93 resultados para fast sample preparation method
Resumo:
Considering the possibility that pesticides used in cattle raising produce residues in milk and cause harm to public health, this study developed a multiresidue method for determination of pesticide residues in bovine milk, using a modified QuEChERS method for sample preparation, and quantification by GC-MS/MS. The method proved to be efficient, resulting in satisfactory recoveries in the range 71.1 to 117.4%, for 45 of the 48 compounds analyzed with RSD values < 17.3%. The method LOD and LOQ were3.0 and 10.0 µg L-1, respectively, except for cyfluthrin which showed 7.5 and 25.0 µg L-1.
Resumo:
In this research, scanometry was used as a new, simple, fast and inexpensive method for a colorimetric determination of Mn2+ ion in water samples and thermocouple wire through the use of periodate reagent in an acidic medium. The results showed the oxidization of colorless Mn2+ ion by periodate and the formation of a purplish MnO4- ion. The system had a linear range of 1.0 to 70.0 µg mL-1 Mn2+ ion with a detection limit of 0.314 µg mL-1 and a relative standard deviation of 2.77% for G color value. This method has the capability to determine low levels of Mn2+ ion in thermocouple wire and water samples.
Resumo:
This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 ºC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.
Resumo:
Serological techniques are of great importance for plant virus identification and characterization. The major limiting factor for using these techniques for plant virus identification is the requirement of a good virus purified preparation to be used in immunizing animals for antiserum production. In the present study, two New Zealand rabbits were orally immunized with extracts from cowpea (Vigna unguiculata) plants systemically infected with Cowpea severe mosaic virus (CPSMV) and with extracts from papaya (Carica papaya) infected with Papaya lethal yellowing virus (PLYV). The leaf extracts were prepared in saline solution 0.15 M in the rate of 1:1 (w/v) and clarified by a centrifugation of 10,000 g for 10 min. The clarified extracts containing the viruses were orally administered to the New Zealand rabbits in two series of five daily doses of 1.0 ml each. The obtained policlonal antisera were shown to be very specific to their respective viruses in double immunodiffusion and indirect ELISA. These seem to be the first antisera specific for plant virus obtained by rabbit oral immunization. The results open up some possibilities for producing antisera to plant viruses of difficult purification. It is a simple, fast and inexpensive method for production of antisera for plant viruses when compared to the traditional techniques that involve rabbit injections with purified virus preparations.
Resumo:
A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.
Resumo:
An in house indirect immmunofluorescence assay ( IFA ) in relation to neutralization (NT) reference test, was assessed as a fast and cheap method to carry out serological surveys for St. Louis Encephalitis virus (SLE). Sera obtained from 213 blood donors were analyzed by both tests. The prevalence of seropositivity obtained with IFA was lower than (30.98%) that observed on NT (41.78%). The relative specificity rate of IFA was 96.77% whereas its relative sensitivity rate was 69.66%. Kappa index showed a good correlation between both tests. The results indicate that neutralization assay is still the serological test with the highest sensitivity and specificity relative rates for detecting antibodies against SLE virus. Nevertheless, the IFA could be useful as an alternative test in order to learn the circulation of the Flavivirus genus in a certain area.
Resumo:
New methodologies were developed for the identification of Nocardia but the initial diagnosis still requires a fast and accurate method, mainly due to the similarity to Mycobacterium, both clinical and bacteriologically. Growth on Löwenstein-Jensen (LJ) medium, presence of acid-fast bacilli through Ziehl-Neelsen staining, and colony morphology can be confusing aspects between Nocardia and Mycobacterium. This study describes the occurrence of Nocardia spp. in a mycobacterial-reference laboratory, observing the main difficulties in differentiating Nocardia spp. from Mycobacterium spp., and correlating isolates with nocardiosis cases. Laboratory records for the period between 2008 and 2012 were analyzed, and the isolates identified as Nocardia sp. or as non-acid-fast filamentous bacilli were selected. Epidemiological and bacteriological data were analyzed as well. Thirty-three isolates identified as Nocardia sp. and 22 as non-acid-fast bacilli were selected for this study, and represented 0.12% of isolates during the study period. The presumptive identification was based on macroscopic and microscopic morphology, resistance to lysozyme and restriction profiles using the PRA-hsp65 method. Nocardia spp. can grow on media for mycobacteria isolation (LJ and BBL MGIT™) and microscopy and colony morphology are very similar to some mycobacteria species. Seventeen patients (54.8%) were reported and treated for tuberculosis, but presented signs and symptoms of nocardiosis. It was concluded that the occurrence of Nocardia sp. during the study period was 0.12%. Isolates with characteristics of filamentous bacilli, forming aerial hyphae, with colonies that may be pigmented, rough and without the BstEII digestion pattern in PRA-hsp65 method are suggestive of Nocardia spp. For a mycobacterial routine laboratory, a flow for the presumptive identification of Nocardia is essential, allowing the use of more accurate techniques for the correct identification, proper treatment and better quality of life for patients.
