137 resultados para Tissue implantation
Resumo:
Mitral valvuloplasty is efficient for repairing mitral valve disease with few complications. In some cases, obstruction of the left ventricular outflow tract may occur due to systolic anterior motion of the mitral valve. We report the case of a patient with this complication and a pressure gradient between the left ventricle and the aorta of 130 mm Hg after mitral valvuloplasty with implantation of a Gregori's ring. The management was clinical with suspension of the vasoactive drugs and introduction of a beta-blocker. Two years after the surgery, the patient is asymptomatic and has a normal life.
Resumo:
OBJECTIVE: Doppler tissue imaging (DTI) enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male) with ages ranging from 12 to 59 years (32.9 ± 10.6). Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation) of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls) were respectively, in cm/s, 7.35(1.64), 5.26(1.88), and 3.33(1.58) in systole and 10.56(2.34), 7.92(2.37), and 3.98(1.64) in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms), and diastolic was 459.18ms (±18.13ms) based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05). The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.
Resumo:
An atherosclerotic aneurysm of the right coronary artery complicated by a recent myocardial infarction was successfully treated with coronary artery stenting, using a device consisting of 2 stents with a layer of expandable polytetrafluorethylene (PTFE) placed between them. A follow-up angiograph 5 months after the procedure showed sustained initial results.
Resumo:
OBJECTIVE: To assess coronary stent placement in patients with multivessel coronary disease and involvement of the proximal portion of the anterior descending coronary artery. METHODS: We retrospectively analyzed the in-hospital and late evolution of 189 patients with multivessel coronary disease, who underwent percutaneous coronary stent placement. These patients were divided into 2 groups as follows: group I (GI) - 59 patients with involvement of the proximal segment of the anterior descending coronary artery; and group II (GII) - 130 patients without involvement of the proximal segment of the anterior descending coronary artery. RESULTS: No significant difference was observed in the success rate of the procedure (91.5% versus 97.6%, p=0.86), nor in the occurrence of major adverse cardiac events (5.1% versus 1.5%, p=0.38), nor in the occurrence of major vascular complications (1.7% versus 0%, p=0.69) in the in-hospital phase. In the late follow-up, the incidence of major adverse cardiac events (15.4% versus 13.7%, p=0.73) and the need for new revascularization (13.5% versus 10.3%, p=0.71) were similar for both groups. CONCLUSION: The in-hospital and late evolution of patients with multivessel coronary disease with and without involvement of the proximal segment of the anterior descending coronary artery treated with coronary stent placement did not differ. This suggests that this revascularization method is an effective procedure and a valuable option for treating these types of patients.
Resumo:
OBJECTIVE: To assess the usefulness of Doppler tissue imaging (DTI) for evaluating the systolic function of chagasic patients with and without electrocardiographic abnormalities, in comparision with echocardiographic study. METHODS: We studied 77 patients divided into 3 groups as follows: group 1 - control; group 2 - chagasic patients with normal electrocardiographic findings; and group 3 - chagasic patients with abnormal electrocardiographic findings. The following parameters were assessed: left ventricular dimensions and ejection fraction, left atrial dimensions and diastolic function on echocardiography. Systolic velocity and regional isovolumic contraction time (IVCTr) of the septal, anterior, lateral, posterior and inferior left ventricular walls were assessed on DTI. RESULTS: Left ventricular cavitary dimensions, ejection fraction and DTI systolic wave showed significant differences between groups 1 and 3 and between groups 2 and 3, which were not found between groups 1 and 2. IVCTr allowed a statistically significant discrimination among the 3 groups. CONCLUSION: DTI allowed discrimination among the different groups assessed, being superior to echocardiography in identifying early abnormalities of contractility, and, therefore, potentially useful for detecting incipient myocardial alterations in chagasic patients with normal electrocardiographic findings.
Resumo:
OBJECTIVE: To assess the in-hospital evolution of patients undergoing percutaneous stent placement in the carotid arteries. METHODS: From August 1996 to April 2001, we studied 86 patients with carotid arterial obliterative lesions > 70% who were treated with percutaneous stent placement in the carotid arteries. We assessed the rate of success of the implantation and of the procedure, the types of stents used, mortality rate, and neurological complications. RESULTS: Successful implantation was obtained in 98.9% of the cases, and the procedure was successful in 91.8%. The Wallstent was the most frequently used stent (73 patients - 77%). Cerebral strokes occurred as follows: 3 (3.2%) transient ischemic attacks, 1 (1.1%) minor stroke, and 3 (3.1%) major strokes. One (1.1%) patient died during hospitalization. CONCLUSION: The high rate of success of stent implantation (98.9%) in addition to the low rate of cerebral stroke/death (4.2%) showed the efficiency and safety of percutaneous stent placement in carotid arteries.
Resumo:
OBJECTIVE:To verify the influence of moderate- or high-pressure balloon inflation during primary coronary stent implantation for acute myocardial infarction. METHODS: After successful coronary stent implantation, 82 patients were divided into 2 groups according to the last balloon inflation pressure: group 1 (³12 to <16 atm) and group 2 (³16 to 20 atm), each with 41 cases. All patients underwent late coronary angiography. RESULTS: In group 1, the mean stent deployment pressure was 13.58±0.92 atm, and in the group 2 it was 18.15±1.66 atm. Stents implanted with moderate pressures (³12 to <16 atm) had a significantly smaller postprocedural minimal lumen diameter, compared to with those with higher pressure, with lesser acute gain (2.7± 0.4 mm vs 2.9±04 mm; p=0.004), but the late lumen loss (0,9±0,8 mm vs 0,9±0,6 mm) and the restenosis (22% vs. 17.1%) and target-vessel revascularization rates (9.8% vs 7.3%) were similar between the groups. CONCLUSION: During AMI stenting, the use of high pressures (³16 atm) did not cause a measurable improvement in late outcome, either in the late loss, its index, and the net gain, or in clinical and angiographic restenosis rates.
