247 resultados para antigen specificity
Resumo:
Crossed immunoelectrophoresis (IEC) was used for detection of free and complexed circulating polisaccharide anodic antigen (AgCA) of Schistosoma mansoni in sera of infected hamsters. An attempt was also done to detect AgCA in human sera from patients infected with S. mansoni. The conditions for isolation and detection of complexed AgCA were established. The sensitivity of IEC was increased by incorporation of 2% polyethylene glicol (PEG) to the agarose and by maintaining the system at 4°C during the electrophoretic run. Free AgCA was detected in 12 and the complexed in 30 of the 37 hamsters sera analysed. Correlation between AgCA (free and complexed) and the parasite load was observed. AgCA was not detected, under the experimental conditions used, in human sera from 7 patients in the acute and 23 in the chronic phase of infection.
Resumo:
A serological study was carried out to evaluate the causal relationship of acute diarrhoea and rotavirus in children under five years of age. The rotaviral infection was demonstrated in paired sera by determining the antibody titers by immunofluorescence test (IF). Bovine rotavirus-infected MA-104 cell culture was used as substratum for IF. Out of 80 paired sera it was shown that 23 (28.75%) presented seroconversion, 19 (23.75%) samples showed a twofold increase in their titers and 38 (47.5%) had no increase in rotavirus antibody. This result is discussed on the light of previously obtained results on viral antigen detection by counterimmunoelectrosmophoresis (CIEOP).
Resumo:
Sixteen S. mansoni infected and untreated patients (5 with recent infection and 11 with chronic disease) were evaluated for their in vitro natural killer (NK) activity against the NK sensitive target K562 cell line. NK levels in 9 out of 11 patients (82%) with chronic disease were significantly lower (mean = 15 ± 6%),compared with patients recently infected (mean = 41 ± 9% p < 0.001) and with the control group (mean = 38 ± 13% p < 0.001). However, both patients and controls NK activity was stimulated by soluble adult worm antigens (SAWA), indicating that NK function even in the chronic stage of the infection is able to respond to the parasite antigens. These results suggest the possibility of NK cell participation as effector mechanism against S. mansoni.
Resumo:
The antigenicity of promastigotes of Leishmania braziliensis braziliensis (L. b.braziliensis) treated with 1% sodium desoxycholate in 10 mM Tris-Hcl pH 8.2 was analysed by immunoblot using as probes sera from American cutaneous leishmaniasis (ACL), American visceral leishmaniasis (AVL), schistosomiasis, malaria and Chagas' disease. The ACL sera reacted constantly with a 60 kD band. No reactivity to this protein was observed with sera from the other diseases above mentioned indicating that the 60 kD protein may be used in serodiagnosis for ACL.
Resumo:
Sera from 299 fishermen 16 to 80 years old, residents in Cananeia and Iguape counties, southern cost of São Paulo State, Brazil, were studied in order to identify a possible association between the prevalence of specific antibodies to the hepatitis B virus (HBV) and exposure to haematophagus mosquitoes evaluated by the prevalence of arbovirus antibodies. This professional group presented the highest prevalence of arbovirus antibodies (54.1%) in past investigations carried out in this heavily forested region. Detection of antibody to hepatitis B core antigen (anti-HBc) in the sera was done by enzyme immunoassay (Roche). Prevalence of anti-HBc antibodies in this group was 31.4% (94/299) which is very high compared with 7.2% to 15.0% for different groups of healthy adults in State of São Paulo. No significant difference is observed between the prevalences of HBV antibodies in Iguape and Cananeia. Prevalence of anti-HBc and anti-arbovirus antibodies increases with age. There is a concordance in the distribution according to age groups of the frequency of anti-HBc and anti-arbovirus positive sera. Ag HBs was detected in 4% of the studied sera. These results support the hypothesis that the transmission of the hepatitis B virus and the arboviruses may be due to the same factor, one of the possibilities would be by anthropophilic mosquitoes.
Resumo:
A dot enzyme-linked immunosorbent assay (DOT-ELISA) was developed to detect specific antibodies in cerebrospinal fluid (CSF) for human neurocysticercosis immunodiagnosis, with Cysticercus cellulosae antigen dotted on a new solid-phase. This was represented by sheets of a synthetic polyester fabric impregnated with a polymerized resin (N-methylol-acrylamide). A very stable preparation was thus obtained, the antigen being covalently bound by cross-linking with free N-methylol groups on the resin. Since robust, no special care was necessary for handling the solid-phase. The test could be performed at room-temperature. From 30 CSF samples assayed, 14 were positive, from a group of 15 cases of neurocysticercosis, with titers from 1 to 128; 15 other samples, from normals or other neurological diseases, were all negative. Test characteristics seem to indicate it as adequate for epidemiological surveys. A more detailed study on sensitivity, specificity, reproducibility and the use in serum samples is being conducted.
Resumo:
This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.
