86 resultados para Validation séquentielle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To validate an instrument to assess quality of mobile emergency pre-hospital care. METHOD A methodological study where 20 professionals gave their opinions on the items of the proposed instrument. The analysis was performed using Kappa test (K) and Content Validity Index (CVI), considering K> 0.80 and CVI ≥ 0.80. RESULTS Three items were excluded from the instrument: Professional Compensation; Job Satisfaction and Services Performed. Items that obtained adequate K and CVI indexes and remained in the instrument were: ambulance conservation status; physical structure; comfort in the ambulance; availability of material resources; user/staff safety; continuous learning; safety demonstrated by the team; access; welcoming; humanization; response time; costumer privacy; guidelines on care; relationship between professionals and costumers; opportunity for costumers to make complaints and multiprofessional conjunction/actuation. CONCLUSION The instrument to assess quality of care has been validated and may contribute to the evaluation of pre-hospital care in mobile emergency services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE To describe the stages of construction and validation of an instrument in order to analyze the adherence to best care practices during labour and birth. METHOD Methodological research, carried out in three steps: construction of dimensions and items, face and content validity and semantic analysis of the items. RESULTS The face and content validity was carried out by 10 judges working in healthcare, teaching and research. Items with Content Validity Index (CVI) ≥ 0.9 were kept in full or undergone revisions as suggested by the judges. Semantic analysis, performed twice, indicated that there was no difficulty in understanding the items. CONCLUSION The instrument with three dimensions (organization of healthcare network to pregnancy and childbirth, evidence-based practices and work processes) followed the steps recommended in the literature, concluded with 50 items and total CVI of 0.98.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract OBJECTIVE Developing and validating an instrument to evaluate the playfulness of games in health education contexts. METHODOLOGY A methodological, exploratory and descriptive research, developed in two stages: 1. Application of an open questionnaire to 50 graduate students, with content analysis of the answers and calculation of Kappa coefficient for defining items; 2. Procedures for construction of scales, with content validation by judges and analysis of the consensus estimate byContent Validity Index(CVI). RESULTS 53 items regarding the restless character of the games in the dimensions of playfulness, the formative components of learning and the profiles of the players. CONCLUSION Ludicity can be assessed by validated items related to the degree of involvement, immersion and reinvention of the subjects in the game along with the dynamics and playability of the game.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantitative model of water movement within the immediate vicinity of an individual root is developed and results of an experiment to validate the model are presented. The model is based on the assumption that the amount of water transpired by a plant in a certain period is replaced by an equal volume entering its root system during the same time. The model is based on the Darcy-Buckingham equation to calculate the soil water matric potential at any distance from a plant root as a function of parameters related to crop, soil and atmospheric conditions. The model output is compared against measurements of soil water depletion by rice roots monitored using γ-beam attenuation in a greenhouse of the Escola Superior de Agricultura "Luiz de Queiroz"/Universidade de São Paulo(ESALQ/USP) in Piracicaba, State of São Paulo, Brazil, in 1993. The experimental results are in agreement with the output from the model. Model simulations show that a single plant root is able to withdraw water from more than 0.1 m away within a few days. We therefore can assume that root distribution is a less important factor for soil water extraction efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to evaluate the relationship between the diagnosis and recommendation integrated system (DRIS) indices and foliar nutrient concentrations, to establish optimum foliar nutrient concentrations with DRIS and to validate the DRIS norms for sugarcane crop. Foliar nutrient concentrations from 126 sugarcane commercial fields were analyzed during the 1996/97 season, to calculate DRIS indices. Regression analysis was used to fit a model relating DRIS indices to nutrient concentrations. Experiments were carried out during the 1997/98 season, whose treatments consisted of the addition of the most limiting nutrients according to DRIS. A new diagnosis was performed. At the end of 1997/98 season, the yields of each plot were collected. Analysis of variance and Duncan test (5%) were used for the evaluation of the collected data. There was a positive and significant relationship between sugarcane foliar nutrient concentrations and DRIS indices. The optimum foliar nutrient concentrations for sugarcane are: 13.4 g ha-1 for N, 1.91 g ha-1 for P, 12.2 g ha-1 for K, 2.99 g ha-1 for Ca, 2.15 g ha-1 for Mg, 1.61 g ha-1 for S, 4.48 mg ha-1 for Cu, 67.8 mg ha-1 for Mnand 11.7 mg ha-1 for Zn. DRIS norms evaluated are useful to correct nutritional imbalances and to increase sugarcane yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to validate microsatellite markers associated with resistance to soybean cyst nematode (Heterodera glycines Ichinohe) races 3 and 14, in soybean (Glycine max L.) genotypes, for use in marker-assisted selection (MAS) programs. Microsatellites of soybean linkage groups A2, D2 and G were tested in two populations, and their selection efficiencies were determined. The populations were 65 F2:3 families from Msoy8001 (resistant) x Conquista (susceptible) cross, and 66 F2:3 families of S5995 (resistant) x Renascença (susceptible) cross, evaluated for resistance to races 3 and 14, respectively. Families with female index up to 30% were considered moderately resistant. Markers of A2 and G linkage groups were associated with resistance to race 3. Markers Satt309 and GMENOD2B explained the greatest proportion of phenotypic variance in the different groups. The combinations Satt309+GMENOD2B and Satt309+Satt187 presented 100% selection efficiency. Resistance to race 14 was associated with markers of G linkage group, and selection efficiency in the Satt309+Satt356 combination was 100%. The selection differential obtained by phenotypic and marker assisted selection showed that both can result in similar gains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method is described for the determination of the herbicide bispyribac-sodium in surface water, especially from river and irrigated rice water samples. The method involves extraction in solid phase and quantification by high performance liquid chromatography with diode array detection (HPLC-DAD). After optimization of the extraction and separation parameters, the method was validated. The method presented average recoveries of 101.3 and 97.7%, under repeatability and intermediate precision conditions, respectively, with adequate precision (RSD from 0.9 to 7.5%). The method was applied for the determination of bispyribac-sodium in surface water samples with a limit of detection of 0.1 μg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.