58 resultados para Ultrasound (US)
Resumo:
We reviewed ultrasound features in patients with schistosomiasis mansoni. The alterations that we observed in acute and hepatosplenic schistosomiasis are described. The advantages and disadvantages of using ultrasound patterns in the evaluation of liver fibrosis are discussed. Other diseases that are important in the differential diagnosis of schistosomal liver fibrosis are presented. Ultrasound is an effective and flexible diagnostic tool in the evaluation of a variety of diseases. It presents no harmful effects to patients, allowing non-invasive studies in hospitalized patients and in other facilities.
Resumo:
No estudo aqui apresentado, aplicou-se um modelo de rede neural multicamadas para o apreçamento de calls sobre taxa de câmbio R$/US$, negociadas na Bolsa de Valores, Mercadorias & Futuros de São Paulo (BM&FBovespa), para o período de janeiro de 2004 a dezembro de 2007. A partir dos preços efetivamente praticados no mercado, comparou-se o desempenho entre essa técnica e o modelo de Black, utilizando-se métricas usuais de erro e testes estatísticos. Os resultados obtidos revelaram, em geral, a melhor adequação do modelo de inteligência artificial, em comparação ao modelo de Black, nos diferentes graus de moneyness.
Resumo:
OBJECTIVE: To determine the number of punctures in fine-needle aspiration biopsies required for a safe cytological analysis of thyroid nodules. MATERIALS AND METHODS: Cross-sectional study with focus on diagnosis. The study population included 94 patients. RESULTS: The mean age of the patients participating in the study was 52 years (standard-deviation = 13.7) and 90.4% of them were women. Considering each puncture as an independent event, the first puncture has showed conclusive results in 78.7% of cases, the second, in 81.6%, and the third, in 71.8% of cases. With a view to the increasing chance of a conclusive diagnosis at each new puncture, two punctures have showed conclusive results in 89.5% of cases, and three punctures, in 90.6% of cases with at least one conclusive result. CONCLUSION: Two punctures in fine-needle aspiration biopsies of thyroid nodules have lead to diagnosis in 89.5% of cases in the study sample, suggesting that there is no need for multiple punctures to safely obtain the diagnosis of thyroid nodules.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.
Resumo:
Objective: The present study was aimed at evaluating the contribution of transrectal prostate ultrasound in the screening for prostate neoplasias and in the guidance of prostate biopsies. Materials and Methods: Prospective study developed over a one-year period. All the patients with indication for prostate biopsy were evaluated. Regardless of PSA values, the patients underwent ultrasound in order to identify suspicious nodules (confirmed by two observers). Sextant biopsy was subsequently performed. In cases of finding suspicious nodules, an additional puncture directed to such nodules was done. Results: In a total of 155 cases the prevalence of malignancy was of 53%. Suspicious nodules were detected in 34 patients, and 25 where malignant (positive predictive value of 74%). The specificity and sensitivity for suspicious nodules were 88% and 31% respectively. Comparatively with the randomly obtained sextant specimens, the rate of findings of neoplasia was higher in the specimens obtained with puncture directed to the nodule (p = 0.032). No statistically significant difference was observed in the Gleason score for both types of specimens (p = 0.172). Conclusion: The high positive predictive value and the high rate of findings of neoplasia in specimens of suspicious nodules should be taken into consideration in the future. The authors suggest a biopsy technique similar to the one described in the present study (sextant biopsy plus puncture directed to the suspicious nodule).
Resumo:
AbstractThe authors review the main concepts regarding the importance of cleaning/disinfection of ultrasonography probes, aiming a better comprehension by practitioners and thus enabling strategies to establish a safe practice without compromising the quality of the examination and the operator productivity. In the context of biosafety, it is imperative to assume that contact with blood or body fluids represents a potential source of infection. Thus, in order to implement cleaning/disinfection practice, it is necessary to understand the principles of infection control, to consider the cost/benefit ratio of the measures to be implemented, and most importantly, to comprehend that such measures will not only benefit the health professional and the patient, but the society as a whole.
Resumo:
Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.
Resumo:
Intralaboratorial and interlaboratorial variabilities can be obtained by conducting an specially designed interlaboratory program. Using the analysis of variance technique one can calculate the r (repeatability) and R (reproducibility) indexes that can help participant laboratories to monitor their routine quality control procedures. An example is described using data obtained from an interlaboratory program where twelve laboratories determined total iron content in silicon metal sample by using flame atomic absorption spectrometry.
