58 resultados para Ultraviolet supercontinuum
Resumo:
A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.
Resumo:
A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.
Resumo:
The post-preparative size-selective precipitation technique was applied in CdTe and CdSe semiconductor nanocrystals prepared via colloidal route in water. The synthesis of CdTe and CdSe nanoparticles and the effect of the post-preparative size-selective precipitation have been characterized mainly by mean of ultraviolet and visible absorption spectroscopy (UV-Vis). It was demonstrated that the size-selective precipitation are able to isolate particles of different sizes and purify the nanoparticles as well.
Resumo:
SiO2-TiO2 materials prepared by sol-gel method were evaluated in the photocatalytic degradation of diuron. The materials were prepared with and without surfactant cetyltrimethylammonium chloride at different temperatures (25, 50 and 100 ºC). The samples were characterized by N2 adsorption-desorption measurements, scanning electron microscopy, X-ray diffraction, ultraviolet-visible diffuse reflectance spectroscopy and infrared diffuse reflectance spectroscopy. The results showed that the materials synthesized with the surfactant had higher surface areas and band-gap values similar to anatase. All materials were more active than the commercial catalyst P-25 and better performance was achieved using the surfactant in the material synthesis.
Resumo:
Positive photoresists are widely used in lithographic process in microelectronics and in optics for the fabrication of relief components. With the aim of identifying molecular modifications among positive photoresists unexposed and previously exposed to ultraviolet light the electron stimulated ion desorption technique coupled to time-of-flight mass spectrometry was employed in the study of the AZ-1518 photoresist. Mass spectra were obtained as a function of the electron beam energy, showing specific changes related to the photochemical decomposition of the photoresist. This reinforces the applicability of the technique to investigate and characterize structural changes in photosensitive materials.
Resumo:
A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.
Resumo:
The interest in the use of evaporative light scattering detector (ELSD) for the analysis of different classes of natural products has grown over the years. This is because this detector has become an excellent alternative compared to other types of detectors, such as the refractive index detector and the ultraviolet (UV) detector. This review describes the basic principles of ELSD functioning and discusses the advantages and disadvantages in using an ELSD for the analysis of organic compounds. Additionaly, an overview, covering the last 23 years, of ELSD applications in natural products analysis (saponins, terpenes, carbohydrates, glycosides, alkaloids, steroids, flavonoids, peptides, polyketides, coumarins and iridoids) is presented and discussed.
Resumo:
Commonly used HPLC acetonitrile solvent has been through a worldwide shortage with a cost increase in 2008 and 2009. In order to get around this situation, a method by RP-HPLC employing methanol and aqueous acid mobile phase was developed and validated to evaluate simvastatin. The quality control assay and dissolution studies of this lipid-lowering drug were performed in diluents methanol and 0.01 M phosphate buffer with 0.5% SDS, pH 7, respectively. Dissolution test aliquots did not go through sample treatment, as described in USP SIM tablets monograph by ultraviolet spectrophotometry. The proposed method is fast, simple, feasible and robust.
Resumo:
Quaternary ammonium salts are the corrosion inhibitors most frequently used by the oil industry. In this study, the ultraviolet fluorescence technique was evaluated for the analysis of a quaternary ammonium salt in water as a corrosion inhibitor. The comparison with standard salt showed that an alkyl aryl quaternary ammonium salt is the main fluorophore, with emission maxima at 306 and 593 nm. The best instrumental parameters were: width of excitation and emission slits of 10 and 15 nm, respectively, and scan rate of 10 nm min-1. The presence of aromatic compounds and biocides affects the analysis of corrosion inhibitors.
Resumo:
The oxidation of sulphur compounds upon burning emits large quantities of SOx into the atmosphere. Therefore, there is growing interest in fast and accurate methods for analyzing sulphur content in fuels. The objective of this work was to compare four different methods of total sulphur determination in solid fuels. The methods used in this work were Eschka, Infrared, Thermal Conductivity Detection (TCD) and Ultraviolet Fluorescence Detection (UV). The preliminary results showed that TCD and UV methods (nonstandard methods for solid fuels) have similar precision to the infrared method (standard method) for high-sulphur coal samples.
