121 resultados para field efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACTThis paper analyzes the changes in the total factor productivity index of a Spanish hotel chain in the period from 2007 to 2010 with the purpose of identifying efficiency patterns for the chain in a period of financial crisis. The data envelopment analysis (DEA) Malmquist productivity index was used to estimate productivity change in 38 hotels of the AC chain. Results reveal AC hotels' efficiency trends and, therefore, their competitiveness in the recession period; they also show the changes experienced in these hotels' total productivity and its components: technological and efficiency changes. Positive efficiency changes were due to positive technical efficiency rather than technological efficiency. The recession period certainly influenced the performance of AC Hotels, which focused on organizational changes rather than investing in technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Cyclopid copepods are known to be good mosquito controllers, specially as regards the larvae of the dengue vectors Aedes aegypti and Ae. albopictus. MATERIAL AND METHOD: The objective of the study was to survey the local copepod fauna and search for new strains of M. longisetus var. longisetus, comparing the potential of the samples found with the current strain ML-01 against Ae. albopictus larvae, under laboratory conditions. Eleven bodies of water in Campinas, SP, Brazil, were screened for copepods by collecting 1.5 l of water from each of then. The predatory potential of adults copepods was evaluated over 24 h, in the laboratory, for groups of 5 individuals preying upon 30 first instar Ae. albopictus larvae. RESULTS AND CONCLUSION: The following cyclopid species were found: Metacyclops mendocinus, Tropocyclops prasinus, Eucyclops sp, Eucyclops serrulatus, Eucyclops solitarius, Eucyclops ensifer, Macrocyclops albidus var. albidus and Mesocyclops longisetus var. longisetus. The predatory potential of these copepods ranged from nil to 97.3%. A sample collected in the field containing only M. longisetus var. longisetus showed the best control efficiency with no significant difference from a three-year old laboratory culture (ML-01) of the same species evaluated for comparison. The sample with few M. albidus var. albidus was ranked in second place showing an average 25.9% efficiency. The use of copepods in trap tires as dengue vector controllers is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The Integrated Management of Childhood Illness is a strategy designed to address major causes of child mortality. The aim of this study was to assess the impact of the strategy on the quality of child health care provided at primary facilities. METHODS: Child health quality of care and costs were compared in four states in Northeastern Brazil, in 2001. There were studied 48 health facilities considered to have had stable strategy implementation at least two years before the start of study, with 48 matched comparison facilities in the same states. A single measure of correct management of sick children was used to assess care provided to all sick children. Costs included all resources at the national, state, local and facility levels associated with child health care. RESULTS: Facilities providing strategy-based care had significantly better management of sick children at no additional cost to municipalities relative to the comparison municipalities. At strategy facilities 72% of children were correctly managed compared with 56% in comparison facilities (p=0.001). The cost per child managed correctly was US$13.20 versus US$21.05 in the strategy and comparison municipalities, respectively, after standardization for population size. CONCLUSIONS: The strategy improves the efficiency of primary facilities in Northeastern Brazil. It leads to better health outcomes at no extra cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

E. coli was submitted to a 5G electromagnetic field generated by a alternate 60 Hz voltage source. The differences on growth and glucose consume in control and exposed groups were evaluated using the non-parametric Mann-Whitney U-test. There was a significant difference in glucose consume and growth in E. coli after 8 hours of exposition to electromagnetic field. It can be concluded that electromagnetic field had a positive effect in consume of glucose and growth of E. coli. The cause of these results can be explained by an increasing of glucose entrance through membrane due to the stimulated transport system via Facility Diffusion or cyclotron resonance. The growth can be caused by shortening of lag phase and excitement of log phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Persistence of Bacillus thuringiensis var. israelensis (Vectobac WDG) and methoprene (Metoprag S-2G) was evaluated against Aedes aegypti late third instar larvae of the Rockefeller strain in a semi-field bioassay. Tests were performed in Rio de Janeiro, using containers made of plastic, iron, concrete and asbestos, placed in a shaded area. The formulations used were 0.2 g of Vectobac-WDG and 1g of Metoprag S-2G per 100 liters of water in house storage containers. Vectobac WDG was tested twice, in March and in April/May, 2002. In March (temperature ranging from 21.5 to 39.3 ºC), 70-100% mortality was observed by the 7th day and declined abruptly thereafter. No significant differences were observed among the container types. In April/May (18.6 to 34.8 ºC) mortality was higher than 70% to 30-36 days in all cases, except in the iron container (40% mortality on the 12th day). Metoprag S-2G was evaluated in April/May, 2002, and induced mortality higher than 70% up to 15 days in the plastic and iron containers and only seven days in the concrete container. In the asbestos container, maximal mortality was achieved on day one post-treatment (66%). Our results point to a low persistence of both formulations in the weather conditions of Rio de Janeiro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.