Resumo:
Objective:To evaluate the prevalence of carpal tunnel syndrome in candidates for bariatric surgery comparing with the non-obese population and verify the effects on it of bariatric treatment. Methods:We studiedthree groups of individuals: 1) patients waiting for bariatric surgery (preoperative); 2) individuals who had already undergone the procedure (postoperative); and 3) control group. We collected demographic and clinical data of carpal tunnel syndrome. The Ultrasound examination was carried out to diagnose the syndrome by measuring the median nerve area. Results:We included 329 individuals (114 in the preoperative group, 90 in the postoperative group and 125 controls). There was a higher prevalence of paresthesias (p=0.0003), clinical tests (p=0.0083) on the preoperative group when compared with controls (p<0.00001). There were lowe levels of paresthesias (p=0.0002) and median nerve area (p=0.04) in postoperative patients but with no significant difference in general. A significant difference was found between the preoperative and postoperative groups (p=0.05) in those who performed non-manual work.Conclusion: There was a higher prevalence of carpal tunnel syndrome in the preoperative group compared with the control one, but no significant difference was observed between the pre and postoperative groups in general. There was difference between pre and postoperative groups for non-manual workers.
Resumo:
OBJETIVO: analisar qual das características propostas pelo BIRADS-US tem maior impacto na diferenciação das lesões benignas das malignas. MÉTODOS: estudamos as características ultra-sonográficas do BIRADS em 384 nódulos submetidos à biópsia percutânea no período de fevereiro de 2003 a dezembro de 2006. Utilizou-se, para o exame, o aparelho Logic 5, com transdutor linear multifreqüencial de 7,5-12 MHz. A análise ultra-sonográfica do nódulo foi baseada no BIRADS-US levando em conta: forma, orientação, margem, limites da lesão, ecogenicidade, características acústicas posteriores, o tecido circunjacente e a presença de calcificações. Estes dados foram submetidos à análise estatística com modelo de regressão logística. Para o estudo de associação entre estas variáveis utilizamos o teste do c² e também calculamos a sensibilidade e a especificidade das variáveis "tecido ao redor", "calcificações", "efeito posterior", "limite da lesão" e "orientação". RESULTADOS: as lesões benignas representaram 42,4% e as malignas, 57,6%. A análise por regressão logística encontrou odds ratio (OR) aumentado para câncer de 7,7 vezes quando o tecido ao redor esteve alterado, de 6,2 vezes quando houve presença das microcalcificações no interior das lesões, de 1,9 quando o efeito acústico foi sombra, de 25,0 vezes quando houve o halo ecogênico e de 7,1 vezes quando a orientação foi não paralela. CONCLUSÕES: dentre as características estudadas, o limite da lesão, representado pela presença ou não do halo ecogênico, é o mais importante diferenciador das massas benignas das malignas.
Resumo:
PURPOSE: To evaluate changes to the pelvic floor of primiparous women with different delivery modes, using three-dimensional ultrasound. METHODS: A prospective cross-sectional study on 35 primiparae divided into groups according to the delivery mode: elective cesarean delivery (n=10), vaginal delivery (n=16), and forceps delivery (n=9). Three-dimensional ultrasound on the pelvic floor was performed on the second postpartum day with the patient in a resting position. A convex volumetric transducer (RAB4-8L) was used, in contact with the large labia, with the patient in the gynecological position. Biometric measurements of the urogenital hiatus were taken in the axial plane on images in the rendering mode, in order to assess the area, anteroposterior and transverse diameters, average thickness, and avulsion of the levator ani muscle. Differences between groups were evaluated by determining the mean differences and their respective 95% confidence intervals. The proportions of levator ani muscle avulsion were compared between elective cesarean section and vaginal birth using Fisher's exact test. RESULTS: The mean areas of the urogenital hiatus in the cases of vaginal and forceps deliveries were 17.0 and 20.1 cm², respectively, versus 12.4 cm² in the Control Group (elective cesarean). Avulsion of the levator ani muscle was observed in women who underwent vaginal delivery (3/25), however there was no statistically significant difference between cesarean section and vaginal delivery groups (p=0.5). CONCLUSION: Transperineal three-dimensional ultrasound was useful for assessing the pelvic floor of primiparous women, by allowing pelvic morphological changes to be differentiated according to the delivery mode.