Resumo:
Introduction Polymerase chain reaction (PCR) may offer an alternative diagnostic option when clinical signs and symptoms suggest visceral leishmaniasis (VL) but microscopic scanning and serological tests provide negative results. PCR using urine is sensitive enough to diagnose human visceral leishmaniasis (VL). However, DNA quality is a crucial factor for successful amplification. Methods A comparative performance evaluation of DNA extraction methods from the urine of patients with VL using two commercially available extraction kits and two phenol-chloroform protocols was conducted to determine which method produces the highest quality DNA suitable for PCR amplification, as well as the most sensitive, fast and inexpensive method. All commercially available kits were able to shorten the duration of DNA extraction. Results With regard to detection limits, both phenol: chloroform extraction and the QIAamp DNA Mini Kit provided good results (0.1 pg of DNA) for the extraction of DNA from a parasite smaller than Leishmania (Leishmania) infantum (< 100fg of DNA). However, among 11 urine samples from subjects with VL, better performance was achieved with the phenol:chloroform method (8/11) relative to the QIAamp DNA Mini Kit (4/11), with a greater number of positive samples detected at a lower cost using PCR. Conclusion Our results demonstrate that phenol:chloroform with an ethanol precipitation prior to extraction is the most efficient method in terms of yield and cost, using urine as a non-invasive source of DNA and providing an alternative diagnostic method at a low cost.
Resumo:
The concentration of orthophosphate ions released from Fe-K-P compounds (Fe3KH8(PO4)6 .6H2O and Fe3KH14(PO4)8 .4H2O) present in superphosphates increases with pH, which initially suggests that the agronomic effectiveness of P fertilizers containing high amounts of these compounds would also increase with soil pH but studies considering activity, instead of concentration, are necessary. With this purpose, both compounds were synthesized under laboratory conditions, characterized by elemental chemical analysis, optical microscopy, X ray diffractometry, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS), and used in a solubility study. Solutions of 0.01, 0.05 and 0.1 mol L-1 NaCl with pH adjusted to 3.0, 4.0, 5.0, 5.5, 6.0, 6.5, 7.0 and 7.5 were prepared for the solubility study of H8-syn, H14-syn and a phosphate rock (PR) from Brazil. The orthophosphate activity as H2PO4- and HPO4(2-) was calculated in each situation as related to pH and ionic strength using software MINTEQ. The remaining precipitates after equilibrium were chemically analyzed and subjected to X ray, SEM and EDS. Results of chemical analysis and instrumental techniques confirmed the preparation method. The activity of orthophosphate ions of both compounds tended to decrease under increasing pH and/or ionic strength of the solution, which in turn suggests that an increase in the solution pH does not necessarily promote an increase in the P bioavailability for plant uptake. This can be important when evaluating agronomic data of P fertilizers with high contents of these two Fe-K-P compounds.
Resumo:
A 16S rRNA gene PCR-based assay was developed aiming at a fast molecular diagnostic method to differentiate the two phylogenetically closely related species Bradyrhizobium japonicum and B. elkanii, isolated from soybean nodules, in order to identify those more competitive and comprising greater nitrogen fixation ability for use in the formulation of commercial inoculants. The assay used was able to discriminate ten reference strains belonging to these two Bradyrhizobium species, as well as to efficiently identify 37 strains isolated from fields cultivated with soybean.
Resumo:
This review presents the latest advances of the mechanisation in sample preparation using microwave oven. The fundamental principles of microwaves field interaction with matter are presented, followed by the basic principles of microwave equipment construction. Hyphenation of microwave oven with flow injection analysis or robotic are discussed as well as some metodological difficulties and solutions by its implementation.
Resumo:
Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.
Resumo:
The solution fluorescence of N-alkyl-2,3-naphthalimides (1-4) in polar protic and aprotic solvents was compared to the emission from solid samples resulting from the imide complexation with b-cyclodextrin or adsorption on the surface of microcrystalline cellulose. Solid samples of the inclusion complex 2,3-naphthalimides/b-cyclodextrin show maximum for fluorescence emission significantly different to the observed in methanolic solution. Beside this, a clear effect on the alkyl chain length could be observed for these samples which is probably due to differences in probe location inside the cyclodextrin cavity. The constancy for fluorescence quantum yield and fluorescence lifetime for the imides 1 - 4 adsorbed on microcrystalline cellulose suggests that, independently of the polarity of the solvent used for sample preparation, the probe is preferentially located on the cellulose surface. An increase of fluorescence quantum yield and fluorescence lifetime for solid samples, when compared to the values obtained in solution for the different solvents employed in this study (acetonitrile, methanol and water), is fully in accordance with a decrease of the probe mobility due to inclusion in b-cyclodextrin or to adsorption on cellulose.
Análise de cabelo: uma revisão dos procedimentos para a determinação de elementos traço e aplicações
Resumo:
Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed.
Resumo:
This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.