Resumo:
The performance of an antigen of L. major-like promastigotes for the serological diagnosis of mucocutaneous leishmaniasis in the IgG-immunofluorescent test was compared to that of an antigen of L. braziliensis braziliensis. Each antigen was used to test two hundred and twenty-four sera of etiologies such as mucocutaneous leishmaniasis, deep mycoses, toxoplasmosis, malaria, Chagas' disease, visceral leishmaniasis, anti-nuclear factor, schistosomaiasis, rheumatoid factor and normal controls. Agreement between responses to each antigen was high: 77.2% of leishmaniases sera agreed on a positive or a negative result to both antigens and 91.1 % of control sera. Cross reactivity was restricted to Chagas' disease sera, visceral leishmaniasis, anti-nuclear factor and paracoccidiodomycosis. The quantitative response of leishmaniasis and Chagas' disease sera to both antigens was evaluated by a linear regression; although the y-intercept and the slope were different for each antigen, neither was better than the other in the disclosure of anti-Leishmania antibodies. In the case of Chagas' disease sera the L. major-like antigen was better than L. b. braziliensis' to disclose cross-reacting antibodies.
Resumo:
Yeast forms of five strains of Paracoccidioides brasiliensis (SN, 2, 18, 192 and JT- 1) were cultured in a synthetic medium for obtaining methylic antigens. These antigens were lyophilized and studied for each strain, to determine their partial biochemical composition, through measurements of total lipid, protein and carbohydrate contents. Lipids of methylic antigens were purified and analysed for sterols, phospholipids, glycolipids, li-poproteins, and partial characterization of sterols. Significant differences were found among antigenic preparations derived from distinct P. brasiliensis strains, in relation to the quantitative determinations. On the other hand, sterol analysis revealed the presence of ergosterol, lanosterol and squalene in all samples. The diversity verified in the biochemical characteristics of antigens derived from different P. brasiliensis strains, confirm the need of using a pool of fungal samples in order to produce antigen preparations for serological procedures without hampering their sensitivity.
Resumo:
The specificity and sensitivity of the enzyme immunoassay (EIA), presently used in South America areas where hydatidosis caused by Echinococcus granulosus is endemic, was compared to two alternative EIA. One of these uses an hydatid antigen of different prepraration and the other vesicular fluid of Taenia crassiceps cisticerci (VFCC). The effect of previous neutralization in the serum sample of antibodies anti-normal ovine or murine sera and anti-phosphorylcholine on the diagnostic efficiency of these EIA was studied. The frequency of distribution of the titers obtained with normal sera, hydatid sera positive to DD5 test and hydatid sera negative to DD5 test in three EIA systems was analyzed. Results showed a significant decrease of sensitivity of the EIA using VFCC when compared to these EIA using hydatid antigens. This makes inconvenient the use of VFCC for the immunodiagnosis of hydatid disease. No significant differences between the two EIA using hydatid antigens were observed. SDS-PAGE analysis showed remarkable differences between the VFCC and the hydatid antigens composition and some differences among these latters probably due to manufacturing procedures.
Resumo:
Two groups of patients undergoing hemodialysis (HD) maintenance were evaluated for their antibody response to non-structural c100/3 protein and structural core protein of hepatitis C virus (HCV). Forty-six patients (Group 1) never presented liver abnormalities during HD treatment, while 52 patients (Group 2) had either current or prior liver enzyme elevations. Prevalence rates of 32.6% and 41.3% were found for anti-c100/3 and anti-HCV core antibodies, respectively, in patients with silent infections (Group 1). The rate of anti-c100/3 in patients of Group 2 was 71.15% and reached 86.5% for anti-HCV core antibodies. The recognition of anti-c100/3 and anti-core antibodies was significantly higher in Group 2 than in Group 1. A line immunoassay composed of structural and non-structural peptides was used as a confirmation assay. HBV infection, measured by the presence of anti-HBc antibodies, was observed in 39.8% of the patients. Six were HBsAg chronic carriers and 13 had naturally acquired anti-HBs antibodies. The duration of HD treatment was correlated with anti-HCV positivity. A high prevalence of 96.7% (Group 2) was found in patients who underwent more than 5 years of treatment. Our results suggest that anti-HCV core ELISA is more accurate for detecting HCV infection than anti-c100/3. Although the risk associated with the duration of HD treatment and blood transfusion was high, additional factors such as a significant non-transfusional spread of HCV seems to play a role as well. The identification of infective patients by more sensitive methods for HCV genome detection should help to control the transmission of HCV in the unit under study.
Resumo:
The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.
Resumo:
The alkaline soluble Trypanosoma cruzi epimastigote antigen (ASEA) was assessed in dot-ELISA for the diagnosis of Chagas' disease. Serum samples (355) from chagasic and non-chagasic patients were studied, and IgG antibodies to ASEA were found in all patients with chronic Chagas' disease. In non-chagasic patients 95.6% were negative, except for those with leishmaniasis (visceral and mucocutaneous), and some patients from control group reacted in low titers. The data indicate that dot-ELISA using ASEA is suitable for seroepidemiologic surveys to be employed in endemic areas for Chagas' disease.