45 resultados para district cooling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to determine physiological stress markers, neutrophil:lymphocyte ratio (N/L) and corticoid concentrations, in gestating sows under different cooling systems. A sprinkling cooling system (SS) and a system based on fan-assisted evaporative cellulose pad (PS) were used. SS showed higher N/L ratio (1.095) than PS (0.850). Corticoid concentrations showed high variability. Corticosteroids are more efficient short-term stress indicators while N/L ratio is a good medium and long-term stress indicator. According to N/L ratio, gestating sows under PS benefit from a higher level of welfare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the forced-air cooling process of fruits occurs, besides the convective heat transfer, the mass transfer by evaporation. The energy need in the evaporation is taken from fruit that has its temperature lowered. In this study it has been proposed the use of empirical correlations for calculating the convective heat transfer coefficient as a function of surface temperature of the strawberry during the cooling process. The aim of this variation of the convective coefficient is to compensate the effect of evaporation in the heat transfer process. Linear and exponential correlations are tested, both with two adjustable parameters. The simulations are performed using experimental conditions reported in the literature for the cooling of strawberries. The results confirm the suitability of the proposed methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pigs are more sensitive to high environmental temperatures explained by the inability of sweating and panting properly when compared to other species of farmed livestock. The evaporative cooling system might favor the thermal comfort of animals during exposure to extreme environmental heat and reduce the harmful effects of heat stress. The purpose of this study was to assess the sensible heat loss and thermoregulation parameters from lactating sows during summer submitted to two different acclimatization systems: natural and evaporative cooling. The experiment was carried out in a commercial farm with 72 lactating sows. The ambient variables (temperature, relative humidity and air velocity) and sows physiological parameters (rectal temperature, surface temperature and respiratory rate) were monitored and then the sensible heat loss at 21days lactation was calculated. The results of rectal temperature did not differ between treatments. However, the evaporative cooling led to a significant reduction in surface temperature and respiratory rate and a significant increase in the sow's sensible heat loss. It was concluded that the use of evaporative cooling system was essential to increase sensible heat loss; thus, it should reduce the negative effects of heat on the sows' thermoregulation during summer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cerradão vegetation shares many species with savanna and forest areas and is one of the most vulnerable phytophysiognomies in the Cerrado (Brazilian savanna) biome. The floristic composition of the Cerradão Biological Reserve was examined between September/2007 and November/2008. A total of 282 species distributed among 194 genera and 75 families were encountered, demonstrating proportions of 0.91 herbaceous species and 0.54 shrub species for each tree species. Fabaceae, Asteraceae, Rubiaceae, Poaceae, Myrtaceae, Malpighiaceae, and Melastomataceae were the most species-rich families. Fully 72.3% of the species of this dystrophic cerradão were shared by cerrado and forest vegetations, while 60.43% were shared by other cerradão sites, although the largest proportion of species (91%) were shared with cerrado sensu stricto. No species was found to be exclusive to this cerradão site, but approximately 95% of all species were native to the Cerrado biome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Group C rotaviruses are fastidious in their in vitro cell culture requirements. Recent serosurveys indicate that antibody to group C rotavirus is present in 3-45% of the human population in certain geographic locations, suggesting that rotavirus group C infection is more prevalent than previously believed and that the low rate of detection of these agents is probably due to the lack of sensitive diagnostic assays. From March to December 1994, 406 fecal specimens were collected from children under five years of age who were outpatients at the emergency services of nine public hospitals in Brasília, Federal District, Brazil. In addition to the samples from children, one public outpatient unit requested virological investigation of a stool sample from an HIV-seropositive adult male with diarrhea of sudden onset. All samples were analyzed by enzyme immunoassay for group A rotavirus and adenovirus (EIARA) and by polyacrylamide gel electrophoresis (PAGE). One hundred and seven (26%) were positive for group A rotavirus. Four samples from children and the sample from the HIV-seropositive patient, although negative by EIARA, showed a group C rotavirus profile by PAGE and were positive for rotavirus by electron microscopy. Using specific VP6 and VP7 primers for group C rotavirus, a reverse transcriptase-polymerase chain reaction (RT-PCR) was performed and products were detected by agarose gel electrophoresis and ethidium bromide staining. These products were confirmed to be specific for group C rotavirus by using digoxigenin-oligonucleotide probes, Southern hybridization and chemiluminescent detection. The five positive group C rotavirus samples were detected in August (3 samples) and September (2 samples). To the best of our knowledge, this is the first report of group C rotavirus detected in the Federal District, Brazil and in an HIV-seropositive patient with acute gastroenteritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Findings on the effects of weather on health, especially the effects of ambient temperature on overall morbidity, remain inconsistent. We conducted a time series study to examine the acute effects of meteorological factors (mainly air temperature) on daily hospital outpatient admissions for cardiovascular disease (CVD) in Zunyi City, China, from January 1, 2007 to November 30, 2009. We used the generalized additive model with penalized splines to analyze hospital outpatient admissions, climatic parameters, and covariate data. Results show that, in Zunyi, air temperature was associated with hospital outpatient admission for CVD. When air temperature was less than 10°C, hospital outpatient admissions for CVD increased 1.07-fold with each increase of 1°C, and when air temperature was more than 10°C, an increase in air temperature by 1°C was associated with a 0.99-fold decrease in hospital outpatient admissions for CVD over the previous year. Our analyses provided statistically significant evidence that in China meteorological factors have adverse effects on the health of the general population. Further research with consistent methodology is needed to clarify the magnitude of these effects and to show which populations and individuals are vulnerable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this research was to produce and characterize lipid particles (MpLs) that may be used as carriers of high amounts of hydrophilic core and evaluate the influence of the core amount on the performance of lipid microparticles. The MpLs were produced by spray cooling from solid and