous system, mainly the brain, and the effects of chronic poisoning are progressive. In this paper some aspects related to the toxicity and the cases of methylmercury poisoning are described. Other aspects related to the behavior of methylmercury and the environmental factors that influence the transformation of mercury in the water and sediment, with emphasis on the methylation/demethylation reactions and the mercury cycle are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study the factors that affect the extraction of pesticide residues from water samples for their determination by solid-phase micro-extraction (SPME) and GC/MS were optimized. The fiber polymer, the extraction mode, the ionic strength, the stirring rate, the pH and the extraction time were the most significant parameters evaluated. The recovery obtained with the proposed method ranged from 94 to 110% and the sensitivity of the method, determined by calculating the detection limit (DL), ranged from 0.004 to 0.1 mug l-1. The results obtained with spiked real samples, at the 0.1 mug l-1 level, showed acceptable conformity with the expected values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemical composition of rainwater samples collected from March 2002 to February 2003 in downtown São Paulo city (Universidade Presbiteriana Mackenzie) is presented. Potentiometric and conductimetric measurements were used to evaluate the [H+] and the total ionic content. Major anions and cations were determined by ion chromatography with conductivity detection. The rainwater was acidic with a mean pH of 4.99. The volume weighted means, VWM, of the anions nitrate, acetate and sulfate were, respectively, 21.2, 16.9 and 12.4 µmol L-1. Ammonium was the most abundant ion with a VWM of 37.6 µmol L-1. The contribution of each anion to the free acidity potential decreases in the following order: SO4(2-) (28.8%), CH3COO- (24.7%), NO3- (22.8%), Cl- (13.4%), HCOO- (7.7%) and C2O4(2-) (2.5%). The relative contribution of the weak organic acids to the free acidity was significant, 34.9%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Mössbauer analysis along with the structural Rietveld refinement based on powder X-ray data for the magnetic fraction (saturation magnetization, sigma = 19 J T-1 kg-1) separated from a tuffite material from Alto Paranaíba, state of Minas Gerais, Brazil, reveal that a (Ti, Mg)-rich maghemite (deduced sigma = 17 J T-1 kg-1) and, for the first time observed in this lithodomain, magnesioferrite (characteristic sigma = 21 J T-1 kg-1) respond for the magnetization of the rock material. Consistent models for the ionic distribution in these iron-rich spinel structures are proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The alpha-zirconium (IV) hydrogenphosphate (alpha-ZrP) has received great attention in the last years due to its properties like ion exchange, intercalation, ionic conductivity and catalytic activity. This work reports a method to produce metallic copper clusters on alpha-ZrP to be used as catalysts in petrochemical processes. It was found that the solids were non-crystalline regardless of the uptake of copper and the reduction. The specific surface area increased as a consequence of the increase of the interlayer distance to accept the copper ions between the layers. During the reduction, big clusters of copper (0,5-11µ) with different sizes and shapes were produced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wet (n = 21) and dry (n = 23) deposition samples were collected from March to September 2002 at the southern coast of Ilha Grande. Rainwater pH varied from 4.3 to 6.3 and ionic concentrations (in µmol L-1) decreased in the order Cl- > Na+ > Mg2+ > SO4(2-) > NO3- ~ NH4+ > K+ ~ H+ > Ca2+. Scavenging of sea-salt aerosols was the major source of Cl-, Na+, Mg2+, and Ca2+. Half of total SO4(2-) was non-sea-salt SO4(2-). Total deposition fluxes of NH4+, NO3-, and non-sea-salt SO4(2-) were respectively 9.3, 17.8, and 16.0 mol ha-1 month-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experiment is proposed that can be included in undergraduate courses of chemistry. The subject is the acidity of organic compounds, which are employed as pH indicators, particularly in acid-base titrations. The indicators used are methyl orange, bromophenol blue and bromocresol green in aqueous medium. The influence of colloidal systems on the equilibrium is evaluated by the pKa. The colloids employed are surfactants like sodium dodecyl sulfate, cetyl-trimethylammonium bromide and a polymeric non-ionic F127 (pluronics). The effect of stabilization promoted by the system on the acidic or basic structureof the indicator establishes the action mechanism of the colloid on the pKa values.