104 resultados para Validation of analytical methods
Resumo:
Polygala cyparissias is a plant widespread in Southern Latin America. Recently, we demonstrated the gastroprotective activity of the extract, as well as for one of the isolated metabolites-1,7-dihydroxy-2,3-methylenedioxyxanthone (MDX). In this study, a HPLC method for the quantification of MDX was validated. The HPLC method was linear (0.5-24 µg mL-1 of MDX) with good accuracy, precision and robustness. The content of MDX in the extracts from whole and different parts of the plant ranged from 0 to 5.4 mg g-1 and the gastroprotective index ranged from 72.1 to 99.1%. Thus, the method might be used for the standardization of the extracts based on the MDX marker.
Resumo:
Xanthyletin is used as an inhibitor of the symbiotic fungus (Leucoagaricus gongylophorus) of the leaf-cutting ant (Atta sexdens rubropilosa), one of the most significant agricultural plague insects. The incorporation of this compound into nanoparticles is a promising approach to effectively control leaf-cutting ants. This study presents the development and validation of a specific analytical method using high-performance liquid chromatography (HPLC) for quantification of the xanthyletin content in biodegradable polymeric nanoparticles. The analytical methodology developed was specific, linear, accurate, precise, and robust. The absolute recovery of xanthyletin in colloidal suspensions was nearly 100%. The HPLC method proved reliable for the quantification of xanthyletin content in nanoparticle formulations.
Resumo:
Scarcity of long-term series of sediment-related variables has led watershed managers to apply mathematical models to simulate sediment fluxes. Due to the high efforts for installation and maintenance of sedimentological gauges, tracers have been pointed out as an alternative to validate soil redistribution modelling. In this study, the 137Cs technique was used to assess the WASA-SED model performance at the Benguê watershed (933 km²), in the Brazilian semiarid. Qualitatively, good agreement was found among the 137Cs technique and the WASA-SED model results. Nonetheless, quantitatively great differences, up to two orders of magnitude, were found between the two methods. Among the uncertainties inherent to the 137Cs technique, definition of the reference inventory seems to be a major source of imprecision. In addition, estimations of water and sediment fluxes with mathematical models usually also present high uncertainty, contributing to the quantitative differences of the soil redistribution estimates with the two methods.
Resumo:
Objective: To develop and validate an instrument for measuring the acquisition of technical skills in conducting operations of increasing difficulty for use in General Surgery Residency (GSR) programs. Methods: we built a surgical skills assessment tool containing 11 operations in increasing levels of difficulty. For instrument validation we used the face validaity method. Through an electronic survey tool (Survey MonKey(r)) we sent a questionnaire to Full and Emeritus members of the Brazilian College of Surgeons - CBC - all bearers of the CBC Specialist Title. Results: Of the 307 questionnaires sent we received 100 responses. For the analysis of the data collected we used the Cronbach's alpha test. We observed that, in general, the overall alpha presented with values near or greater than 0.70, meaning good consistency to assess their points of interest. Conclusion: The evaluation instrument built was validated and can be used as a method of assessment of technical skill acquisition in the General Surgery Residency programs in Brazil.
Resumo:
Analysis of faecal glucocorticoid metabolites provides a powerful noninvasive tool for monitoring adrenocortical activity in wild animals. However, differences regarding the metabolism and excretion of these substances make a validation for each species and sex investigated obligatory. Although maned wolves (Chrysocyon brachyurus) are the biggest canids in South America, their behaviour and physiology are poorly known and they are at risk in the wild. Two methods for measuring glucocorticoid metabolites in maned wolves were validated: a radio- and an enzyme immunoassay. An ACTH challenge was used to demonstrate that changes in adrenal function are reflected in faecal glucocorticoid metabolites. Our results suggest that both methods enable a reliable assessment of stress hormones in maned wolves avoiding short-term rises in glucocorticoid concentrations due to handling and restraint. These methods can be used as a valuable tool in studies of stress and conservation in this wild species.
Resumo:
A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.