liquid lipid mixtures (stearic and oleic fatty acids and partly hydrogenated vegetable fat) containing glucose solution as core and soy lecithin as surfactant. The performance of MpLs was evaluated by means of the effective amount of encapsulated core, the core amount present on the surface of MpLs (superficial glucose) and the core release profile in aqueous solution. Morphological observations showed that MpLs presented spherical shape and a rugged and continuous surface, and an average diameter between 25 and 32 µm. The effective amount of encapsulated core was greater than 78% for all formulations evaluated. Larger amounts of superficial glucose were found in formulations in which more concentrated glucose solutions were used, regardless of the glucose lipid-solution ratio. The release results showed that core retention was significantly influenced by the glucose solution concentration, whereas release modulation was influenced by the glucose lipid-solution ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poultry carcasses have to be chilled to reduce the central breast temperatures from approximately 40 to 4 °C, which is crucial to ensure safe products. This work investigated the cooling of poultry carcasses by water immersion. Poultry carcasses were taken directly from an industrial processing plant and cooled in a pilot chiller, which was built to investigate the influence of the method and the water stirring intensity on the carcasses cooling. A simplified empiric mathematical model was used to represent the experimental results. These results indicated clearly that the understanding and quantification of heat transfer between the carcass and the cooling water is crucial to improve processes and equipment. The proposed mathematical model is a useful tool to represent the dynamics of carcasses cooling, and it can be used to compare different chiller operational conditions in industrial plants. Therefore, this study reports data and a simple mathematical tool to handle an industrial problem with little information available in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, water uptake by poultry carcasses during cooling by water immersion was modeled using artificial neural networks. Data from twenty-five independent variables and the final mass of the carcass were collected in an industrial plant to train and validate the model. Different network structures with one hidden layer were tested, and the Downhill Simplex method was used to optimize the synaptic weights. In order to accelerate the optimization calculus, Principal Component Analysis (PCA) was used to preprocess the input data. The obtained results were: i) PCA reduced the number of input variables from twenty-five to ten; ii) the neural network structure 4-6-1 was the one with the best result; iii) PCA gave the following order of importance: parameters of mass transfer, heat transfer, and initial characteristics of the carcass. The main contributions of this work were to provide an accurate model for predicting the final content of water in the carcasses and a better understanding of the variables involved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooked vegetables are commonly used in the preparation of ready-to-eat foods. The integration of cooking and cooling of carrots and vacuum cooling in a single vessel is described in this paper. The combination of different methods of cooking and vacuum cooling was investigated. Integrated processes of cooking and vacuum cooling in a same vessel enabled obtaining cooked and cooled carrots at the final temperature of 10 ºC, which is adequate for preparing ready-to-eat foods safely. When cooking and cooling steps were performed with the samples immersed in boiling water, the effective weight loss was approximately 3.6%. When the cooking step was performed with the samples in boiling water or steamed, and the vacuum cooling was applied after draining the boiling water, water loss ranged between 15 and 20%, which caused changes in the product texture. This problem can be solved with rehydration using a small amount of sterile cold water. The instrumental textural properties of carrots samples rehydrated at both vacuum and atmospheric conditions were very similar. Therefore, the integrated process of cooking and vacuum cooling of carrots in a single vessel is a feasible alternative for processing such kind of foods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical model previously developed to study microbial growth in food products under an isothermal environment was adapted to a time-varying temperature regime. The resulting model was applied to study the growth of Clostridium perfringens in meat products. This micro-organism is of particular relevance to public health and economy due to the loss of productivity caused by it. Results showed a similar performance of the model used compared to the Baranyi model under an isothermal situation and a slightly better performance under a non-isothermal temperature profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The search for efficient and accessible cooling systems has increased worldwide. This study aims to build and evaluate an evaporative cooling system using a water driven ejector, allowing it to be installed in places with plenty of water. The system was investigated varying the flow rate and temperature of the circulating water, temperature of the replacement water, and coefficient of performance. The best vacuum obtained was 8.5 kPa at nominal operating conditions of 4.1 ± 0.1 m³/h and 5 ± 0.5 ºC for the circulating water reaching the temperature of 9.7 ± 0.5 ºC. The pulse-like disturbance generated by replacing the cooling water at different periods of times did not result in significant affect vacuum destabilization and the temperature rise in the cooling tank. The coefficient of performance of the system at the highest thermal power of 92.27 W was 0.077, which was underestimated due to possible problems related to pump efficiency. The system evaluated under the conditions proposed can be very efficient for cooling fluids at higher temperatures, and it can be complementary to main refrigeration systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biofilms in milk cooling tanks compromise product quality even on farms. Due to the lack of studies of this topic, this study evaluated the microbiological conditions of raw milk cooling tanks on farms and characterized the microorganisms isolated from these tanks. Samples were wiped off with sterile swabs from seven milk cooling tanks in three different points in each tank. Mesophiles and psychrotrophic counts were performed in all samples. The isolation of Pseudomonas spp., Bacillus cereus and atypical colonies formed on selective media were also performed, totalizing 297 isolates. All isolates were tested for protease and lipase production and biofilm formation. Of the total isolates, 62.9% produced protease, 55.9% produced lipase, and 50.2% produced biofilm. The most widespread genus inside the milk cooling tank was Pseudomonas since it was not possible to associate this contamination with a single sampling point in the equipment. High counts of microorganisms were found in some cooling tanks, indicating poor cleaning of the equipment and providing strong evidences of microbial biofilm presence. Moreover, it is worth mentioning the milk potential contamination with both microbial cells and their degrading enzymes, which compromises milk quality.