Resumo:
A complex cation, diNOsarcobalt(III), [Co(diNOsar)]3+, (diNOsar = 1,8-dinitro-3,6,10,13,16,19-hexaazabicyclo-[6.6.6]eicosane), was synthesized and immobilized in the cavities of a Y zeolite by the reaction of precursor species in the pores of the zeolite. The encapsulated material was compared to the compound diNOsarcobalt(III) chloride, [Co(diNOsar)]Cl3. Both diNOsarcobalt(III) chloride and the zeolite-encapsulated complex, [Co(diNOsar)]3+/zeolite, were obtained in high yield and characterized by ultraviolet-visible and infrared spectroscopy. X-ray diffraction demonstrated the incorporation of the complex cation into the pores of the zeolite. The catalytic production of hydrogen peroxide from oxygenated water confirmed the successful synthesis of the complex diNOsarcobalt(III) immobilized in the zeolite.
Resumo:
Ultraviolet radiation corresponds to a fraction of electromagnetic radiation, covering wavelengths between 1 and 400 nm. Methods based on UV irradiation have become popular because it is possible to treat samples simply by applying energy, avoiding procedures that require the use of toxic substances, thus contributing to the development of Green Chemistry. This study aimed to assess the main applications of UV radiation reported in the literature and thoroughly described the construction of an alternative and low-cost photochemical reactor to be used for the pretreatment of samples in the laboratory. The use of this new photochemical reactor in the clean-up of milk samples for spectrofluorimetric measurements was also reported.
Resumo:
A simple procedure based on stir bar sorptive extraction and high-performance liquid chromatography-ultraviolet/photodiode array detection (SBSE/LC-UV/PAD) to determine intermediates and by-products of esfenvalerate is described. The influence of organic modifier, ionic strength, extraction time, temperature and pH were simultaneously evaluated by using a factorial experimental design. The utilization of different organic solvents and desorption times were also investigated to establish the optimal conditions for SBSE liquid desorption. Among the ten different peaks (intermediates and by-products) detected after degradation of esfenvalerate, eight (including 3-phenoxybenzoic acid and 3-phenoxybenzaldehyde) were successfully extracted by SBSE under the optimized conditions.
Resumo:
Cocaine is usually seized mixed with a wide variety of adulterants such as benzocaine, lidocaine, caffeine, and procaine. The forensic identification of cocaine in these street drug mixtures is normally performed using colorimetric testing kits, but these tests may suffer from interferences, producing false-positive results. Here, we describe the use of analytical techniques including attenuated total reflection Fourier transform infrared (ATR-FTIR) and ultraviolet-visible (UV-VIS) spectroscopies to distinguish between cocaine and other adulterants (lidocaine, promethazine, powdered milk and yeast) that yield positive results on the Scott test using the thiocyanate cobalt reagent. A further 13 substances were also analyzed using the Scott test.
Resumo:
This work aims to (1) produce and characterize the flour obtained from two varieties of canihua, cupi and illpa-inia, and (2) evaluate the ability of these flours to form biofilms. The flours produced contain proteins, starches, lipids, organic substances containing phenol groups, and high percentages of unsaturated fatty acids. Films produced from the illpa variety presented lower water vapor permeability and larger Young’s modulus values than the films formed from the cupi variety. Both films were yellowish and displayed a high light blocking ability (as compared with polyethylene films), which can be attributed to the presence of phenolic compounds. Furthermore, they showed lesser solubility and water permeability than other polysaccharide films, which may be the result of the higher protein (12%–13.8%) and lipid (11%) contents in canihua flours, as well as the formation of a larger number of S–S bonds. On the other hand, these films presented a single vitreous transition temperature at low temperatures (< 0 °C), crystallization of the A and Vh types, and an additional diffraction peak at 2 = 7.5º, ascribed to the presence of essential fatty acids in canihua flour. Canihua flour can form films with adequate properties and shows promise for potential applications in food packaging, because it acts as a good barrier to incident ultraviolet light.