Resumo:
The evaluation of filtration methods on the yield and oleochemicals characteristics on the crude fish oil from the soapstock of marine fish for purposes of nutrition has been conducted in this work. The analytical properties of the crude and the neutralized oil with three excesses of sodium hydroxide (NaOH, 20%, 40% and 60%) were carried out on two different ways with organza and the “glass wool”. The neutralization of the oil brought about a notable improvement in the analytical properties of the oil. Thus, it leads to a high quality fish oil in terms of taste, colour, odours, shelf life and market value. Based on the improved characteristics of the oil, it could be suitable for applications in pharmaceutical and food industries.
Resumo:
ABSTRACTAiming to compare three different methods for the determination of organic carbon (OC) in the soil and fractions of humic substances, seventeen Brazilian soil samples of different classes and textures were evaluated. Amounts of OC in the soil samples and the humic fractions were measured by the dichromate-oxidation method, with and without external heating in a digestion block at 130 °C for 30 min; by the loss-on-ignition method at 450 °C during 5 h and at 600 °C during 6 h; and by the dry combustion method. Dry combustion was used as reference in order to measure the efficiency of the other methods. Soil OC measured by the dichromate-oxidation method with external heating had the highest efficiency and the best results comparing to the reference method. When external heating was not used, the mean recovery efficiency dropped to 71%. The amount of OC was overestimated by the loss-on-ignition methods. Regression equations obtained between total OC contents of the reference method and those of the other methods showed relatively good adjustment, but all intercepts were different from zero (p < 0.01), which suggests that more accuracy can be obtained using not one single correction factor, but considering also the intercept. The Walkley-Black method underestimated the OC contents of the humic fractions, which was associated with the partial oxidation of the humin fraction. Better results were obtained when external heating was used. For the organic matter fractions, the OC in the humic and fulvic acid fractions can be determined without external heating if the reference method is not available, but the humin fraction requires the external heating.
Resumo:
In Brazil, more than 500,000 new cases of malaria were notified in 1992. Plasmodium falciparum and P.vivax are the responsible species for 99.3% of the cases. For adequate treatment, precoce diagnosis is necessary. In this work, we present the results of the traditional Plasmodia detection method, thick blood film (TBF), and the results of alternative methods: Immunofluorescence assay (IFA) with polyclonal antibody and Quantitative Buffy Coat method (QBC)® in a well defined population groups. The analysis were done in relation to the presence or absence of malaria clinical symptoms. Also different classes of immunoglobulins anti-P.falciparum were quantified for the global analysis of the results, mainly in the discrepant results. We concluded that alternative methods are more sensitive than TBF and that the association of epidemiological, clinical and laboratory findings is necessary to define the presence of malaria.
Resumo:
The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.
Resumo:
Two passive methods in the assessment of intradomiciliary infestation by Rhodnius ecuadoriensis were tested: (i) the Gomes Nuñez sensor box (GN), (ii) sheets of white typing paper and (iii) one active timed manual method. The study was carried out in the Alto Chicama River Valley, Province of Gran Chimú, Department of La Libertad. The study design consisted of an initial searching of triatomines inside of the domestic environment by the manual capture active procedure (man/hour) covering all the studied houses. Then, matched pairs of GN boxes and paper sheets were simultaneously installed in the bedrooms of 207 households distributed in 19 localities. A comparative prospective trial of these passive detection devices were monitored at 2, 4 and, finally 6 months follow-up. Parasitological Trypanosoma rangeli and/or T. cruzi infections were investigated in two houses with high level of infestation by R. ecuadoriensis. 16.9% of the 207 households investigated by an initial active manual method were infested with R. ecuadoriensis. The proportion of infested houses fluctuated from 6.2 to 55.5% amongst the 19 localities investigated. T. rangeli natural infection was detected in R. ecuadoriensis specimens collected in two households. Parasite rates in the bugs ranged from 16.6 to 21.7% respectively. The most striking fact was an average rate of salivary gland infection ranging from 7.4 to 8.3%. At the end of the sixth month period, a cumulative incidence of 31.4% of positive GN boxes against 15.9% for paper sheets was recorded. All three methods combined detected domestic infestation in 129 (62.3%) of the 207 houses studied in the 19 localities. The range of houses infested varies from 6.7% to 92.9%. In areas with low bug density infestation rates, the methodology experienced in our studies, seems to be the best choice for investigations on domestic R. ecuadoriensis populations.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.