Resumo:
OBJECTIVE: To characterize left ventricular regional myocardial function through tissue Doppler echocardiography in healthy adults and to assess the influence of aging in this function. METHODS: In 45 healthy volunteers divided in two groups (< 45 and > 45 years old) we assessed longitudinal and radial regional function (velocities, times intervals and velocity-time integrals). Data were compared in each group and between groups. RESULTS: Systolic function: a) longitudinal: higher velocities and integrals in lateral and inferior walls and in basal segments, with a trend to reduction of these parameters with aging; b) radial: higher basal velocities, no significant change with aging. Diastolic function: a) longitudinal: higher velocities in lateral and inferior walls and in basal segments. With aging e and e/a velocities and integrals decreased, a increased and older individuals showed lower percentage of segments with e/a >1; b) radial: aging was associated with lower e and higher a velocities. CONCLUSION: 1) Tissue Doppler echocardiography detects physiological differences between regional myocardial function of different ventricular segments, in velocities, times intervals and integrals, with physiological heterogeneity and asynchrony; 2) Many of these data are age dependent; 3) Our data contribute to define normal values, and may become useful when compared with data from populations with heart diseases.
Resumo:
OBJECTIVE: To analyze the predictive factors of complications after implantation of coronary stents in a consecutive cohort study. METHODS: Clinical and angiographic characteristics related to the procedure were analyzed, and the incidence of major cardiovascular complications (myocardial infarction, urgent surgery, new angioplasty, death) in the in-hospital phase were recorded. Data were stored in an Access database and analyzed by using the SPSS 6.0 statistical program and a stepwise backwards multiple logistic regression model. RESULTS: One thousand eighteen (mean age of 61±11 years, 29% females) patients underwent 1,070 stent implantations. The rate of angiographic success was 96.8%, the rate of clinical success was 91%, and the incidence of major cardiovascular complications was 7.9%. The variables independently associated with major cardiovascular complications, with their respective odds ratio (OR) were: rescue stent, OR = 5.1 (2.7-9.6); filamentary stent, OR = 4.5 (2.2-9.1); first-generation tubular stent, OR = 2.4 (1.2-4.6); multiple stents, OR = 3 (1.6-5.6); complexity of the lesion, OR = 2.4 (1.1-5.1); thrombus, OR = 2 (1.1-3.5). CONCLUSION: The results stress the importance of angiographic variables and techniques in the risk of complications and draw attention to the influence of the stent's design on the result of the procedure.
Resumo:
OBJECTIVE: To assess the in-hospital results and clinical follow-up of young patients (< 50 years) with multivessel coronary artery disease undergoing stent implantation in native coronary arteries and to compare their results with those of patients with single-vessel coronary artery disease. METHODS: We retrospectively studied 462 patients undergoing coronary stent implantation. Patients were divided into 2 groups: group I (G-I) - 388 (84%) patients with single-vessel coronary artery disease; and group II (G-II) - 74 (16%) patients with multivessel coronary artery disease. RESULTS: The mean age of the patients was 45±4.9 years, and the clinical findings at presentation and demographic data were similar in both groups. The rate of clinical success was 95% in G-I and 95.8% in G-II (P=0.96), with no difference in regard to in-hospital evolution between the groups. Death, acute myocardial infarction, and the need for myocardial revascularization during clinical follow-up occurred in 10.1% and 11.2% (P=0.92) in G-I and G-II, respectively. By the end of 24 months, the actuarial analysis showed an event-free survival of 84.6 % in G-I and 81.1% in G-II (P=0.57). CONCLUSION: Percutaneous treatment with coronary stent implantation in young patients with multivessel disease may be safe with a high rate of clinical success, a low incidence of in-hospital complications, and a favorable evolution in clinical follow-up.
Resumo:
Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.
Resumo:
Systemic arterial hypertension (SAH) is considered to be the greatest risk factor for the development of neuro-cardiovascular pathologies, thus constituting a severe Public Health issue in the world. The Low-Level Laser Therapy (LLLT), or laser therapy, activates components of the cellular structure, therefore converting luminous energy into photochemical energy and leading to biophysical and biochemical reactions in the mitochondrial respiratory chain. The LLLT promotes cellular and tissue photobiomodulation by means of changes in metabolism, leading to molecular, cellular and systemic changes. The objective of this study was to analyze the action of low-level laser in the hemodynamic modulation of spontaneously hypertensive rats, in the long term. Animals (n = 16) were randomly divided into the Laser Group (n = 8), which received three weekly LLLT irradiations for seven weeks, and into the Sham Group (n = 8), which received three weekly simulations of laser for seven weeks, accounting for 21 applications in each group. After seven weeks, animals were cannulated by the implantation of a catheter in the left carotid artery. On the following day, the systemic arterial pressure was recorded. The Laser Group showed reduced levels of mean blood pressure, with statistically significant reduction (169 ± 4 mmHg* vs. 182 ± 4 mmHg from the Sham Group) and reduced levels of diastolic pressure (143 ± 4 mmHg* vs. 157 ± 3 mmHg from the Sham Group), revealing a 13 and 14 mmHg decrease, respectively. Besides, there was a concomitant important decline in heart rate (312 ± 14 bpm vs. 361 ± 13 bpm from the Sham Group). Therefore, laser therapy was able to produce hemodynamic changes, thus reducing pressure levels in spontaneously hypertensive rats.
Resumo:
AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.
Resumo:
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.