133 resultados para Valve mitrale


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases are the main causes of mortality and morbidity in Brazil. Their primary and secondary preventions are a priority for the health system and require multiple approaches for increased effectiveness. Biomarkers are tools used to identify with greater accuracy high-risk individuals, establish a faster diagnosis, guide treatment, and determine prognosis. This review aims to highlight the importance of biomarkers in clinical cardiology practice and raise relevant points regarding their application and perspectives for the next few years. This document was divided into two parts. This second part addresses the application of biomarkers in coronary heart disease, valvular diseases, cardio-oncology, pulmonary embolism, and cardiorenal syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Isolated cleft mitral valve (ICMV) may occur alone or in association with other congenital heart lesions. The aim of this study was to describe the profile of cardiac lesions associated with ICMV and their potential impact on therapeutic management. Methods: We conducted a descriptive study with data retrieved from the Congenital Heart Disease (CHD) single-center registry of our institution, including patients with ICMV registered between December 2008 and November 2014. Results: Among 2177 patients retrieved from the CHD registry, 22 (1%) had ICMV. Median age at diagnosis was 5 years (6 days to 36 years). Nine patients (40.9%) had Down syndrome. Seventeen patients (77.3%) had associated lesions, including 11 (64.7%) with accessory chordae in the left ventricular outflow tract (LVOT) with no obstruction, 15 (88.2%) had ventricular septal defect (VSD), three had secundum atrial septal defect, and four had patent ductus arteriosus. Thirteen patients (59.1%) required surgical repair. The decision to proceed with surgery was mainly based on the severity of the associated lesion in eight patients (61.5%) and on the severity of the mitral regurgitation in four patients (30.8%). In one patient, surgery was decided based on the severity of both the associated lesion and mitral regurgitation. Conclusion: Our study shows that ICMV is rare and strongly associated with Down syndrome. The most common associated cardiac abnormalities were VSD and accessory chordae in the LVOT. We conclude that cardiac lesions associated with ICMV are of major interest, since in this study patients with cardiac lesions were diagnosed earlier. The decision to operate on these patients must take into account the severity of both mitral regurgitation and associated cardiac lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.